  • Premium

    Chemiluminescense based analyzer for industrial applications

    Focuses on medium NOx, NOx-related and multigas-concentrations up to 5’000 ppm where flexibility is a central requirement. Parameters included are NO, NO2, NOx, NH3, NOx-amines, O2 and CO2. Typical supported applications are industrial emission monitoring and gas manufacturing control.

    By ECO PHYSICS AG based in Duernten, SWITZERLAND.

  • Premium

    Choose high accuracy gas flowmeter for increased precision and profitability

    Sierra designs and manufactures a wide range of today’s most advanced analog and digital gas flowmeters and controllers, including a high-pressure gas flowmeter. For gas mixing and blending applications, accuracy and precision control and measurement are always a central requirement. Sierra’s precise flow meters and controls provide end-users with high performance in gas mixing and blending applications like creating artificial atmospheres, gas mixing in manufacturing, inerting and gas chromatography.

    By Sierra Instruments, Inc. based in Monterey, CALIFORNIA (USA).

  • Premium

    Carbon capture and storage (CCS) applications

    Carbon Capture and Storage (CCS) is an emerging method of reducing greenhouse gas (GHG) emissions of power plants. In a process called ‘scrubbing’, the carbon dioxide emissions can be absorbed into chemical solvents consisting of amines or carbonates. Scrubbing is a well-established method of carbon capture, with virtually every commercial CO2 capture plant in operation using this process. In the process, the first step is the removal of impurities from the flue gas, such as hydrocarbons and oxides of both nitrogen and sulfur (NOx and SOx). Next the purified gas is passed through an absorption column filled with the chemical scrubbing solvent. The solvent reacts with the carbon dioxide and selectively absorbs it from the gas stream. When CO2-rich solvent is heated, the carbon dioxide is released as a nearly pure gas.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Fluoride emissions monitoring in aluminum smelters

    Production of aluminum from its ores at aluminum smelters results in carbon dioxide CO2, carbon monoxide CO, sulfur dioxide SO2, and hydrogen fluoride HF gas emissions during the electrolytic process phase to the atmosphere. The gas emissions need to be monitored. Typically the smelters have emission limit values (ELVs) for sulfur dioxide and hydrogen fluoride emissions. These emissions should be measured accurately and with good precision, to ensure the smelter does not exceed its emission limit values. In addition several fluoride compounds may be produced in the electrolytic bath in the event of an oxygen shortage. These compounds include carbon tetrafluoride CF4, hexafluoroethane C2F6, sulfur hexafluoride SF6, and silicon tetrafluoride SiF4.

    By Gasmet Technologies Oy based in Helsinki, FINLAND.

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed sample volume is carried to the pre-cut column. Backflush of the pre-cut column is timed from sample injection so that only C1-C5 hydrocarbons are eluted from the pre-cut column to the analytical column. C6+ hydrocarbons on the pre-cut column are then vented.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Carbon dioxide mass flow meters flow solutions

    Thermal mass flowmeters are ideal for Carbon Dioxide metering and mass flow control. Sierra specializes in accurate mass flow measurement and/or control of CO2 gas. Applications range from general industrial process control across numerous industries to Green House Gas monitoring requirements and general research.

    By Sierra Instruments, Inc. based in Monterey, CALIFORNIA (USA).

  • Premium

    Measurement of vinyl chloride, acetaldehyde, methanol, and benzene in CO2 applicaitons for gas manufacturer & food and beverage industry

    The BevAlert Model 8900 provides direct measurement of Vinyl Chloride, Acetaldehyde, Methanol, and Benzene (VCAMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the AMB and other similar compounds continue on to the analytical column. Contaminants are then backflushed to vent. Acetaldehyde, Methanol, and Benzene are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Portable and fixed gas analysers for CO2 monitoring

    Monitoring industrial processes, CO2 gas quality control and indoor air quality can all be achieved using Geotech`s wide ranging CO2 analysers.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Portable and fixed gas analysers for incubator verification

    Geotech manufactures and supplies portable carbon dioxide monitors for use in incubator laboratories to verify CO2 in IVF and stem cell research applications.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Measurement of acetaldehyde, benzene, toluene, ethylbenzene, & xylenes in CO2 applications for food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Benzene, Toluene, Ethylbenzene, and Xylenes (ABTEX) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace volatile organic compounds in CO2 used in carbonated beverages.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Medical solutions for the oxygenators

    A number of components in a typical heart-lung machine require precise gas flow control. One typical component is the oxygenator, which is used for exchanging oxygen and carbon dioxide in the blood during surgical procedures. Axetris offers solutions for high-performance oxygen gas flow control in medical applications in the form of meters, controllers or gas mixing manifolds.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Premium

    Anaerobic water purification systems for aerobic COD removal

    In an aerobic treatment system, air is injected which is used by aerobic bacteria to convert BOD to carbon dioxide and water.

    By Paques B.V. based in EL Balk, NETHERLANDS.

  • Premium

    High quality gas sensor solutions for building and IAQ

    Precise measurement of air quality. The carbon dioxide content of room air gives a measure of the air quality, especially as it relates to the health and comfort of the people occupying the building. Air quality can be adversely affected by increased levels of carbon dioxide, carbon monoxide, volatile organic compounds (VOCs), particulates, or bacteria. Increased ventilation reduces the level of all of these unwanted contaminants. Measuring the CO2 concentration provides an economical way of ensuring that there is sufficient air circulation and prevents over-ventilation which can add unnecessary heating or cooling costs.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    High quality gas sensor solutions for biogas

    Fast, accurate and reliable measurement of CO2 and CH4 concentration. Methane and CO2 concentration measurements are a key part of the evaluation of the anaerobic digestion process. Too high or too low gas concentration levels can indicate a change in the efficiency of the fermentation process. AD process control systems measure the Methane content (and often the CO2 content) of the gas stream to control or evaluate the AD process and warn of problems. Edinburgh Sensors provide high performance OEM gas detectors that are able to give fast, accurate and reliable measurements of both CO2 and Methane concentrations.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    Carbon Monoxide and Carbon Dioxide Sensing for Gasification

    Application: Syngas (short for synthetic gas) can be burnt and used as a fuel source, the main constituents of syngas are Carbon Monoxide and Hydrogen, which amount for around 85% of Syngas, and it is produced by a process called Gasification.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    Methane and Carbon Dioxide Sensing for Biogas Applications

    Application: Anaerobic Digestion plants produce various gas components from a source material (or feedstock) that can be composed either solely or as a mixture of slurries, purpose-grown crops, food and organic waste material. The composition of the gas produced varies depending upon the feedstock and the Anaerobic digestion process itself. As a consequence, it is normal to measure various components of the resultant gas produced to evaluate the efficiency of the Anaerobic Digestion process. Furthermore, due to the flammable nature of Methane, and the risk of asphyxiation, most plants feature ambient air monitoring to protect personnel from any unplanned accumulation of leaked gas.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    Methane and Carbon Dioxide Sensing for Landfill Applications

    Application: In March 1986 an explosion destroyed a bungalow adjacent to a landfill site in Loscoe, Derbyshire. Subsequent measurements showed that 150-200 cubic meters of gas per hour were being generated by landfill waste. This event triggered a change in the way the waste industry considered and regulated gas generated at landfill sites; resulting in the landfill regulations of 2002, and in particular LFTGN03: the Guidance on the Management of landfill Gas.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    Process analyzers & instruments for CO/CO2

    By Ametek Process Instruments - THERMOX based in Pittsburgh, PENNSYLVANIA (USA).