Cascade Impactors Equipment For Monitoring And Testing Available In Comoros
-
PremiumManufactured by Dekati Ltd.based in FINLAND
70 mm filter stage holder with 2.5 μm ...
-
PremiumManufactured by Dekati Ltd.based in FINLAND
The DLPI+ (Dekati Low Pressure Impactor) is a 14-stage cascade impactor that is used to determine airborne particle mass size ...
-
PremiumManufactured by Dekati Ltd.based in FINLAND
The Dekati PM10 Impactor is a three-stage cascade impactor for determining particle gravimetric mass size distribution. The operating principle of the Dekati PM10 impactor is based on inertial size classification and gravimetric or chemical analysis of the collected, size classified particle samples. This impactor has cutpoints of 10, 2.5 and 1 μm making it an ideal choice for PM10, PM2.5 and ...
-
PremiumManufactured by Dekati Ltd.based in FINLAND
The HT-DLPI+ (High Temperature Dekati Low Pressure Impactor) is a 14-stage cascade impactor that is used to determine airborne particle mass size ...
-
PremiumManufactured by Dekati Ltd.based in FINLAND
The Dekati Gravimetric Impactor (DGI) is a high sample flow rate cascade impactor for low concentration particle measurement applications. The DGI measures gravimetric particle mass size distribution of particles < 2.5 μm in five size fractions. Typical measurement applications of the DGI impactor include engine emission measurements, air quality studies and other low concentration ...
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
Westech 8-stage non-viable cascade impactors are the result of many years experience in the design and manufacturing of similar devices. The team at Westech in collaboration with Dr Steve Nichols, then of Rhone Poulenc Rorer, were responsible for the design, configuration and validation of the 60 L/min and 90 L/min versions of the standard 28.3 L/min 8 stage impactor which has gained a ...
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
Designed specifically to improve efficiency, consistency and performance in inhaler testing laboratories, the semi-automated plate coater for Andersen Impactors from Novi coats plates as you wait. This plate coater can be modified to take NGI ...
-
Manufactured by TCR-Tecorabased in ITALY
MSSI impactor is realized according to ISO23210 norm for the nozzle dimensioning. The impactor allows the simultaneous determination of total dust, PM10 and PM2.5 fractions (PM4 stage also available). The impactor can be supplied with two different inlet cones to allow the vertical and horizontal sampling, depending on the stream direction into duct (fig. 1 and 2). The impactor is designed for a ...
-
Manufactured by Zefon International - Antylia Scientificbased in USA
Zefon high volume rotary vane pumps are an economical alternative to the Gast brand rotary vane pumps. The workhorses are heavy duty with a 1/10 hp motor that can be used for most all sampling applications. It can be used with PCM, TEM, Air-O-Cell and all viable impactors (e.g. Andersen style ...
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
Westech 7 is the newest innovation in impactor sampling technology, suitable for dry powder inhaler testing, metered dose inhaler testing, nebulizer testing & nasal spray testing. The W7 is a Seven Stage Cascade Impactor with Micro-Orifice Collector conforming to all the critical dimensions defined for USP Apparatus 5 & 6 and EP Apparatus E. The W7 is a multi-jet impactor with 8 removable ...
-
Manufactured by AMS Analiticabased in ITALY
Easy to use, the Dustcheck DPM-1 PM sampler fit with all sampling needs. Based with a powerful aspirating diaphragm pump (the EPA version has built in a single head diaphragm pump) that allows the system to perform sampling in a constant flow option to compensate any pressure drop coming from overload samples. The new microprocessor capabilities allow the user to select and store in the memory up ...
-
Manufactured by In-Tox Products, LLCbased in USA
In-Tox Products' Impactors are precision engineered and their careful design provides a number of advantages to the user. The material collected on each stage contains particles having sizes ranging from the cutoff size of the previous stage to the cutoff of the collecting size. Therefore, the analysis of the impactor data may be done without complicated computer programs. It also means that the ...
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
The Six Stage Bioaerosol Sampler is a cost effective, multi-stage, multi-orifice cascade impactor that measures concentration and particle size distribution of aerosol-type bacteria and fungi in the ambient air. Based on the inertial impaction principle, the six stage viable impactor collects all particles, regardless of physical size, shape, or density. The particles are aerodynamically sized in ...
-
Manufactured by Copley Scientific Ltdbased in UNITED KINGDOM
We offer a range of ancillary products required in addition to the dose collection device and cascade impactor to make up fully-operational systems for determining the Delivered Dose Uniformity (DDU) and Aerodynamic Particle Size Distribution (APSD) of orally inhaled and nasal drug products (OINDPs). View Our Inhaler Testing Brochure at: ...
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
Specifically designed for the larger laboratory, the Automated Plate Coater from Novi is capable of processing over 1000 Andersen Impactor collection plates per day with excellent consistency relieving analysts and technicians from time-consuming and inefficient manual coating, improving on both the productivity and the throughput of the more traditional approach. The Automated Plate Coater from ...
-
Manufactured by California Measurements, Inc.based in USA
10-stage QCM cascade impactor; covers particle size range of 10 to 0.05 microns; 2 lpm flow rate; complete with pump and control unit; provides printout of particle size distribution and mass concentration of ten size fractions automatically. Ideal for medium and lower concentration measurements down to a few ...
-
Manufactured by AMS Analiticabased in ITALY
The new high volume Air Flow PM10-HVS sampler line equipment perfectly complies with UNI-EN 12341 norm requirements for the respective sampling of PM-10 particles. It is equipped with an electronic flow control with a Venturi tube system in compliant with ISO 5167 requirements with differential pressure devices and for the detection of pressure itself on 4 points per sector, offering the user ...
-
Manufactured by TCR-Tecorabased in ITALY
MDI Metered Dose Inhalers; DPI Dry Powder Inhaler. Aerodynamic particle sizing. The design concept of the Andersen Cascade Impactor evolves from the following information: The human respiratory system tract is an aerodynamic classifying system for airborne particles. A sampling device can be used as a substitute for the respiratory tract as a collector of airborne particles, and as such, it shall ...
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
The 8-stage Andersen Cascade Impactor (ACI) is the most frequently used instrument for the testing of inhaler products within the Pharmaceutical Sector. Westech ACIs are specifically designed to meet the highest criteria laid down in the ...
-
Manufactured by InPharmaTEC, a TCR Tecora divisionbased in ITALY
A new cascade impactor has been designed for the OINDP Industry, specifically for pharmaceutical inhaler testing, and is the most efficient and accurate way to do standard in vitro APSD testing. The Impactor, called the Next Generation Impactor (NGI), has seven stages and is intended to operate at any inlet flow rate between 30 and 100 L/min. It offers a cut size (D50) spectrum spanning from 0.54 ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you