Conductivity Monitoring Applications in Florida
-
Premium
Hand-Held & Process Control Water Testing Instrument for Fountain Solutions
Accurate fountain (dampening) solution concentration control is essential for consistent, high-quality results in lithography. Low concentration can cause drying on the non-image area of the plate resulting in tinting, scumming, blanket piling, etc. High concentrations, on the other hand, bring about over-emulsification of the ink. This results in weakening of color strength and changes in ink rheology (body and flow properties). Correct concentration will allow the non-image areas of the plate to be appropriately ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
Bromate analysis for the drinking water industry
Bromate forms during the ozonization of drinking water. Several international standards stipulate detection limits and test methods. Conductivity detection with chemical suppression allows the determination of bromate in the lower μg/L range. In the ng/L range, bromate can be detected by IC/MS coupling or post-column derivatization with potassium iodide and subsequent UV ...
By Metrohm AG Distributor in Riverview, FLORIDA (USA).
-
Premium
Process water treatment
Process water covers the wide range of boiler feed water, cooling water for heat exchangers or engine, chemicals dilution, etc. It should typically have a conductivity ranging from 0,1 to 50 uS/cm, with little to no hardness to avoid scaling in heating system. Oxygen and carbon dioxide should be removed to prevent corrosion. Depending on your application, the water quality requirements can vary: Boiler feed water characteristic. Cooling water quality. Tap water or fresh groundwater are the most widely used source ...
By Lenntech Water Treatment Office in South Miami, FLORIDA (USA).
-
Premium
Ultra pure water treatment
Ultra pure water is mainly used in the semi conductor and pharmaceutical industry. Because of the continuing miniaturilisation in the semi conductor industry, the specifications become more strict every year. Ultra-pure water contains by definition only H20, and H+ and OH- ions in equilibrium. Therefore, ultrapure water conductivity is about 0,054 uS/cm at 25oC, also expressed as resistivity of 18,3 ...
By Lenntech Water Treatment Office in South Miami, FLORIDA (USA).
-
Premium
Emission control solutions for calcination and mineral processing sector
Calcination is a process that involves heating a substance, typically a solid material, at high temperature with limited supply of air or oxygen. The purpose of calcination is to remove volatile components and drive off impurities or to transform the material into a more desirable form for further ...
By Advanced Cyclone Systems, S. A. (ACS) Office in Tampa, FLORIDA (USA).
-
Premium
Water Data Management Solution for Groundwater Monitoring
Deployed across all relevant sectors including landfill security, well field monitoring programs, pumping tests, and drinking water supply, KISTERS solutions can be used to measure groundwater ...
By KISTERS Distributor in Lake Worth, FLORIDA (USA).
-
Premium
Oxidation Reduction Potential (ORP)/Redox
Oxidation Reduction Potential or Redox is the activity or strength of oxidizers and reducers in relation to their concentration. Oxidizers accept electrons, reducers lose electrons. Examples of oxidizers are: chlorine, hydrogen peroxide, bromine, ozone, and chlorine dioxide. Examples of reducers are sodium sulfite, sodium bisulfate and hydrogen sulfide. Like acidity and alkalinity, the increase of one is at the expense of the ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
ADVANCEES - Ultrapure Water Application - Custom skid-mounted water purification equipments
Ultrapure water (UPW) is water that has been purified to very strict specifications, containing by definition only H20, and H+ and OH- ions in equilibrium. Therefore, ultrapure water conductivity is about 0,055 uS/cm at 25oC, also expressed as resistivity of 18,2 MOhm. Ultra-pure water is mainly used in the semiconductor and pharmaceutical industry often is produced through processes like membrane filtration or ion exchange to reach the ultimate conductivity of 10 uS/cm. The demineralized water is then processed ...
By Advanced Equipment and Services, Inc based in Coral Springs, FLORIDA (USA).
-
Premium
Hand-Held & Process Control Water Testing Instrument for Deionized Water Testing Industry
Years ago, high purity water was used only in limited applications. Today, deionized (Dl) water has become an essential ingredient in hundreds of applications including: medical, laboratory, pharmaceutical, cosmetics, electronics manufacturing, food processing, plating, countless industrial processes, and even the final rinse at the local car ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
Water Testing for Automatic Rinse Tank Controls
Proper rinsing is one of the most important steps in quality manufacturing or metal finishing. Plenty of low cost, good quality water for rinsing has been available in the past, so rinse water conservation has been largely ignored. Today, this is no longer true. Tap water costs have increased dramatically. Various new regulations are now in effect which limit the allowable volume of wastewater. Others require wastewater treatment. Still other laws tax the amount of water going down the sewer. These factors have ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
Hand-Held & Process Control Water Testing Instrument for Environmental Industry
Keeping the water in our lakes, rivers, and streams clean requires monitoring of water quality at many points as it gradually makes its way from its source to our oceans. Over the years ever increasing environmental concerns and regulations have heightened the need for increased diligence and tighter restrictions on wastewater quality. Control of water pollution was once concerned mainly with treating wastewater before it was discharged from a manufacturing facility into the nation's waterways. Today, in many ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
pH value and conductivity measurement for power plants
Growing populations – about 80 million every year – and industrializing countries create huge needs for electrical energy. According to the International Energy Agency (IEA) the global energy demand will increase by about 65% by 2035. A major fraction of the required energy will continue to be provided by thermal – mainly fossil fuel-fired and nuclear – power plants. "Renewable" energy sources such as photovoltaics (PV) will be another backbone of our energy supply. Putting renewable energy ...
By Metrohm AG Distributor in Riverview, FLORIDA (USA).
-
Premium
Water Data Management Solution for Hydrometric Network Monitoring
Centralize your hydrometric network monitoring efforts with KISTERS solutions. They provide a complete range of tools to monitor surface water, groundwater, meteorological, and water quality ...
By KISTERS Distributor in Lake Worth, FLORIDA (USA).
-
Premium
Reverse Osmosis Water Testing
Osmosis is the phenomenon of lower dissolved solids in water passing through a semi-permeable membrane into higher dissolved solids water until a near equilibrium is reached. Reverse Osmosis (RO) is a membrane process of purification which removes most of the the total dissolved solids (TDS) in water by reversing the natural process of osmosis. Pressure is applied to a TDS-concentrated solution against a semi-permeable membrane, causing pure water to diffuse through the membrane. RO has become an important process ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
Hand-Held & Process Control Water Testing Instrument for Circuit Board Cleanliness Testing Industry
Contamination of circuit boards can bring about severe degradation of insulation resistance and dielectric strength. Cleanliness of completed circuit boards is, therefore, of vital interest. For those companies who have established circuit board cleaning procedures, the MIL Spec P-28809 has been used as a guideline for control. Now a simple 'on line' test for the relative measurement of ionic contamination has been developed. This fast and economical method for testing circuit board cleanliness uses a Myron L ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
Hand-Held & Process Control Water Testing Instrument for Boilers and Cooling Towers
Boilers and cooling towers share two major water related problems: deposits and corrosion. As steam is generated by a boiler or water evaporating from a cooling tower, dissolved minerals are left behind, increasing the concentration of these minerals. Additional minerals are introduced via the water added to makeup the water lost to steam/evaporation. Eventually, the minerals reach a level (or cycle) of concentration that will cause either loss of efficiency due to scale or damage from corrosion. This level can be ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Premium
Water Data Management Solution for Alpine Monitoring
KISTERS has developed a specific version of WISKI with unique benefits for those monitoring Alpine Regions. Some of its advanced features include specialized calculations for measuring precipitation, snow, sediment transport and water balances in ...
By KISTERS Distributor in Lake Worth, FLORIDA (USA).
-
Premium
Water Testing for Textile Manufacturing
The textile manufacturing industry encompasses many and diverse processes that rely heavily on the use of water, energy, chemicals, and other resources. Wet spinning, sizing, desizing, scouring, bleaching, mercerization, dyeing and printing are just a few. Monitoring and controlling the pH, TDS/Conductivity/Salt Concentration, ORP (REDOX), and Temperature of the aqueous solutions used in these processes conserves costly resources, controls quality, and reduces the amount of pollution that must be treated before ...
By Myron L Company Distributor in , FLORIDA (USA).
-
Measurement and control systems for the Limiting the level - electronically
A distinction is made between low water (LW) and high water (HW) limiters. Whereas LW limiters are in principle required for the safe operation of a plant in accordance with European regulations, HW limitation (overfill protection) is required only in accordance with TRD 604 for 72-hour ...
By IGEMA GmbH Office in Miami, FLORIDA (USA).
-
Measurement and control systems for the Boiler water monitoring
In ongoing operation, the substances suspended in the boiler water are concentrated. In order to avoid the negative consequences (foaming, deposits) of excessive salt content in the boiler water, specified limit values must not be exceeded. With the aid of a desalination control valve, boiler water with concentrated content is constantly removed and replaced with clean water. If the limit values are exceeded, the conductivity limitation ensures prompt switching off of the burner(s). Foreign substances that have ...
By IGEMA GmbH Office in Miami, FLORIDA (USA).
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you