dissolved oxygen measurement Articles

  • ppb Dissolved oxygen measurement

    Dissolved oxygen (D.O.) measurement is one indicator of water quality because oxygen is a common element contributing to corrosion reactions. This corrosion reaction provides the need for low level D.O. control since dissolved oxygen is responsible for costly replacement of piping and equipment by corrosive attack on metah. what is Dissolved Oxygen? Dissolved axygan (D.O.f is the ...


    By IC Controls Ltd.

  • ppm Dissolved oxygen measurement

    Dissolved oxygen (D.O.) levels are used as a general indicator of water quality. Oxygen is essential to life and vital for countless aquatic forms. D.O. level control is critical in numerous applications ranging from the monitoring of industrial waste water to environmental surveillance. What is Dissolved Oxygen? Dissolved oxygen (D.O.) is the amount of oxygen gas dissolved in a ...


    By IC Controls Ltd.

  • Dissolved oxygen’s effect on ecosystems

    Dissolved oxygen (DO) is a measure of the amount of oxygen dissolved in water. It can be caused by a process of aeration of water flowing through rapids or falls, a byproduct of photosynthesis and the atmosphere. Monitoring DO levels in water may be more important than you think. From dead fish washing up on the shores of Singapore, to historically low levels of brown shrimp, DO is having an ...


    By Aquaread Limited

  • Dissolved Oxygen – the discussion moves on

    Do Dissolved Oxygen Sensors need Cleaning? The re-emergence of Optical Dissolved Oxygen Sensors around 6-7 years ago generated a lively and interesting discussion which revolved around the relative merits of Optical and Galvanic Dissolved Oxygen sensors. We understand that opinions will differ, so in order to accommodate our customers preferences we are pleased to offer our OxyTechw² ...


    By Partech (Electronics) Ltd.

  • Boiler Dissolved Oxygen Control

    DISSOLVED OXYGEN CHEMISTRY Dissolved Oxygen (DO) is a measure of the amount of oxygen, usually thought of as a gas, that is dissolved in a liquid such as water. Oxygen is essential to life and is also the most common element found taking part in corrosion reactions. DO can be thought of as the fuel needed for the corrosion process to proceed. It is the corrosion reactions that necessitate ...


    By IC Controls Ltd.

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate ...


    By Partech (Electronics) Ltd.

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate measurements of Dissolved Oxygen in activated sludge plants for the following reasons: To ...


    By Partech (Electronics) Ltd.

  • Optical measurement of oxygen concentration in water

    The optimisation of oxygen transfer is a key element of control and regulation strategies in municipal and industrial sewage treatment plants. In 2003, HACH LANGE became the first instrument manufacturer to launch the LDO (Luminescent Dissolved Oxygen) method for determining dissolved oxygen in water. The LDO technology is based on pulsed blue light, which brings benefits such as high precision, ...


  • Dissolved oxygen measurements in aquatic environments: The effects of changing temperature and pressure on three sensor technologies

    Dissolved oxygen (DO) is probably the most important parameter related to water quality and biological habitat in aquatic environments. In situ DO sensors are some of the most valuable tools used by scientists and engineers for the evaluation of water quality in aquatic ecosystems. Presently, we cannot accurately measure DO concentrations under variable temperature and pressure conditions. ...

  • Continuous on-line monitoring of dissolved oxygen in the activated sludge of a sewage treatment plant

    Dissolved oxygen is traditionally measured using a Clark cell, which relies upon a gas-permeable membrane for its opera-tion. Such sensors are subject to fouling with subsequent loss of accuracy, making frequent maintenance and calibration necessary. The objective of this development was to take advantage of specific properties of microelectrode arrays, such as low flow-dependence, insensitivity ...


  • Product of the Month – Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger

    This month the focus is on the Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger. Over the summer months we have seen increased interest in the instrument. Warmer temperatures can affect the chemistry, biological processes and dissolved oxygen levels in water, making the Handy Polaris 2 a popular ...


    By Partech (Electronics) Ltd.

  • Prediction of dissolved oxygen in reservoirs using adaptive network-based fuzzy inference system

    Predicting water quality is the key factor in the water quality management of reservoirs. Since a large number of factors affect the water quality, traditional data processing methods are no longer good enough for solving the problem. The dissolved oxygen (DO) level is a measure of the health of the aquatic system and its prediction is very important. DO dynamics are highly nonlinear and ...


    By IWA Publishing

  • Measuring Short-Term BOD

    Measurement of oxygen uptake rates in activated sludge processes is essential to their satisfactory operation. Traditionally, oxygen uptake rates (OUR) have been determined by using a dissolved oxygen probe to measure the change in dissolved oxygen in a BOD bottle. While this method is rapid, it provides only a snapshot, at a single point in time, of the oxygen uptake rate reaction in a treatment ...


    By Challenge Technology

  • Theory to Practice: Oxygen Transfer and the New ASCE Standard

    ABSTRACTOxygen transfer is an important part of wastewater treatment and accounts for as much as 60% of the energy consumption for the activated sludge process. Prior to 1984, no standard method for quantifying oxygen transfer existed, which created problems in the design and warranties for treatment plants. The ASCE Standard for the Measurement of Oxygen Transfer in Clean Water and the ASCE ...

  • What are the differences between Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD)?

    Ask the expert: What are the differences between Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD)? Answer: Both COD and BOD test methods aim to give an indication of the amount of pollution in a water sample. COD is the amount of oxygen required to chemically breakdown the pollutants whereas BOD is the amount of oxygen ...


    By Camlab Limited

  • Energy Optimisation by Determination of Critical Oxygen Point in WWTP Operations

    The control of dissolved oxygen levels in Waste Water Treatment plants has been the subject of considerable technological improvement over the past 2 decades. Typically the energy required for aeration purposes in aerobic activated sludge plants is in the region of 35% to 65% of the total energy costs for the facility. On a global basis energy conservation is taking on greater and greater ...

  • Analysis of nitrogenous and algal oxygen demand in effluent from a system of aerated lagoons followed by polishing pond

    In this descriptive-analytical study, nitrogenous and algal oxygen demand were assessed for effluent from a system of facultative partially mixed lagoons followed by the polishing pond using 120 grab samples over 1 year. Filtered and non-filtered samples of polishing pond effluent were tested in the presence and absence of a nitrification inhibitor. Effective factors, including 5-day biochemical ...


    By IWA Publishing

  • AquaLab Analyzer provides real-time phosphorus measurement in Everglades

    When it comes to ecosystem sustainability, Florida is no backwater. The South Florida Water Management District, which includes the unique Everglades habitat, had a major challenge. The EPA and various governmental authorities have defined limits for many water quality parameters to support a water body’s designated use. Any physical, chemical or biological condition that threatens the designated ...

  • A method for on-line measurement of wastewater organic substrate oxidation level during aerobic heterotrophic respiration

    A method for on-line measurement of the organic carbon oxidation level (OXC) during aerobic heterotrophic respiration in domestic wastewater was developed and tested. The method is based on batch incubation of sewer wastewater in an intermittently aerated respirometric reactor. Between aeration cycles, measured pH, dissolved oxygen (DO) and dissolved carbon dioxide (CO2) were used to ...


    By IWA Publishing

  • Salinity and miniDOT

    The miniDOT and other optical dissolved oxygen sensors measure oxygen within a special plastic material that has the property of changing its fluorescence in response to the amount of oxygen present. Oxygen arrives within this material by diffusion from the surrounding environment, which is usually water.  The miniDOT determines oxygen concentration in water dissolved oxygen  by ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you