Emissions Sampling (Environmental Sampling) Equipment Available In Nepal
-
Manufactured by AMS Analiticabased in ITALY
. The backlit display shows all the quantities detected in real time and the relevant calculations for setting sampling devices and accessories. All the performed measurements and relevant data can be saved and downloaded to a PC through the external SDC software via RS232 and USB port. The Isoflow 202-Pro can be directly connected via RS232 with the ...
-
Manufactured by AMS Analiticabased in ITALY
It consists of a probe sampling device with a spout aimed in the opposite direction of the emission exhaust with a heated pre-filter to withhold any particles interfering with the sample (device provided for monitoring of SOx and NOx, SOV without heating). The StackGas 2001 probe is configured to allow the user easy sampling. It ...
-
Manufactured by TCR-Tecorabased in ITALY
The dividable monotube probes can be used in that application where isn’t possible or not convenient to use an integrated probe. Are developed in conformity with the “Determination of dust concentration at low concentrations” according to the EN 13284-1. The Method in the In-stack filter sampling line describe a particular ...
-
Manufactured by TCR-Tecorabased in ITALY
Kit to use the 47mm inox steel or titanium filterholder in the heated box. Using this kit, composed by two adapters, it’ possible to use the filterholder for 47mm flat membranes (see Emission Line 1.104.01) placing it in the heated box of the probe for micropollutants. The front connector fit to the outlet of the probe while the ...
-
Manufactured by TCR-Tecorabased in ITALY
X-TDP (Twin Dilution Probe) is the last frontier of the gas sampling in stationary source emissions and process! Born from experience in the field and with the help of whom daily, it is faced with the need to operate with equipment that simplifies the collection of gas and allow to carry out several activities at the same time. ...
-
Manufactured by TCR-Tecorabased in ITALY
The dividable monotube probes can be used in that application where it is not possible or not convenient to use an integrated probe. They are developed in conformity with the “Determination of dust concentrations” according to UNI EN 13284-1. It is also compatible with all TCR Tecora filter holder device.The connection and the extension tubes are the ...
-
Manufactured by TCR-Tecorabased in ITALY
Our isokinetic probes are realized to make the sampling easier by placing the probe more precisely in the stack emission flow during isokinetic ...
-
Manufactured by TCR-Tecorabased in ITALY
Condensing and adsorbing device MCS2 for the determination of PCDD/PCDF in compliance to EN 1948 Method. The EN 1948-1 “Filter condenser” method foresee the isokinetic sampling with a heated probe, filterholder and adsorbing trap XAD2/PUF after the ...
-
Manufactured by TCR-Tecorabased in ITALY
Condensing and Adsorbing Device EPAMCS2 for the Determination of PCDD/PCDF in Compliance to EPA 23 and EN 1948 Method. The EPA 23 and EN 1948-1 methods foresee the isokinetic sampling line with a heated probe, filterholder and XAD2 adsorbing trap for both gas and ...
-
Manufactured by TCR-Tecorabased in ITALY
Isokinetic sampling kit with filter holder for flat d. 47 mm ...
-
Manufactured by TCR-Tecorabased in ITALY
In-stack filter application curve and interchangeable nozzles according to ISO 9096 and EN 13284. The drawing of this curve is in accordance with the international laws in force regarding isokinetic sampling. It is entirely made of either INOX 316 or titanium and is compatible with all TCR Tecora filter holder and probes equipped with cone ...
-
Manufactured by TCR-Tecorabased in ITALY
Our isokinetic probes are realized to make the sampling easier by placing the probe more precisely in the stack emission flow during isokinetic ...
-
Manufactured by TCR-Tecorabased in ITALY
More and more standards forced stack emission testers to adapt their equipment and the necessary devices to carry out correct pollutants sampling activity. Cooling-condensed molecules presence in the exhausts makes it necessary to heat the probe and all the connected devices. All the materials used therefore have to guarantee ...
-
Manufactured by Emproco Ltdbased in ISRAEL
The SKC AirChek TOUCH air sampling pump is the first personal sample pump with color touch screen navigation. Ultra-quiet and tough AirChek TOUCH provides extended flows from 5 to 5000 ml/min and high back pressure compensation for all your IH applications. Programming continuous, timed, and intermittent sampling is easy -- no instruction ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Method 7C (Colorimetric) and 7D (Ion Chromatography) are used for the determination of nitrogen oxide emissions. A sample is passed through a series of specially built impinger that contains an alkaline potassium permanganate solution. The impingers are of standard height with a narrow bottle, which improves the collection efficiency. The ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments Method 17 Isokinetic Sampling System, featuring the XC-53 metering console, is ideal for collecting and determining in-stack particulate emissions from a wide variety of sources. Particulate emissions are commonly sampled from coal-fired power plants, cement kilns, asphalt plants, incinerators and ...
-
Manufactured by Kurz Instruments, Inc.based in USA
Kurz offers a complete isokinetic sampling system to ensure true sample composition — from stack flow monitoring and sample capture to sample flow control. The Kurz Emissions and Sampling System provides accurate sample collection for environmental, process, and nuclear ...
-
Manufactured by Starna Scientific Ltd.based in UNITED KINGDOM
Four polished windows, with windows opposite the emission and excitation windows mirrorcoated to increase performance. Type 19.05F/L is a patented design with integral lens primarily designed for use with small cross section focussed beam instruments. The lens colimates the emission energy leaving the sample chamber onto the detector. ...
-
Manufactured by Texas Sampling, Inc.based in USA
Texas Sampling's Manual Continuous sample system is a closed loop liquid sampler that satisfies many sampling needs. This system will take emission free, representative samples of process while providing operator safety. Our patented valve design ensures zero dead volume throughout the sample ...
-
Manufactured by TCR-Tecorabased in ITALY
into duct (fig. 1 and 2). The impactor is designed for a high sampling flowrate, about 2 m3/h, depending on emission characteristics, to reduce sampling time. The device is supplied with a dedicated software, which allows to calculate sampling flowrate, nozzle and others factors to optimize the quality of the measurement. The ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you