Isokinetic Sampling (EPA Methods) Equipment
-
PremiumManufactured by Apex Instruments, Inc.based in USA
EPA Method 4 is used to determine the moisture content of stack gases. A gas sample is extracted at a constant rate from the source. Moisture is then removed from the sample stream and the condensate is measured either by volume or by ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments Compact Method 23 sampling system is utilized for US EPA Method 23 Determination of Dioxins and Furans from stationary sources. Dioxins and furans are an unwanted by-product of combustion processes such as municipal and industrial waste, wood and oil ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments PFAS Sampling System is based on the EPA Other Test Method 45 (OTM-45) and Other Test Method 50 (OTM-50) for the isokinetic collection of PFAS from stationary sources. PFAS stands for per- and polyfluoroalkyl chemicals, which are found in a wide range of consumer products and facilities. PFAS can accumulate in the body and ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments Model XC-523 is a full-feature manual meter console. Designed with a convenient display layout for manual data recording, this Isokinetic XC-523 Source Sampling Console allows the operator to monitor gas velocities, temperatures, and pressures and adjust sample flow rates to maintain isokinetic ...
-
Manufactured by CleanAir Europebased in FRANCE
CleanAir Europe offers the CleanAir CATECO Isokinetic Sampling System which is identical to the Method 5 sampling system, the difference being the replacement of the modular sample filtration system with a more versatile CATECO heated filter unit. Separating the probe and the filtration unit from the glassware makes it easier to ...
-
Manufactured by CleanAir Europebased in FRANCE
CleanAir offers a manual isokinetic sampling system for continuous sampling of gases or vapours from a stack with the same velocity characteristics as at the sampling point. The particles are deposited on a filter. Hot gases are conditioned in a series of cold bubblers. Condensate is recovered and a volumetric gas meter (DGM) ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Pre-programmed Method 5 Casio Calculator. The programmed isokinetic calculator serves as a replacement for the nomograph, or slide-rule calculator, to calculate isokinetic conditions for EPA Method 5 and EPA Method 5-type sampling. The calculator is developed to be accurate and simple to ...
-
Manufactured by Eonair Technologies Pvt Ltd.based in INDIA
Our Method 23 Source Sampler Kit is utilized for Method 23 Determination of Dioxins and Furans (D/F’s) and/or Method 0010 Determination of Semi-Volatile Organic Compounds. The sampling train is identical to the standard Method 5 system with the addition of a water-cooled glass condenser and an XAD absorbent module followed by a ...
-
Manufactured by Protea Limitedbased in UNITED KINGDOM
The CP5 is a modern version of the classic unheated cold sample probe for the isokinetic sampling of particulate matter in stack emissions. The CP5 design and construction follow the philosophy of being easy and practical to use on the stack. The CP5 is fully realized in AISI316 and is supplied including the AISI316 inner tube, ...
-
Manufactured by Protea Limitedbased in UNITED KINGDOM
The HP5 heated sampling probe is ideal for the determination of particulate matter and chemicals in the gas phase.Its unique design, combined with the clamps-free slide and lock device, allows the probe to freely rotate around its axis, which is needed for the swirl angle determination in accordance with the EN16911 and US EPA M1/2 ...
-
Manufactured by TCR-Tecorabased in ITALY
Condensing and Adsorbing Device EPAMCS2 for the Determination of PCDD/PCDF in Compliance to EPA 23 and EN 1948 Method. The EPA 23 and EN 1948-1 methods foresee the isokinetic sampling line with a heated probe, filterholder and XAD2 adsorbing trap for both gas and ...
-
Manufactured by Felix Technology Inc.based in CANADA
isokinetic sampling conditions. For sampling to be isokinetic the sample gas enters the nozzle at a velocity equal to the approaching gas velocity. All Apex Instruments models are interchangeable and compatible with most others currently in use. Our 572 Series Consoles are equipped with Metric instruments and ...
-
Manufactured by Aer Sampling Inc.based in USA
Aer Sampling’s Borosilicate Glass Probe Liner for isokinetic sampling. Best suited for applications requiring a high stack temperature of up to 932 ºF (500 ºC). Probe Liner is the surface that actually comes into contact with the flue gas sampled from the smoke-stacks/chimneys. It is frequently used together with ...
-
Manufactured by AMS Analiticabased in ITALY
samplers (HE and COM2TH), allowing the user to perform a real time isokinetic sampling in compliance with ISO-9096 protocol. A self-drive easy menu enables the user to display all the data that were entered and stored at that time as well as the changes made during sampling as ...
-
Manufactured by Aer Sampling Inc.based in USA
This assembly consists of an MKORTM Heater Box (Hot Box) and a Box Extender (Riser Box)—used in Aer Sampling's US EPA Method 5 Standard Configuration sampling train. In this configuration, an Impinger Box (Cold Box) can be attached to the Riser Box for your sampling convenience. Furthermore, the boxes are modular, allowing you to ...
-
Distributed by ENCO LTDbased in GREECE
ENCO offers a complete range of off-line sampling equipment for dust and gaseous emissions. They are all instruments operating with standard reference methods (EN, ISO and US EPA methods) and are used for periodic measurements according to the environmental legislation, spot measurements or for calibration of continuous emission ...
-
Manufactured by Polltech Instruments Pvt. Ltd.based in INDIA
Gaseous and particulate pollutants are withdrawn isokinetically from the source and collected on a filter and in absorbing solutions. The filter collects particulate matter including halide ...
-
Manufactured by Polltech Instruments Pvt. Ltd.based in INDIA
Gaseous and particulate pollutants are withdrawn isokinetically from the source and collected on a filter and in absorbing solutions. The filter collects particulate matter including halide ...