Flame Ionization Detection Applications

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methane, methanol and ethanol for the biomass monitoring for biofuels.

    The Series 8900 provides direct measurement of methane, methanol, and ethanol for the biofuel industry. The Series 8900 GC employs a flame ionization detector (FID). The methane, methanol, and ethanol in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and heavier gases. At sample injection, a fixed volume of sample is carried through the pre-cut column. The backflush is timed so that primarily the MME and...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of methyl ethyl ketone, chloroform & carbon tetrachloride in air for remediation & super fund sites

    The Series 8900 Analyzer provides direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride in ambient air. This instrument is utilized for remediation and Super Fund sites and to monitor workplace exposure limits.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Online monitoring solutions for the determination of chlorinated organics in water

    Determining chlorinated organics in waste water of the oxychlorination process is for reasons of environmental compliance. The on-line analyzer system uses a scrubber system where a carrier flow is bubbling through the water. The vapor phase is measured by a Flame Ionization Detector (FID) and is a measure for chlorinated organics of the water.

    By AppliTek NV based in Nazareth, BELGIUM.

  • Gas detection analyzers for chemical & pharmaceutical processes

    Chemical and pharmaceutical facilities use a variety of hazardous gases and solvents in their production processes. Whenever these substances are transported, processed or stored, the potential risks are high for hazardous conditions. These substances must be continuously monitored to protect personnel and facilities from accidental releases or leakage. Our various lines of hazardous gas monitoring systems benefit the chemical and pharmaceutical industry in the following applications.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).

  • Gas detection analyzers for pollution control

    Government and environmental groups are forcing industries with medium to high VOC exhausts to reduce emissions by as much as 98%. Incineration using pollution control devices such as oxidizers and flare stacks is one way to bring the exhaust emissions in line with the regulations. Capturing and reusing solvent in a solvent recovery system is another way.

    By Control Instruments Corporation based in Fairfield, NEW JERSEY (USA).