Only show results available in Virginia? Ok

Gas Calibration Applications

  • Premium

    Capabilities of the Adsorbent Tube Injector System (ATIS™)

    The Adsorbent Tube Injector System (ATIS) was developed at Supelco® by R&D Scientists, as a tool to assist in our comprehensive adsorbent research for thermal desorption tubes. The ATIS provides an efficient means of transferring calibration standards in either the gas or liquid phase onto the adsorbent packed tubes. The ATIS employs the technique of flash vaporization to vaporize the sample in a continuous flow of inert gas; the inert gas carries the sample to the tube. The sample pathway of the ATIS is construct...

    By Merck KGaA, Darmstadt, Germany based in Darmstadt, GERMANY.

  • Premium

    Measurement of C1-C5 with carbon dioxide for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons and Carbon Dioxide required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    BTEX in Ambient Air Application using a High-Sensitivity PID

    The Series 8900 BTEX Analyzer with a high-sensitivity PID provides direct low level measurement of Benzene, Toluene, Ethylbenzene, and Xylene`s in ambient air. This instrument is utilized in ambient air networks around metropolitan areas and fence-line monitoring at industrial sites.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Total sulfur measurement for sulfur compounds in CO2 for food & beverage industry

    The BevAlert Model 8900 provides a total sulfur measurement for sulfur compounds in Carbon Dioxide. The measurement includes organic sulfides, Sulfur Dioxide, Carbonyl Sulfide, and Hydrogen Sulfide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor sulfur compounds in CO2 used in carbonated beverages.

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of acetaldehyde, methanol, & benzene in CO2 applications for gas manufacturers & food & beverage industry

    The BevAlert Model 8900 provides direct measurement of Acetaldehyde, Methanol, and Benzene (AMB) in Carbon Dioxide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor trace impurities in CO2 used in carbonated beverages. The BevAlert Model 8900 employs a photoionization detector (PID). The AMB in the gas sample are physically separated using proprietary GC columns. A dual-column configuration with timed backflush to vent is used to strip off moisture and...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of C1-C5 hydrocarbons for oil & gas exploration.

    The PetroAlert Model 8900 combines the selectivity of gas chromatography with the sensitivity, broad dynamic range, and hydrocarbon selectivity of a flame ionization detector (FID) providing fast analysis of C1-C5 hydrocarbons required in Mud Logging for Oil & Gas exploration. The PetroAlert Model 8900 uses a dual column configuration with timed backflush to vent which is used to strip off moisture and C6+ hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas monitoring instruments and systems for HAZMAT

    Accidents involving chemicals and other hazardous materials require fast and accurate gas measurements as part of the first response. The Gasmet™ DX4040 portable FTIR Gas Analyzer provides reliable identification and concentration measurements of hazardous gases in 60 seconds or less.

    By Gasmet Technologies Oy based in Vantaa, FINLAND.

  • Premium

    Measurement of acrylonitrile in ambient air for monitoring workplace exposure limits

    The Series 8900 Acrylonitrile Analyzer provides direct measurement of Acrylonitrile in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Acrylonitrile Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of diacetyl in ambient air to monitor workplace exposure limits.

    The Series 8900 Diacetyl Analyzer provides direct measurement of Diacetyl in ambient air. This instrument is utilized for environmental monitoring and to monitor workplace exposure limits. The Series 8900 Analyzer for Diacetyl employs a photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Gas monitoring instruments and systems for fumigation

    Sea cargo containers and wooden packing materials are fumigated to control the spreading of pest animals and micro-organisms. Fumigant gases are toxic and measurements are carried out as a health and safety precaution. Measurements are required by e.g. customs inspectors prior to opening containers, making the shipping companies responsible for carrying out measurements. Products shipped in containers may release VOCs from e.g. solvents and glues used in manufacturing process. The concentrations of vapors may be...

    By Gasmet Technologies Oy based in Vantaa, FINLAND.

  • Premium

    Gas calibration for laboratories

    By Umwelttechnik MCZ GmbH based in Bad Nauheim, GERMANY.

  • Premium

    Measurement of formaldehyde in ambient air for monitoring workplace exposure limits

    The Series 8900 Formaldehyde Analyzer provides direct measurement of Formaldehyde in ambient air. This instrument is utilized in industrial plants to monitor workplace exposure limits. The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is...

    By AMETEK MOCON - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Methane Sensing for Coal Mining

    Application: The majority (around 60%) of the coal seams currently being extracted worldwide are so far underground that open cast mining cannot take place and, therefore, underground mining techniques need to be used. Consequently, workers have to enter and work in confined spaces. One of the major problems that this creates is the dangers from Methane (CH4) gas which occurs in Mine gas.

    By Edinburgh Sensors Ltd based in Livingston, UNITED KINGDOM.

  • Premium

    Continuous emissions monitoring for brick plants

    Process control and emissions monitoring in a brick plant is a challenge due to the high concentrations of HF. The HF is generated in the process and gas phase HF can reach 50 mg/m3 or more. To use an extractive system in this environment will demand a lot of maintanence.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for cement industry

    Process control and emissions monitoring in cement plants, can be a challenge due to the dusty and corrosive environment. OPSIS provides an accurate system that will operate with high performance and a minimum of maintenance.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for glass manufacturing industries

    Process control and emissions monitoring in a glass manufacturing plant is a challenge due to high temperature in the flue gas. The OPSIS DOAS system provides the glass industry with an accurate analyser that will operate with a minimum of maintenance. The OPSIS DOAS system is based on a non-contact method that uses an optical path to measure across the duct. A single OPSIS system will measure all relevant gas componensts such as NOX, SO2, CO, CO2, H2O, O2, and others.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Ambient air quality monitoring solutions for benzene fence-line monitoring

    To monitor benzene emissions can be a challenge, but OPSIS makes it easy. Benzene is an aromatic hydrocarbon liquid that evaporates quickly if exposed to ambient air. It is one of the most commonly used substances in the chemical industry and it is known to cause cancer. For this reason, refineries in the United States must start monitoring fugitive emissions of benzene from January 30, 2018. This is part of the 2015 U.S. EPA Petroleum Refinery rule. In case a yearly rolling average of benzene concentrations...

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for mining & smelting

    OPSIS non-contact monitoring solutions, based on either DOAS or TDL techniques, are very well suited for applications in the mining and smelting Industries, as the flue gas conditions often involve high temperatures and high dust concentrations.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Ambient air quality monitoring solutions for tunnel monitoring

    Car tunnels need ventilation in order to keep air pollution below the limits. When the pollution levels reaches a setpoint, the fans must be started and kept running until the pollution levels decreases.

    By Opsis AB based in Furulund, SWEDEN.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you