Only show results available in Virginia? Ok

Hydrogen Sulfide (H2S) Monitoring Applications

  • Hydrogen Sulfide (H2S) monitoring

    Hydrogen sulfide is the chemical compound with the formula H2S. H2S is colorless, toxic and flammable and is responsible for the foul odour of rotten eggs and flatulence. Hydrogen sulfide often results from sulfur reducing bacteria in nonorganic matter (in the absence of oxygen), such as in swamps and sewers (anaerobic digestion). H2S also occurs in volcanic gases, natural gas and some well waters.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Aqua M300 Intelligent Geophone

    With the Aqua M300 leak detectors have a multifunctional tool to Pinpoint or Pre-locate leakages and to trace pipes in conjunction with a PWG. The biggest advantage compared to other related products are the 256 analogue and digital filters which enables the user to shut off disturbing noises very precisely. Also the extension for H2 tracer gas comes without competition and makes this device a essential tool for leak detectors.

    By F.A.S.T. GmbH based in Langenbrettach, GERMANY.

  • Beverage Analysis

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas/vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, & include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, & thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour & CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Premium

    Measurement solution for AD-211 VOC speciation in natural gas, syngas & gasification

    Composition of Natural Gas, Syngas via VOC Speciation

    The composition of fuel gas is important in order to determine calorific value and also to detect any unwanted contaminants in the gas. Online analysis is important in order to give real-time and direct action on issues.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Premium

    Applications and Air Pollutants Removed in the Petroleum/Petrochemical Industry

    Scrubbing of Hydrogen sulfide, mercaptans and other organosulfur compounds from sour gas and other sources. Proprietary regenerative scrubbing chemistries for hydrogen sulfide removal with sulfur production. By-product production systems for producing sodium hydrosulfide (Nash) from hydrogen sulfide. Sulfur dioxide scrubbing. Recover catalyst dust from FCC units. HCL storage tank vent scrubbing. Removal of HCL and particulate from thermal oxidizers burning chlorinated plastics. Marine drilling platforms sulfur dioxide thermal oxidizer emissions.  Asphalt plant scrubbers and hydrogen sulfide emissions from holding tanks. Pilot plant scrubber systems for hydrogen sulfide. Removal of halogenated and sulfur bearing gaseous compounds from high temperature thermal oxidizers and drilling platforms waste. Well drilling hydrochloric acid storage tanks.

    By Bionomic Industries Inc. based in Mahwah, NEW JERSEY (USA).

  • Premium

    Continuous emissions monitoring for palm oil plants

    Make more out of your mill. OPSIS tested and approved monitoring systems provide cost-effective and reliable on-line monitoring of several gas compounds, such as both high and low concentrations of methane, moisture, carbon dioxide and hydrogen sulphide, at several locations.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Analysis of H2S, Mercaptans and/or THT in natural gas with energyMEDOR

    Context & Challenges How to analyze H2S, mercaptans and/or THT for detecting the odor of the gas with the ability to have total organic sulfur calculation in a metering station?

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Gas Detection Solutions for Sour Gas

    The sour (H2S) content of hydrocarbon fields worldwide is increasing, and many natural gas fields have very high H2S – sometimes in excess of 50%. H2S is extremely dangerous because, although people can smell it at low levels (about 5 ppb) it does not smell much worse at the exposure limit value of 10 ppm or at potentially fatal levels in excess of 100 ppm. Therefore smell is an unreliable means of determining dangerous levels. Existing H2S point sensors are maintenance intensive, slow to respond and provide limited coverage. Most H2S sensors do not work reliably in hot or cold weather, or in humid marine environments.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Gas Analysis Systems for Catalysis, Thermal Analysis, Fermentation and Bio Fuels

    Hiden gas analysis systems provide for high sensitivity, wide dynamic range, real-time analysis of almost any gas and vapour. Hiden’s application specific gas analysis systems are tailored to meet the specific application requirements, and include a range of special sampling, vacuum pumping and vacuum accessories. Hot zone sampling accessories are included for evolved gas analysis from furnaces, and thermo gravimetric analysers, TGA, for example. Thermal analysis methods are vital for catalysis characterization. For thermal analysis including TPD/TPO/TPR, studies, Hiden gas analysis systems include enhanced pumping for hydrogen and special close coupled sampling to the TPD/TPO/TPR reactor for optimum thermal analysis response. In Biogas applications the simultaneous analysis of H2S, CO2, water vapour and CH4 in the PPM to 100% concentration range provides vital information for process development and process monitoring.

    By Hiden Analytical based in Warrington, UNITED KINGDOM.

  • Premium

    Total sulfur measurement for sulfur compounds in CO2 for food & beverage industry

    The BevAlert Model 8900 provides a total sulfur measurement for sulfur compounds in Carbon Dioxide. The measurement includes organic sulfides, Sulfur Dioxide, Carbonyl Sulfide, and Hydrogen Sulfide. The instrument is utilized by Specialty Gas Manufacturers and the Food and Beverage Industry to monitor sulfur compounds in CO2 used in carbonated beverages.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

  • Premium

    Portable and fixed gas analysers for sewage / waste water treatment AD

    AD of human waste has been common in many countries for years but increasing energy costs now drive efficiency. Sewage processors are large energy users and AD can offset and help manage this.

    By Geotech based in Leamington Spa, UNITED KINGDOM.

  • Premium

    Waste water treatment plants Screening area: stripping

    Context & Challenges Globally, the wastewater treatment is the first public health issue. Urban development leads to urbanization near waste water treatment plant and extension of sewerage network. These aspects induce to an augmentation of sulfur compounds (H2S, mercaptans and sulfides) which are very corrosive, odorant and toxic. To monitor this compounds online CHROMATOTEC® offers high meteorological solutions. To ensure the safety of operatives in the screening building/area of waste water treatment works an H2S analyzer has been installed in the main building to complement the protection provided by individual monitors. Chromatographic measurements show that other sulfurous compounds including Methylmercaptans are present in the air in addition to H2S.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Odour Monitoring

    Measurement of odours from pulp & paper, feedlots and natural sources is challenging and requires careful selection of instrumentation. Ecotech offers a complete monitoring solution designed for this application. Odours are one of the most common sources of air pollution complaints and may be due to a wide variety of sources from rotting vegetation, animal feedlots, pulp and paper manufacturing, sewerage treatment facilities etc. The measurement of odours is extremely difficult due to the variety of sources of odour and the often very low ppb concentrations that produce odour. However, some industries and applications have a known source of odour resulting from compounds such as mercaptans, hydrogen sulphide, ammonia, typically from industries such as pulp and paper manufacturing, fertiliser production or natural sources such as rotting vegetation. Ecotech is able to offer extremely sensitive instrumentation and systems that enables the low ppb monitoring of these species down to 1 ppb, fully integrated with our data evaluation and reporting software.

    By Ecotech Pty Ltd based in Knoxfield, AUSTRALIA.

  • Premium

    Water Treatment Solutions for Hydrogen Sulfide

    Sulfates and hydrogen sulfide are both common nuisance contaminants. Although neither is usually a significant health hazard, sulfates can have a temporary laxative effect on humans and young livestock. Sulfates also may clog plumbing and stain clothing. Hydrogen sulfide produces an offensive `rotten egg` odor and taste in the water, especially when the water is heated.

    By Adedge Water Technologies, LLC based in Buford, GEORGIA (US) (USA).

  • Premium

    Measurement of hydrogen sulfide & carbon disulfide in air for continous emission monitoring

    The Series 8900 Hydrogen Sulfide and Carbon Disulfide Analyzer provides direct measurement of H2S and CS2 in ambient air. This instrument is utilized for continuous emission monitoring. The Series 8900 H2S and CS2 Analyzer employs a Photoionization detector (PID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the H2S, CS2, and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. H2S and CS2 are separated from potentially interfering components on the analytical column and elute to the detector for analysis.

    By MOCON, Inc. - Baseline based in Lyons, COLORADO (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you