Only show results available in Virginia? Ok

Laser Gas Monitoring Applications

  • Premium

    Continuous emissions monitoring for palm oil plants

    Make more out of your mill. OPSIS tested and approved monitoring systems provide cost-effective and reliable on-line monitoring of several gas compounds, such as both high and low concentrations of methane, moisture, carbon dioxide and hydrogen sulphide, at several locations.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    O2 Monitoring in Air

    Oxygen (O2) is a colorless odorless gas, essential to all life on Earth but damaging in high concentrations. An O2 analyzer should thus be employed for safety management and air pollution prevention purposes. LasIR MP110 is perfect for continuous emission monitoring of O2. It is based on TDLAS technology and can be calibrated as an O2 analyzer, providing accurate and reliable measurements. It quickly responds to changes in compound concentration, thus providing continuous emission monitoring for the specified gas.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    NH3 Monitoring in Air

    NH3 (Ammonia) is a colorless gas with a distinctive pungent smell. Ammonia monitoring is essential in coal-fired power plants, where NH3 is used to reduce NOx emissions. The ammonia consumes all of the NOx, but its high concentration that is needed for these purposes also starts reacting with other things and in the process can clog up filters and cause premature failure of expensive SCR equipment and pre-heaters. Not to mention that these high levels create an irreparable damage to the environment.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    Industrial solutions for the carbon dioxide (co2) lasers

    Carbon Dioxide (CO2) lasers are high power lasers, usually used for cutting of ferrous and non-ferrous metals. High-performance gas flow control is a key requirement for achieving high cutting performance with CO2 lasers. Gas flow control plays an important role for mixing key gases at a number of locations with a CO2 laser: Beam Generation: The gas mixture used as the emitting medium usually consists of CO2, He and N2. Most laser manufacturers specify a minimum required purity for the beam generation gas mixture, which is typically > 99.99%. A highly-accurate gas mixing control is therefore necessary, either for production of pre-mixed gas cylinders, or for in-situ mixing within the laser unit.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Premium

    Laser gas detection for research

    Axetris laser gas detection OEM modules are used in a variety of research applications: Climate Change Research, Environmental Research.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Premium

    Emissions Monitoring for Mining / Emissions Monitoring for Smelting

    The Opsis monitoring solution for mining and smelting applications is based on either DOAS or laser diode technique. Opsis non-contact monitoring solutions are very well suited for applications in the Mining and Smelting Industries, as the flue gas conditions often involves high temperatures and high dust concentrations. The on-line, open-path systems are used for monitoring HF, sulphur dioxide, SO3 and HCl in potrooms, in fence-line applications and in continuous emissions monitoring.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Continuous emissions monitoring for steel plant

    The nature of steel manufacturing processes places severe limitations on the monitoring methods that can be used. Aggressive environments combined with high levels of particulates and gases make the choice very limited.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Hydrogen Fluoride (HF) Monitoring in Air

    Hydrogen Fluoride (HF) is a colorless gas that is used extensively in industrial applications. Fluoride monitoring is especially needed for aluminum plants that need to convert HF into fluorine for use in their processes. Any HF that escapes is a cost to the plant, so an HF analyzer is essential to keep track of and prevent the losses.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    HCl Monitoring in Air

    Hydrogen chloride (HCl) is a colorless, sometimes slightly yellow, gas. It is an undesired environmental component that may be damaging to workers and the surroundings. Exposure limits have thus been established by industries to make sure that the workers operate in a safe environment. HCl monitoring is especially required for incinerators, coal-fired power plants, aluminum recycling and cement plants. Unisearch offers a reliable and easy-to-use HCl analyzer – the TDLAS-based LasIR system. Studies have shown that TDLAS equipment provides data that is more accurate than conventional gas monitoring equipment. When calibrated for HCl monitoring, TDLAS is able to detect this gas among other gases present in the area and provide continuous updates with regards to the changes in its concentration.

    By Unisearch Associates Inc. based in Concord, ONTARIO (CANADA).

  • Premium

    Laser gas detection for medical sector

    Axetris laser gas detection OEM modules are used in a variety of medical applications: Breath Analysis.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Premium

    Laser gas detection for environmental compliance

    Axetris laser gas detection OEM modules are used in a variety of environmental applications: Biogas Detection, Continuous Emissions Monitoring CEM, Fugitive Emissions, Natural Gas Detection.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Premium

    Continuous emissions monitoring for mineral wool production

    Process control and emissions monitoring in a mineral wool plant is a challenge due to the presence of phenol and formaldehyde. To use an extractive system in this environment will demand a lot of maintenance. The OPSIS DOAS system is different and provides plants with an accurate analyser that will operate with a minimum of maintenance. The OPSIS DOAS system is based on a non-contact method using an optical measurement path that can operate across the duct.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Process monitoring solutions for NH3 truck engine monitoring

    A new EC regulation states that  diesel engines need to have active cleaning with urea injection in order to reduce NOx emissions. In order to control the urea dosage, a reliable measurement system is required. OPSIS LD500 laser diode gas analyser for monitoring ammonia (NH3), has been tested and approved by German TÜV, in accordance with the EURO VI standard.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Laser gas detection for process control

    Axetris laser gas detection OEM modules are used in a variety of process control applications: Agriculture, Industrial Process Control, Selective Catalytic Reduction.

    By Axetris Ag based in Kaegiswil, SWITZERLAND.

  • Environmental protection

    Laser Gas measurements Flue gas emissions, HCl, HF, CO, CO2, O2, NH3, NO, NO2

    By HANGZHOU ZETIAN TECHNOLOGY CO., LTD based in Hangzhou, CHINA.

  • Gas Detection Solutions for Carbon Fiber Manufacturing Industry

    The carbon fiber manufacturing industry requires a unique process control solution that conventional gas detection technology lacks. Boreal Laser’s line-of-sight laser based gas detection system is the perfect fit for measuring HF in various pan oven applications and stack emissions monitoring . Whether you are looking for gas detection solutions for safety, environmental or process control needs Boreal Laser has you covered.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Measurement solution for high NH3 monitoring from wastewater

    Protea was asked to supply a high level ammonia (NH3) measurement system for a waste water treatment plant. The reflux drums at the inlet to two ammonia stripping towers needed to be measured continuously. Protea designed a solution based around our Solus TDLAS analyser platform and a high level dilution system. The Solus analyser was configured for NH3 measurements in the range 0-500ppm. A dilution system incorporating special dilution probe and 19` control panel was installed before the analyser. This gave a dilution level of 600:1, enabling the NH3 analyser to measure in the range 0-30% Volume.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you