Laser Induced Fluorescence (LIF) Equipment For Monitoring And Testing In USA
-
Manufactured by Advanced Sensors Ltd. - part of PAC L.P.based in UNITED KINGDOM
The EX-100M is a side stream oil / particulate in water analyzer that combines video microscopy measurement for particle size analysis with the highly accurate Laser Induced Fluorescence oil content measurement technique. This allows measurement of Total Suspended Solids (TSS), oil droplet size and gas bubble size whilst still accurately measuring concentration of oil in water. In addition to the ...
-
Manufactured by Advanced Sensors Ltd. - part of PAC L.P.based in UNITED KINGDOM
The SA-100/1000 is a side stream Oil in Water analyzer suitable for non-hazardous areas; it uses fluorescence to provide continuous accurate measurements of oil concentrations in water. Reliable real-time data enables operators to take accurate discharge measurements and to improve efficiency of separation processes enabling cost reductions. The SA is ideally suited for marine, industrial and ...
-
Manufactured by McLane Research Laboratories, Inc.based in USA
The Imaging FlowCytobot (IFCB) is an in-situ automated submersible imaging flow cytometer that generates images of particles in-flow taken from the aquatic environment. The IFCB uses a combination of flow cytometric and video technology to capture high resolution images of suspended particles. Laser- induced fluorescence and light scattering from individual particles are measured and used to ...
-
Manufactured by Spectral Energiesbased in USA
Spectral Energies is pleased to offer their state-of-the-art Burst-Mode Laser Systems that are Master Oscillator Power Amplifier (MOPA) family of products, configurable for the simultaneous measurement of temperature, velocity, chemical species, and molecular-energy distributions at rates of 5 kHz to 1 MHz with point to planar resolution. The key to achieving high pulse energies at high ...
-
Manufactured by Advanced Sensors Ltd. - part of PAC L.P.based in UNITED KINGDOM
The EX-100P and the EX-100P2 are respectively a single and dual inline probe Oil in Water analyzers that use fluorescence to provide continuous accurate measurements of oil concentration in water. The additional probe on the EX-100P2 allows monitoring of two process points simultaneously with dual readings displayed on the analyzer. Reliable real-time data enables operators to take accurate ...
-
Manufactured by Photon Systems, Inc.based in USA
The Photon Systems’ single channel gated integrating detector (SCGID) is a plug & play gated boxcar integrator and averager that synchronizes detection current sources such as PMTs, photodiodes, optical beam induced current detectors or other current sources with the emission from a Photon Systems deep UV laser. It is plug and play with Photon Systems lasers and can be easily ...
-
Manufactured by Cascade Drillingbased in USA
Successful and cost effective LNAPL site management requires a CSM, including detailed knowledge of NAPL location and distribution. The Ultra-Violet Optical Screening Tool (UVOST) provides these data with unmatched speed, detail, and efficiency. Optimize your remedial design by finding, delineating and quantifying aromatic LNAPL with UVOST, a laser induced fluorescence direct sensing tool. ...
-
Manufactured by Advanced Sensors Ltd. - part of PAC L.P.based in UNITED KINGDOM
The EX-100/1000 is a side stream Oil in Water analyzer that uses fluorescence to provide continuous accurate measurements of oil concentrations in water. Reliable real-time data enables operators to take accurate discharge measurements and to improve efficiency of separation processes enabling cost reductions. In addition to the EX-100 features, the EX-1000 model offers spectral ...
-
Manufactured by AB Sciex Pte. Ltdbased in USA
Fast and practical high resolution separation and quantitation of charged and polar analytes. The P/ACE series is an automated, programmable capillary electrophoresis system designed to perform fast separations from complex samples. Separations occur in a capillary which is housed in an interchangeable cartridge with circulating liquid coolant for efficient temperature control. This finely ...
-
Manufactured by Advanced Sensors Ltd. - part of PAC L.P.based in UNITED KINGDOM
The SA-100P and the SA-100P2 are respectively single and dual inline probe Oil in Water analyzers suitable for non hazardous areas; they both use fluorescence to provide continuous accurate measurements of oil concentrations in water. The additional probe on the SA-100P2 allows monitoring of two process points simultaneously with dual readings displayed on the analyzer. Reliable real-time data ...
-
Manufactured by Spectral Energiesbased in USA
Spectral Energies, LLC has extensive experience in assembling fully operational, test-cell-worthy, high-speed planar laser-induced fluorescence (PLIF) and particle-image velocimetry (PIV) systems. The customer need only provide the test article, and SE can deliver the entire PLIF/PIV system, including lasers, cameras, breadboards, software, electronics, and optics. Initial measurements and ...
-
Manufactured by Advanced Sensors Ltd. - part of PAC L.P.based in UNITED KINGDOM
Fluorescence is a long established measurement technique and the most widespread technique for measuring oil in water. The measurement principle is based upon a physical characteristic of aromatic hydrocarbons. When exposed to UV or low blue light, the aromatic hydrocarbons absorb the energy from that light (excitation) and give off light of a different wavelength (emission). The amount of ...
-
Manufactured by National Oilwell Varco (NOV)based in USA
The WVM mixers consist of a simple wall additive injection point, a pre-distribution tab immediately downstream of the injection point and banks of trapezoidal shaped mixing elements. The number of banks of mixing elements varies depending on the mixture quality required for the process. The dimensions, angle of attack and spacing of the trapezoidal mixing elements varies between the WVM models ...
-
Manufactured by Dakota Technologies, Inc.based in USA
The Dye-enhanced laser induced fluorescence system (DyeLIF) tool is a new site characterization technology that facilitates rapid, cost-effective 3-dimensional (3-D) delineation of residual chlorinated solvent DNAPL in the subsurface. DyeLIF is based on combining time-resolved LIF technology with the injection of a fluorescent dye ahead of the window to render non-fluorescent NAPLs fluorescent ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you