Nox Monitoring Equipment For Monitoring And Testing In Latin America
-
PremiumManufactured by LNI Swissgasbased in SWITZERLAND
The Sonimix 2130 NOx converter tester has been designed to generate a stable NO2 concentration with a small reaction time. It is based on the sonic nozzles technology (ISO 6145-6 technology) and high stability pressure regulators. The NOx converter tester is often used together with a multi-steps gas divider also based on sonic nozzles and high precision pressure regulators. In order to validate ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Method 7C (Colorimetric) and 7D (Ion Chromatography) are used for the determination of nitrogen oxide emissions. A sample is passed through a series of specially built impinger that contains an alkaline potassium permanganate solution. The impingers are of standard height with a narrow bottle, which improves the collection efficiency. The sample rate is between 400 and 500 cubic centimeters per ...
-
PremiumManufactured by Real Tech Inc.based in CANADA
Real Tech’s robust submersible High Nitrite probe provides affordable real-time measurement of high concentrations of nitrite (NO2) in water or wastewater. The High Nitrite probe utilizes patent-pending technology to provide superior measurement performance across multiple wavelengths of light using UV LEDs. The probes rugged body is built to withstand harsh environments, with titanium or ...
-
PremiumManufactured by ENVEAbased in FRANCE
A complete “all in one compact” system, for multi-gas measurements, based on the field-proven MIR 9000 analyzer and on-board SEC sampling ...
-
PremiumManufactured by ENVEAbased in FRANCE
Perfect ammonia gas analyzer or multi-gas analyzer for the measurement in hot & wet flue-gas of: HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CO2, O2 and ...
-
PremiumManufactured by ENVEAbased in FRANCE
The In-Situ TDLS gas analyzer has been designed for meeting the requirements of a large range of CEMS and Process applications. LAS 5000XD uses Tunable Diode Laser Spectroscopy (TDLS) and comes in various models for measuring parameters such as NH3 + H2O, HF, CO + CO2, O2, HCl + H2O, ...
-
PremiumManufactured by Particle Measuring Systems (PMS)based in USA
The HPD III Aerosol Monitoring Accessory is compatible with non-toxic, non-flammable gases such as Clean Dry Air (CDA), Argon, Nitrogen and Carbon dioxide. Sampling gases at pressures greater than sea level, such as 25 – 100 psi, is challenging for particle counters. Connecting pressurized air or gas to a particle counter can defeat its flowmetering system and possibly damage the ...
-
PremiumManufactured by LNI Swissgasbased in SWITZERLAND
The Sonimix 4001 is a stand alone ozone primary transfer standard able to generate ozone together with dry or wet air (optional) allowing to calibrate the ozone monitors in several points. It generates an outflow of 3 Nl/min air containing 10 to 1000 ppb O3, with stability and reproducibility of the concentration better than 1% relative. The extended range model generates 10 ppb to 10 ppm at 3 ...
-
PremiumManufactured by LNI Swissgasbased in SWITZERLAND
The multipoint multigas calibrator SONIMIX 6000C1 is an instrument designed to calibrate manually or by remote control up to 5 gas monitors installed in an Air pollution monitoring station, such as SO2, HC or BTX, CO, NOx and O3. With the optional Ozone generator and GPT circuitry it is possible to verify the coherence of NO, NO2 and O3 analysers, and to determine the converter’s efficiency ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
OPSIS AQM systems measure multiple gases in real time over an open path. Using the DOAS (Differential Optical Absorption Spectroscopy) technique, the system is non-contact, with fast response. One system can be configured to monitor NO, NO2, SO2, O3, BTX, NH3, CO, CO2, HF, H2O, CH4, Hg, HCl, among other gaseous compounds. A basic system includes an analyser, an emitter/receiver set, and an ...
-
PremiumManufactured by Acme Engineering Prod. Ltd.based in CANADA
The ACME Wireless MultiSet series is a microprocessor-based multipoint multigas wireless detection and control system that can be used with the wireless CO and NO2 GasPost sensors. The communication between the Control Panel and the remote GasPost sensor/transmitters is accomplished through a 900 MHz or 2.4 GHz wireless network operating in a range of 1500-2000 ft., ...
-
PremiumManufactured by Environics, Inc.based in USA
The Environics® Series 7000 Zero Air Generator is a high purity air generator system that is capable of continuous delivery of up to 20 standard liters per minute (SLPM), 30 pounds per square inch (PSI) of dry, contaminant-free air. The Environics ZAG will produce high purity zero air from your dry compressed air source, eliminating the need for expensive, dangerous and bulky gas ...
-
PremiumManufactured by ENVEAbased in FRANCE
The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. The high quality sensors are renowned worldwide by our customers looking for the newest technologies in air quality monitoring. They offer precise and reliable measurement, and are calibrated using a reference-standard value. They come with a unique calibration certificate and don’t need any ...
-
PremiumManufactured by Gasmet Technologies - a Nederman companybased in FINLAND
Continuous Emission Monitoring System CEMS II e offers modular and TÜV and MCERTS certified (QAL1) solution for environmental compliance in industrial processes, such as powerplants, waste incineration, cement plants and beyond. The system adjusts to changes in regulations and future advances of emissions monitoring best practices with ...
-
PremiumManufactured by ENVEAbased in FRANCE
Heated Turnkey Gas Analysis System ideally suited for fast, continuous and simultaneous measurements of NH3 and NOx in DeNOx applications (SCR and SNCR). In DeNOx systems using urea injection with ammonia (NH3) as a reducing agent, the flow rate and control of NH3 must be continuously adjusted and controlled to prevent excess NH3 emissions (slip), to reduce environmental impact and cost of ...
-
PremiumManufactured by ENVEAbased in FRANCE
Dedicated to the measurement of regulated pollutants such as ozone (O3), carbon monoxide (CO), sulfur dioxide (SO2), nitrogen oxides (NO- NO2 and NOx), and particulates PM10 and PM2.5, the e-Series of analysers, has been designed with a special consideration to the environmental impacts of the product during its whole ...
-
PremiumManufactured by ENVEAbased in FRANCE
Gas monitor for fast, precise, direct and continuous measurement of NO2 concentrations in the range 0-1000 ppb. Visible (450 nm) absorption measurement using patented Cavity Attenuated Phase Shift (CAPS) technology. QAL1 certified by the TÜV, US-EPA approved. Fast and direct measurement of the sample – no chemical conversion required, no Toxic Gas ...
-
PremiumManufactured by LNI Swissgasbased in SWITZERLAND
The multigas calibrator with GPT, ozone and self re-generable zero air generator, Sonimix 3012/3022, is an instrument designed to calibrate manually or by remote control up to 6 monitors installed in an air pollution monitoring station, such as SO2, HC, BTX, CO, NOx and O3. ...
-
PremiumManufactured by ENVEAbased in FRANCE
Single reaction chamber version for the monitoring of NO or NOx, or dual chamber for NO, NOx and NO2 measurements. Exist in 2 different versions: TOPAZE 52M-S : NO or NOx monitoring. TOPAZE 52M-D : NO-NOx and NO2 simultaneous ...
-
PremiumManufactured by Real Tech Inc.based in CANADA
Real Tech’s Nitrite analyzer provides rapid real-time measurement of nitrite (NO2) in water. The Nitrite analyzer utilizes light at various wavelengths for measurement. Continuous nitrite monitoring can bring significant value to many applications especially for boilers, chillers and aquaculture. Parameter(s): ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you