Only show results available in Virginia? Ok

Open Path Gas Monitoring Applications

  • Premium

    Gas Detection and Analysis Equipment for Chemical and Petrochemical

    In a complex petrochemical facility there may be many thousands of potential leaks paths. Some may be leaking but most will not. Using an infrared Gas Detection camera allows the user to examine many potential leaks sources in a short time and from a distance. The EPA acknowledged gas imaging cameras, such as Opgal’s EyeCGas®, as an approved Leak Detection and Repair (LDAR) Method 21 alternate work practice (AWP).

    By Opgal Optronic Industries Ltd. based in Karmiel, ISRAEL.

  • Premium

    Open path ambient air quality monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring.

    By Cerex Monitoring Solutions, LLC. based in Atlanta, GEORGIA (US) (USA).

  • Premium

    Continuous emissions monitoring for aluminium smelters

    Process control and emissions monitoring in an aluminium smelter is a challenge due to the high concentrations of HF. To use an extractive system in this environment will demand a lot of maintenance.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Ambient air quality monitoring solutions for fence-line monitoring

    The OPSIS open-path monitoring system is an excellent tool for monitoring the air quality, fugitive emissions and gas leaks at industrial sites. By arranging monitoring paths strategically at locations outside the borderline of an industrial area, fugitive emissions and gas leaks will effectively be detected. By combining the measured gas data with meteorological parameters information such as where the pollution sources are located and the strength of the emissions can be calculated, using the EnviMan software.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Perimeter Ambient Air Monitoring

    Cerex Multi-Gas Open Path Analyzers are available in both FTIR and UVDOAS technologies to meet specific requirements for perimeter ambient air quality monitoring, leak detection, fugitive emissions monitoring and ambient air quality monitoring. Cerex multi-gas analyzers offer significant advantages over single gas analyzer arrays, electro-chemical sensor arrays and time integrated air sampling hardware

    By Cerex Monitoring Solutions, LLC. based in Atlanta, GEORGIA (US) (USA).

  • Premium

    Ambient air quality monitoring solutions for street-level monitoring

    To measure the air quality in a city is a challenge. A large number of gaseous components need to be measured with high accuracy. The monitoring site needs to be representative for the city and the system has to be easy to maintain and calibrate. The OPSIS open-path monitoring systems provide a flexible solution, giving the average concentration for an area. A single OPSIS system can measure all relevant gaseous components set by the authorities, such as NO, NO2, SO2, O3, BTX, NH3.

    By Opsis AB based in Furulund, SWEDEN.

  • Premium

    Urban air quality monitoring

    To measure air quality in the ambient air is a challenge. The monitoring site needs to be representative and not dependant on changes in local traffic. A large number of gaseous components need to be measured with high accuracy and high availability.

    By Opsis AB based in Furulund, SWEDEN.

  • Simultaneous Air Monitoring over Multiple Fixed Sample Paths

    Application: Simultaneous monitoring over multiple fixed sample paths either in-situ, extractive, or open path. Example: HF scrubber inlet, outlet, and stack monitoring in primary aluminum smelter.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Portable Leak Detection

    GasFinder2 can be used as a portable open path gas sensor to survey a large site relatively quickly. Areas of elevated gas concentration can be bracketed using shorter path lengths in order to locate leaking valves, flanges or fittings.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Single Gas Monitoring - Open Path Monitoring

    Application: measurements of single gas species through a fixed open air sample path. Example: HF leak detection in refinery HF Alkylation units.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

  • Integrated real-time gas analysis solution for electronic specialty gases industry

    The company’s entry into the electronic specialty gas market originated in 1994-95 as a consequence of the semiconductor industry’s demand for increasingly higher purity gases from the major gas producers. The issue was then and remains today to be primarily moisture impurity levels in the cleaning, etching, and treatment gases used in wafer production. In that earlier period when common wafer sizes were 6” and 12”, the semi industry required moisture concentrations to be 250 to 500 ppb or better; with each year after that the industry tightened its requirements such that today the moisture specifications are 1 to 5 ppb or better.

    By CIC Photonics, Inc. based in Albuquerque, NEW MEXICO (USA).

  • Emissions Monitoring for Cars

    GasFinderFC can be configured to monitor CO and CO2 simultaneously, and combined with the short open path probe, can be set up across roads to monitor instantaneous emissions of these gases from vehicles passing through the beam. Gross polluters can be identified and their number plates photographed.

    By Boreal Laser Inc. based in Edmonton, ALBERTA (CANADA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you