Optical Gas Monitoring Equipment For Monitoring And Testing Available In Marshall Islands
-
PremiumManufactured by Enviro Solutions Technology Co.,Ltdbased in CHINA
ESE-LASER-U500 based on the principle of tunable semiconductor laser absorption spectroscopy (TDLAS), laser gas analyzer scans and analyzes the gas absorption lines of specific wavelength, and realizes the gas concentration measurement by combining the digital lock-in amplifier and the advanced technology of long optical path. laser gas analyzer can realize high resolution, high precision, ...
-
PremiumManufactured by Hangzhou Chunlai Technology CO., Ltd.based in CHINA
Vehicle Exhaust Optical Bench is a gas analysis module based on Ultraviolet Differential Optical Absorption Spectroscopy(UV-DOAS), which is able to directly measure NO and NO2 in vehicle/steamship exhust and calculate NOx, without ...
-
Manufactured by Sterlitech Corporationbased in USA
Qualitative papers perform separation by trapping the particulates within the random matrix of cellulose fibers located in the depth of the media. These papers are used in methods requiring the determination and identification of particulates in both liquid and gas samples. The "Applications" tab compares detailed specification and application information for each filter grade. We also have ...
-
Manufactured by Sensor Electronics Corporationbased in USA
The SEC Millenium Infrared Hydrocarbon Gas Detector is a complete self contained optical hydrocarbon gas detector. The sensing and reference elements are self-compensating for optical integrity and other signal inhibitors. The SEC Millenium Hydrocarbon infrared gas detector can operate as a stand-alone 4-20mA gas detector or it can be coupled with an SEC 3100 Universal Transmitter or SEC 3100 ...
-
Manufactured by Sensia Solutionsbased in SPAIN
CAROLINE Y is the first cost-effective OGI of the market designed to detect methane (CHA) and sulphur dioxide (S02) leaks. It detects the 90% of the diffused gas emissions caused by leaks. The Caroline Series is compatible with RedLook App and RedLook Lite increasing the functionality and simplicity of the device. SENSIA's Sniffer and CAROLINE merge both methods, Smart LDAR and Method 21, in a ...
-
Manufactured by Oil & Gas Technologies (OG-TECH)based in FRANCE
A simple and user-friendly way to estimate in real-time, from a distance, the flow rate from the leaks found with our portable camera ...
-
Manufactured by EyeCGas - OGI by OPGALbased in ISRAEL
Quantification in leak rate (g/hr) and max concentration (e.g. ppm) values. Realtime & Offline On-location and remote quantitative measurement of leak rates for Methane and VOC's. Multiple Compound Quantification. Calibrated to accurately quantify most ...
-
Manufactured by IGM-DETECTOR Co. LTDbased in RUSSIA
The gas detector is designed for automatic, continuous measurement of the concentration of flammable hydrocarbon gases or carbon dioxide in the surrounding atmosphere. The calibration of explosive gas is produced with samples of methane, propane or hexane. The gas analyzer is designed for permanent installation. Main application Explosion-hazard areas and areas near external processing units, ...
-
Manufactured by EyeCGas - OGI by OPGALbased in ISRAEL
EyeCGas CO is a rugged OOOOa compliant handheld Optical Gas Imaging (OGI) camera for CO & CO2 gas leak detection. With this camera you can safely and remotely detect and locate carbon monoxide as well as other harmful gases emissions. It’s one of only a few OGI camera that is certified for ATEX zone 2 and UL class I Div II, hazardous ...
-
Manufactured by Sensia Solutionsbased in SPAIN
CAROLINE is the first cost-effective OGI of the market oriented to SF6, refrigerant gases, ammonia and other gas leaks detection. CAROLINE is compatible with RedLook App and RedLook Lite increasing the functionality and simplicity of the device. SENSlA's Sniffer and CAROLINE merge both methods, Smart LOAR and Method 21, in a smart and digital ...
-
Manufactured by Viper Drones LLCbased in USA
“Viper Vantage” will allow the operator to be environmentally compliant, reduce revenue loss, and maintain safety ...
-
Manufactured by FLIR Systems Inc.based in USA
The FLIR GFx320 represents ground-breaking technology for visualizing fugitive hydrocarbon leaks at natural gas well sites, off-shore platforms, liquid natural gas terminals, and more. Its certifications for use in hazardous locations allow surveyors to work confidently while maintaining safety. FLIR designed the GFx320 with the user in mind, offering ergonomic features such as the articulating ...
-
Manufactured by AMETEK MOCONbased in USA
The OpTech - O2 Model P is a simple yet effective tool for any laboratory with the need to measure oxygen inside a closed package or container. The OpTech gives the user the ability to measure the oxygen in a non-invasive manner through a transparent foil – making it perfect for shelf life determination of oxygen sensitive ...
-
Manufactured by Sensor Electronics Corporationbased in USA
The SEC Signature Process Gas Analyzer is a self-contained optical gas detector designed for non-intrusive continuous monitoring of process gases. These process gas analyzers operate in anaerobic atmospheres. The Signature Process infrared gas analyzer is unaffected by humidity and pressure. The infrared optical system is self-compensating (patented) for most aging, environmental, and ...
-
Manufactured by Semicore Equipment, Inc.based in USA
The CAPOSSM series PVD system boasts an industry first with a cost-effective “Open-Platform” architectural design. This means that the CAPOSSM offers many standard configuration options as well as the ability to incorporate custom features as unique as its user. Created for precise R&D and batch production by the design team at Semicore, a Silicon Valley based manufacturer of PVD, ...
-
Manufactured by Sensia Solutionsbased in SPAIN
Caroline fixed series integrate the latest technology in uncooled infrared detectors, offering consistent and error-free performance. It is the most complete system for constant monitoring of environments with risks of methane, SO2, VOC's, Natural Gas and/or hydrocarbons ...
-
Manufactured by CI Sensing, division of CI Systemsbased in ISRAEL
Continuous Emissions Monitoring Systems (CEMS) play a vital role in the reduction of greenhouse gas emissions. While Optical Gas Imaging (OGI) technology is widely used as an effective tool for leak detection and repair (LDAR) operations, in its handheld versions. Advancements in technology create an opportunity for continuous fixed installations as a new solution. ...
-
Manufactured by FLIR Systems Inc.based in USA
The QL320 by Providence Photonics is a quantitative optical gas imaging (QOGI) system that allows surveyors to measure the leak rates for methane and other hydrocarbons. This eliminates the need for secondary sampling with a toxic vapor analyzer or similar tool. Plus, the QL320 does not require close contact with the gas in order to measure emission rates, making it a safer solution for ...
-
Manufactured by FLIR Systems Inc.based in USA
The FLIR GF304 detects refrigerant gas leaks without interrupting or shutting down operations in food production, storage and retail; pharmaceutical; automotive; and air conditioning. Detecting refrigerant gas leaks early can save on costly replenishment and limit environmental impact. Refrigerant gases are highly toxic, environmentally harmful and heavily regulated. Leaks gone unchecked are ...
-
based in NETHERLANDS
In combination with the ATLAS software, TP Europe has acquired the newest technology of FLIR to immensely improve and optimize our Smart LDAR procedures. With the acquisition of the new FLIR QL320, the approach of our Smart LDAR procedures, along with our OGI FLIR camera, has significantly improved. Enabling the quantification of emissions where no other quantification instrument is required. ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you