Ozone Monitoring Articles

  • E-Z Trays an Integral Part of Levelland`s Groundwater Treatment - Case Study

    QED E-Z Tray® Air Strippers an Integral Part of Levelland's Groundwater Treatment System The refinery at the former Motor Fuels Corporation produced all grades of gasoline, tractor fuels, diesel, distillate products, and fuel oils. It closed in 1954 after 15 years of operation, and the refinery equipment was removed by 1958. The property has since been redeveloped, but the ...


    By QED Environmental Systems

  • Overview of Rotating Disc Electrode (RDE) Optical Emission Spectroscopy for In-Service Oil Analysis

    Introduction The basis of modern oil analysis is the use of optical emission spectroscopy (OES) to measure the ppm (parts per million) levels of wear metals, contaminants and additives in oil samples. Whatever else an oil lab may measure, a multi-elemental analysis is the core of in-service oil analysis. This paper gives an overview of Rotating Disc Electrode Elemental Spectroscopy and its ...


    By Spectro Scientific

  • Hardware Solutions to Monitor Gas and Thermal Energy

    Why Monitor Gas and Thermal Energy? Hang on, are you telling me you are an energy manager that’s only worried about electricity!? Let’s take a step back and realise that gas represents nearly 40% of the total energy consumed in the industrial and service sectors in Europe. That’s almost half, you guys! ...


    By DEXMA

  • Two Detector Solution to Analyzing Sulfur

    Sulfur compounds are reactive, corrosive to pipes, and destructive to catalysts in petroleum refineries. Sulfur emission are strictly regulated globally. When released into the atmosphere sulfur dioxide converts to sulfuric acid resulting in adverse effects on human health and the environment. Sulfur detection is found useful in many other industries; therefore, detection of sulfur compounds in ...


    By Restek Corporation

  • Direct Mass Flow or Volumetric: The Thermal Flow Meter Technology Advantage!

    In today’s world where everyone is watching the bottom line, you need high performance, cost-effective instrumentation—and capillary thermal mass flow meters and controllers have been proven to meet this criteria in a wide range of process applications. Thermal mass flow technology is an industry standard for mass flow control of gases because it measures flow directly, at the ...


    By Sierra Instruments, Inc.

  • Perfectly clean water - without the use of toxic chemicals - Case Study

    Bacteria-free surroundings breeds healthier and more productive cattle Danish Clean Water A/S is a manufacturer of ECA generators and has successfully marketed and deployed its generator for more than 5 years, sold to more than 20 countries through local partnerships and has thereby gained significant market power. The ECA generator can be used in various industries and production sites, ...

  • Ozone-depleting substances 2015

    Aggregated data reported by companies on the import, export, production, destruction, and feedstock and process agent use of ozone-depleting substances in the European Union Executive Summary Background Chemicals known to harm the ozone layer have been successfully substituted in most parts of the world since 1989, when the Montreal Protocol on Substances ...

  • Degradation of Reactive Yellow X-RG by O3/Fenton system: response surface approach, reaction mechanism, and degradation pathway

    O3/Fenton for the treatment of effluent containing Reactive Yellow X-RG is investigated. The response surface methodology is applied to study the main and interactive effects of the parameters. With the initial dye concentration being controlled at 300 mg L−1, the optimized conditions for wastewater treatment are 3.68, 29.19 and 18.49 mg min−1 for initial pH, mole ratio of ...


    By IWA Publishing

  • Disinfection By-Products (DBP) Precursor Monitoring

    Chlorine has long been used as a primary disinfection method for many water and wastewater treatment applications. However, there is growing concern about the harmful DBP’s produced by the use of chlorine. DBP’s, such as triahalomethanes (THMs), can occur when the natural organic matter (NOM) that is present in the water is combined with chlorine. More specifically, the portion of ...


    By Real Tech Inc.

  • AQMesh: a new option for flexible air quality monitoring

    AQMesh has an impressive collection of global users and performance results measuring ambient air quality in applications ranging from traffic planning and urban hotspots to industrial fence line monitoring, building ventilation management, or environmental lobbying. This pole-mounted unit comes with an independent power supply and communications, so offering the possibility of measuring air ...


    By AQMesh

  • The effects of elevated ozone and CO2 on growth and defense of native, exotic and invader trees

    Abstract Aims Elevated ozone and CO2 can differentially affect the performance of plant species. Variation among native, exotic, and invader species in their growth and defense responses to CO2 and ozone may shape CO2 and ozone effects on invasions, perhaps in part also due to variation between native and invasive populations of invaders. Methods ...


    By Jansen Poultry Equipment

  • BM Respirometry

    BM respirometery is a state of the art technology in where the traditional and most advanced respirometry techniques are gathered in one exclusive design developed by SURCIS Company. BM Respirometry makes use of a single reaction vessel that in certain mode replicates the actions that occur at a treatment plant under the conditions we set for the test. The BM system, under a powerful ...


    By SURCIS, S.L.

  • Trade SIA on the Environmental Goods Agreement OZONATOR - Case Study

    An innovative technology has been developed in Canada for the processing of medical and bio-hazardous waste using ozone as the sterilizing agent. Ozone is generated and is produced from ambient air and any residual ozone is converted back to oxygen, resulting in zero emissions. Waste is sterilized at room temperature without heat, steam, chemicals, flames, exhaust, odours with nothing to drain or ...


    By OZONATOR Industries Limited

  • Modeling Tip: Using Ozone File Editor Tools in BREEZE AERMOD

    To model 1-hour and annual concentrations of NO2 for the National Ambient Air Quality Standard (NAAQS), the U.S. EPA has approved a three-tiered approach as detailed in Section 5.2.4 of EPA’s Guideline on Air Quality Models, Appendix W to 40 CFR Part 511 (Appendix W). This approach, as shown below, is recommended to estimate the ambient concentrations of ...

  • Olive mill effluent depuration by ozonation and Fenton processes enhanced by iron wastes

    The aim of the present work was to compare the potential of iron industry wastes to enhance ozone and hydrogen peroxide action on the degradation of olive mill wastewaters (OMWs). The results attained show a higher efficiency for ozonation using a lower catalyst load. Nevertheless, Fenton's process led to a larger amount of chemical oxidation demand (COD) removed per mole of oxidant applied. ...


    By IWA Publishing

  • Ozone Based AOP process for refractory COD reduction in industrial waster water

    Introduction In recent years improvements  in ozone based advanced oxidation technology efficiencies have lowered capital and operating expenses, improving the viability of the use of ozone as the main oxidant. An investigation into alternatives for refractory COD removal which is economically attractive and do not produce sludge lead to an evaluation of ...


    By ESCO International

  • Comparison of O3 + GAC, O3 + H2O2 + GAC, and GAC unit operation on natural organic matter and taste and odor causing compounds removal using a pilot plant study

    Removal of natural organic matter (NOM) and taste and odor problems in drinking water are a sensitive issue in municipal water treatment plants. This study investigated the effectiveness of ozone (O3) + granular activated carbon (GAC), O3 + hydroperoxide (H2O2) + GAC, and GAC processes using a pilot scale plant to remove NOM and geosmin (50–1,000 ng/L), and ...


    By IWA Publishing

  • Monitoring pollution in remote regions of Africa case study

    Customer: The South African Weather Service (SAWS) Ecotech’s Distributor: SI Analytics (Pty) Ltd Application: Ambient Air Monitoring in Karoo and Waterberg regions of South Africa Background: Carbon Monoxide and Sulfur Dioxide are among the major pollutants found in cities around the ...


    By Ecotech Pty Ltd

  • Want to change the future? Pay attention to the past.

    From Mandela to MLK to McKibben, history offers lessons aplenty for climate activists We all know the plotline: Single-minded, passionate activists attempt to take on immense money and power, hidebound ideology and bureaucratic paralysis to turn the tide on the most important issue ever. We could be talking about climate change. But we could also be talking about the abolition of ...


    By Ensia

  • Decreased UV absorbance as an indicator of micropollutant removal efficiency in wastewater treated with ozone

    Ozone transforms various organic compounds that absorb light within the UV and visible spectra. UV absorbance can therefore be used to detect the transformation of chemicals during ozonation. In wastewater, decolourisation can be observed after ozonation. This study investigates the correlation of the UV absorbance difference between the ozonation inlet and outlet and the removal efficiency of ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you