Particulate Sampling Equipment
-
Manufactured by Westech Scientific Instruments (Westech)based in UNITED KINGDOM
The M9096 In-Stack Manual Method Particulate Sampler for ISO9096, EN13284-1, US EPA Method ...
-
Manufactured by Comde-Derenda GmbHbased in GERMANY
The PNS T-DM combines a low / medium volume sampler (LVS or MVS) and a filter changer in a stainless steel cabinet. It collects fine particulate matter on sampling filters according to EN 12341:2014 (PM10 and PM2.5). For this purpose, a vacuum pump draws in ambient air, and the system fractionates the airborne particles in a sampling ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The High Volume PM 2.5 ambient air sampling inlet & retrofit kits are designed to provide existing owners of HI-Q Series High Volume PM-10 sampling systems with the option of retrofitting them into High Volume PM-2.5 Samplers, instead of needing to procure a new, complete, PM-2.5 high volume air sampler. An adapter is placed into the ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
HI-Q Environmental Products Company’s AK-Series adjustable Annular Kinetic Impactor Heads are designed for collecting alpha, beta, & gamma-emitting contaminants, plutonium fission, Radon decay products and size specific dust particles. By adjusting the stopping distance (nozzle to impactor plate distance) and varying the particle velocities an operator can collect size specific dust ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
HI-Q Environmental Products Company’s High Volume PM-10 Size Selective Inlet samples suspended particulate in the air at a flow rate of 40 CFM through its omnidirectional head. The air is then accelerated through multiple internal nozzles toward a greased collection plate. Due to their larger momentum, particles greater than 10 ...
-
Manufactured by Kinesis Inc - Cole-Parmer Instrument Companybased in UNITED KINGDOM
of a standard syringe filter (either 0.22 or 0.45µm porosity and 4, 13, 25 or 30mm diameter), some samples that are particulate laden will block the selected syringe filter, even when using the largest ...
-
Manufactured by JCT Analysentechnik GmbHbased in AUSTRIA
Applications: For extractive gas analysis. For emission and process monitoring. For removal of dust and contamination from sample gas. For protection of the analysers. For integration in gas analysis ...
-
Manufactured by Soniya Scientific Equipment Solutions Pvt. Ltd.based in INDIA
SSES-APD-001 suck ambient air using low maintenance brushless and noiseless blower through corrosion free aluminum modular pipe and pass thorough a sharp cutoff cyclone which divides the particulate matters in two fractions: one below 10 microns (10µ). The Respirable dust (below 10 microns) directly get deposited on the glass micro ...
-
Manufactured by Polltech Instruments Pvt. Ltd.based in INDIA
Ambient Fine Dust Sampler (ADS) now comes with a USB based data transfer interface and a revised PC based application program for data presentation and ...
-
Manufactured by American Ecotech LLCbased in USA
The MicroVol 1100 low volume air sampler provides a flexible sampling platform for PM10, PM25 or TSP particulates and basic meteorological parameters. The MicroVol 1100 is suitable for both indoor and outdoor applications. The unit is microprocessor controlled and uses a mass flow sensor in conjunction with ambient temperature and pressure ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Apex Instruments stocks a variety of fiber thimbles for in-stack particulate sampling. The thimbles are seamless, high purity filters, and available in two different fiber types: borosilicate glass and quartz. Borosilicate glass fiber thimbles are acid-washed to reduce the trace metal content to an absolute minimum. The quartz fiber ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Glass Fiber Filters are most the commonly used filters for particulate sampling. All of the glass fiber filters are binder free and exhibit at least 99.95% efficiency for 0.3 μm dioctyl phthalate (DOP) smoke particles. 934AH is available. Not recommended for metals ...
-
PremiumManufactured by ENVEAbased in FRANCE
Designed to automatically sample particulates on filters using a TSP, PM10, PM2.5 or PM1 inlet. PM162M is a sequential automatic sampling device for particulate matter in the ambient air. The particles are sampled at constant flow rate (1 m3/h or 2.3 m3/h) and collected on filters for gravimetric weighing and ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
These High Volume Air Samplers are housed in a clear-anodized aluminum outdoor shelter. The Brushless, two or three stage centrifugal fan blower can be used for particulate sampling with either a 4” diameter or 8” x 10” filter paper holder. The blower motor has a variable speed control feature which allows the operator to ...
-
PremiumManufactured by Access Sensor Technologies LLCbased in USA
A two liter per minute inlet allows you to push your PM2.5 limits of detection lower with a higher flow ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Apex Instruments stocks a variety of fiber thimbles for in-stack particulate sampling. The thimbles are seamless, high purity filters, and available in two different fiber types: borosilicate glass and quartz. Borosilicate glass fiber thimbles are acid-washed to reduce the trace metal content to an absolute minimum. The quartz fiber ...
-
PremiumManufactured by Tekran Instruments Corporationbased in CANADA
Tekran and VE Technology have partnered together to improve the quality of Natural Gas sampling and analysis. Proper sample collection requires precision equipment to assure mercury is quantitatively transported between the source pipeline and the sample collection device. The Tekran 2642 Natural Gas Sampler paired with a Tekran 2600-NG ...
-
PremiumManufactured by Access Sensor Technologies LLCbased in USA
PM2.5 is monitored worldwide for ambient and personal exposure to harmful ...
-
PremiumManufactured by ENVEAbased in FRANCE
US EPA PS11 capable ProScatter™ particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Apex Instruments stocks a variety of fiber thimbles for in-stack particulate sampling. The thimbles are seamless, high purity filters, and available in two different fiber types: borosilicate glass and quartz. Borosilicate glass fiber thimbles are acid-washed to reduce the trace metal content to an absolute minimum. The quartz fiber ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you