Infrared Radiometer (Radiometer) Equipment
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-1H1 is an un-amplified analog sensor with a voltage output. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. The sensor has a response time of ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-121 is an un-amplified analog sensor with a voltage output. The sensor has a 18° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-111 is an un-amplified analog sensor with a voltage output. The sensor has a 22° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The MI-2H0 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SIF-111 is a fast response model infrared radiometer with a 0.2 second response time. The analog sensor is un-amplified and has a voltage output. The sensor has a 22° half-angle field of view. Typical applications include plant canopy temperature measurement for use in plant water status estimation, phenotyping, phenomics, road ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The MI-220 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The sensor has a 18° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The MI-210 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The sensor has a 22° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-131 is an un-amplified analog sensor with a voltage output. The sensor has a 14° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SIF-1H1 is a fast response model infrared radiometer with a 0.2 second response time. The analog sensor is un-amplified and has a voltage output. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SIF-121 is a fast response model infrared radiometer with a 0.2 second response time. The analog sensor is un-amplified and has a voltage output. The sensor has a 18° half-angle field of view. Typical applications include plant canopy temperature measurement for use in plant water status estimation, phenotyping, phenomics, road ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The MI-230 has a hand-held meter, attached via cable, that displays and stores sensor measurements. The sensor has a 14° half-angle field of view and a response time of 0.6 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-421 has an SDI-12 digital output. The sensor has an 18° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-411 has an SDI-12 digital output. The sensor has a 22° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-4H1 has an SDI-12 digital output. The unique geometry of the sensor gives a wide 32° half-angle field of view in the horizontal direction with a 13° half-angle field of view in the vertical direction. This enables the user to mount the sensor at shallower angles without seeing above the horizon while maximizing the area measured. The sensor has a response time of 0.1 seconds. Typical ...
-
Manufactured by Apogee Instruments, Inc.based in USA
The SI-431 has an SDI-12 digital output. The sensor has a 14° half-angle field of view and a response time of 0.1 seconds. Typical applications include plant canopy temperature measurement for use in plant water status estimation, road surface temperature measurement of determination of icing conditions, and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Advanced Energy’s Mikron M360 blackbody calibration source combines portability, a wide temperature range, high emissivity, and remarkable resolution. Weighs only 17.8 kg (39.3 lb). High accuracy ±0.2% of reading ±1°C. Manufactured and tested to meet rigid quality control standards. Optional aperture ...
-
Manufactured by CI Semibased in ISRAEL
The NTM-W is an infrared radiometer, optimized for temperature measurement of opaque targets starting from below room temperature. The high sensitivity and broad dynamic range allow very low temperatures to be accurately measured. Application dependent algorithms allow for subtraction of interfering background radiation. Flexible design for ...
-
Manufactured by Radiometer Physics GmbH (RPG)based in GERMANY
RPG's profiling radiometers are mainly used to derive vertical profiles of atmospheric temperature and humidity (RPG-HATPRO). The infrared radiometer extension allows to cloud base height and ice cloud detection.The radiometer series covers high-resolution temperature profiling of the boundary layer and low-humidity applications. ...
-
by e-GEOSbased in ITALY
ALOS-2 is the follow-on JAXA L-SAR satellite mission of ALOS (Daichi) approved by the Japanese government in late 2008. The overall objective is to provide data continuity to be used for cartography, regional observation, disaster monitoring, and environmental monitoring.The post-ALOS program of JAXA has the goal to continue the ALOS (nicknamed Daichi) data utilization - consisting of ALOS-2 (SAR ...
-
Manufactured by Ball Corporationbased in USA
CALIPSO (Cloud-Aerosol LIDAR and Infrared Pathfinder Satellite Observations) is a mission dedicated to studying how clouds and aerosols impact the Earth’s climate. Scientists are using data from CALIPSO to construct 3D models of the atmosphere that improve our ability to predict future climate change. CALIPSO's LIDAR can also be ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you