Scintillation Counting Equipment For Monitoring And Testing Available In Montana
-
PremiumManufactured by Bertin Technologiesbased in FRANCE
Specially designed for border security, nuclear power plant control, along with major event safety, the ultra-sensitive SaphyGATE GN is a Gamma-Neutron portal monitor able to detect Special Nuclear Materials in a non-invasive ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
VF’s line of Hand/Foot Contamination Monitors is used to measure the alpha, beta, and gamma contamination on hands and feet. Different types and thicknesses of smart scintillation detectors are used to determine the type of radiation measured and the efficiency of the detectors. Using dual phosphors, the discrimination of alpha from beta activity is ...
-
PremiumManufactured by Bertin Technologiesbased in FRANCE
RanidPort Mobile is advanced spectrometric radiological portal monitor designed for mobile use in cars, boats, helicopters or airplanes. RanidPort Mobile is only truly portable spectroscopy radiation portal monitor available at this size and it is easy to transport in its own rugged detection and transportation case. RanidPort’s high volume Nal(Tl) scintillation detector ensures the rapid ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The PAM series of portable meters are compact,lightweight, hand-held instruments used to measure surface contamination from alpha, beta, and gamma activity. Low maintenance scintillation detectors are used to measure the contamination. Dual phosphor detectors with electronics are available for discrimination of alpha from beta ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The FCM-11 Contamination Monitor is used to measure the surface contamination of workers, their clothing, and equipment. Scintillation detectors are used to measure the alpha, beta, and gamma surface activity. The SFP series of smart frisking probes are used to detect the surface contamination. The SFP series probe has a standard active area of 15.5 in squared (100 cm squared) and can be provided ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The SIM series of small items contamination monitors are devices for monitoring small objects that may be contaminated by gamma radionuclides. The measured objects are inserted into a shielded measuring chamber. Standard chamber volumes available are 17 L, 27 L and 101 Ll. Two to six smart scintillation detectors are used as ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The FloorScan series of monitors are used to measure the alpha, beta, and gamma contamination on floors. Low maintenance smart scintillation detectors are used to measure the contamination. Dual phosphor detectors with electronics are available for discrimination of alpha from beta activity. Versions with one or two 81.4-in2 (525 cm2) active area detectors are ...
-
PremiumManufactured by Bertin Technologiesbased in FRANCE
SaphyGATE G is an easy-to-use Radiation Portal Monitor optimized for truck, train and cargo radiation control. It is based on large-surface, high-volume plastic detectors providing the highest ...
-
PremiumManufactured by F&J Specialty Products, Inc.based in USA
The MRB500H3E Tritium Bubbler is the state-of-the-art discriminating tritium collection instrument. Sample gas enters the instrument and flows through two (2) standard scintillation counter ready vials filled with ethylene glycol, which retain the HTO component. The sample gas, now less the tritiated water vapor, flows through a heated palladium sponge catalyst bed, which oxidizes the sample gas. ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The PAM-100 and PAM-170 series meters are portable hand-held user-friendly and ergonomically designed instruments intended for measuring surface contamination of alpha, beta and gamma emitting radionuclides (depending on the detectors used). Smart gasless scintillation detectors with an active area of 100 cm^2 or 170 cm^2 are used. A dual phosphor detectors with two channel electronics for alpha ...
-
PremiumManufactured by F&J Specialty Products, Inc.based in USA
Glass fiber filters are perhaps the most highly engineered fibrous filtration media available for research and industrial applications. Glass microfibers, the starting raw material, are entirely man-made. Since the ultimate retention characteristics of the filter paper are determined by the microfibre diameter, rigid manufacturing controls are imposed to produce consistent, controlled diameter ...
-
PremiumManufactured by F&J Specialty Products, Inc.based in USA
Sample gas enters the instrument and flows through two (2) standard scintillation counter ready vials filled with ethylene glycol, which retain the HTO component. The sample gas, now less the tritiated water vapor, flows through a heated palladium sponge catalyst bed, which oxidizes the sample gas. The oxidized sample gas flows through two (2) more vials with ethylene glycol that retain the ...
-
Manufactured by D-tect Systemsbased in USA
When just finding radiation isn’t enough, the Rad-ID quickly identifies radioactive isotopes with the touch of a button. An advanced handheld radiation identifier, the Rad-ID has 91 distinct radioisotopes in its customizable library, including medical isotopes, industrial isotopes, and special nuclear ...
-
Manufactured by CapeScint a subsidiary of CapeSym, Inc.based in USA
Dual-mode neutron-gamma natural (7%) 6Li enriched nEL-51×51 Scintillation Detector Assembly includes Ø50.8×50.8 mm (Ø2”x2”) high-performance ElpasoLight crystal coupled to Hamamatsu R6231 PMT hermetically packed in an Aluminum housing with 0.5mm thick walls and integrated magnetic shield and temperature sensor ...
-
Manufactured by D-tect Systemsbased in USA
The Rad-DXG is a ruggedized, industrial grade gateway monitor that can be utilized to detect radioactive material. The Rad-DXG utilizes large area plastic scintillators totaling up to 1440 cubic inches to detect the movement of gamma emitting isotopes passing through doorways, entrance gates or other similar openings. The instrument is durable and easy to operate with minimal training. ...
-
Manufactured by Campbell/Harris Security Equipment Company (CSECO)based in USA
The K910G will functionally be the same as our previous Buster with new safety features included. The radioactive source is now at 25% smaller than any other density meter and all lead components have been removed, making the K910G by far the safest and most environmentally friendly model on the market. The Buster K910G will also now come with a two year free ...
-
Manufactured by Stratum Reservoirbased in USA
Heavy shielded Spectral Gamma Logger for optimal signal detection. Instrument is designed for improved core gamma measurements. Measures the natural radioactivity present in well cores. All sedimentary rocks contain natural radioactivity). Detects total gross gamma (API units) and elemental contribution of Potassium (%), Uranium (ppm) and Thorium ...
-
Distributed by Qal-Tek Associatesbased in USA
The Falcon-1EXLCD operates on an automatic communication network that allows users to monitor a full network of Falcons as long as they are in range of another single Falcon system! The Falcon units will automatically form an intelligent, self-healing mesh network, allowing them to be constantly connected to each other as well as to the user network. This area monitor houses a sensitive ...
-
Manufactured by Arrow-Tech, Inc.based in USA
The CT007-F is a compact alpha, beta, gamma detector. This makes it suitable for identifying radioactive contamination. Unlike pancake Geiger-Mueller tube based instruments, it is light, compact, and ...
-
Manufactured by Brandelbased in USA
Automatic Deposit/Dispensing Systems accept filter paper sheets from your Harvester, punch the paper into discs, deposit discs into scintillation vials or tubes, and dispense cocktail to all vials at once. Elapsed time? About two minutes. Manual Deposit Systems accept filter paper sheets from your Harvester, punch the paper into discs and deposit discs into scintillation vials or tubes without ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you