Stack Testing Equipment For Monitoring And Testing Available In North Carolina
-
ShowcaseManufactured by EMC Hycal Limitedbased in UNITED KINGDOM
Probe longevity: 100 measurements typical, 20 hours continuous immersion. Response time: 5 minutes to stable result, response time less than 2 seconds. Footprint: approx. 1/2 volume, approx. 1/2 weight. Operating expense: 3x lower running cost, reduced degassing ...
-
ShowcaseManufactured by ECO Physics AGbased in SWITZERLAND
The nCLD 82 S is the next generation in measuring NOx. Unique in speed and precision, the nCLD 82 S is modular designed and expandable to additional nitrogen based parameters. Its new and intuitive user interface “GUI“ also individually displays and connects to other instruments’ ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments Standard Method 5 Heated Probe features a 1-inch diameter sheath constructed from corrosion-resistant stainless steel, modular 3/8-inch pitot tip, 1/4-inch stainless steel quick connects, type-K thermocouples for stack and probe temperature, probe heater, orsat line, and a small parts package. Standard lengths are 3 feet to 16 feet. Probes are ordered according to nominal ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
PM 10/PM2.5 Set combines the in-stack measurement of particulate matter (PM) equal to or less than an aerodynamic diameter of nominally 10 (PM10) and 2.5 (PM2.5 ) microns from stationary sources. The sampling train and operation are identical to Method 201A except that the PM2.5 cyclone is inserted between the PM10 cyclone and the 47-mm filter. The PM10 cyclone collects particulate matter ...
-
PremiumManufactured by ECO Physics AGbased in SWITZERLAND
The nCLD 844 M analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 M is modular designed and capable of simultaneously measuring NO, NOx and NO2. The analyzers expandable capabilities allow assessment of hot and humid gas sources without additional cooler. It features a dual inlet option for evaluation of two ...
-
PremiumManufactured by ECO Physics AGbased in SWITZERLAND
The nCLD 844 Mh analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 Mh is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface “GUI“ also individually displays and connects to ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
PM10 is used for Method 201A testing and is designed for in-stack measurement of particulate matter equal to or less than 10 microns. The shank has a 5/8-inch outer diameter for easy adaptation to an in-stack 47-mm filter assembly or probe. The PM10 cyclone kit includes cyclone assembly, PM10 nozzle set, 47-mm filter assembly, and a carrying case. Kits are available in stainless steel or alloy ...
-
PremiumManufactured by Fluid Components International LLC. (FCI)based in USA
The MT100 Series is an insertion type, multipoint thermal flow meter specifically designed for large diameter pipes, such as stacks, industrial chimneys, and flues, and large rectangular ducts, such as air feed intakes and HVAC. These large pipe/duct applications are difficult for ordinary flow meters because of distorted flow profiles and lack of straight-run that can lead to inaccurate and ...
-
PremiumManufactured by ENVEAbased in FRANCE
The MIR 9000P belongs to the new generation of ENVEA gas monitors, showcasing eco-design, IoT and on board intelligence. It measures simultaneously 8 gases – NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O – and uses the non-dispersive infrared method (NDIR-GFC) with gas filter correlation. O2 is measured by a built-in SRM paramagnetic sensor. The analyzer has been designed to meet ...
-
PremiumManufactured by AMETEK Land Instruments International Ltdbased in UNITED KINGDOM
A high-specification opacity and dust monitor meeting global compliance standards for monitoring combustion processes. 4500 MkIII is the most accurate and reliable continuous opacity monitor available, combining AMETEK Land’s ground-breaking innovation and simple design for precise, problem-free operation. Unmatched, class-leading accuracy ensures compliance limits for dust emissions and ...
-
PremiumManufactured by ECO Physics AGbased in SWITZERLAND
The nCLD 822 Mh analyzer is the next generation in high precision two-channel nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 Mh is modular designed and capable of simultaneously measuring NO, NOx and NO2 from hot and humid gas sources without additional cooler. It features a dual inlet option for assessing two different sources at once. The new and intuitive graphical ...
-
PremiumManufactured by Siemens Industry, Inc. - Process Analyticsbased in USA
Based on the Clean Air Act as well as local regulations, increasingly stringent environmental regulations require the overall reduction of Sulfur emissions. Consequently, it is necessary to monitor and control specific sulfur constituents and total sulfur content in products that are combusted and emitted. Siemens on-line MAXUM Process Gas Chromatographs and Gas Analyzers are utilized for Total ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments Method 17 Isokinetic Sampling System, featuring the XC-53 metering console, is ideal for collecting and determining in-stack particulate emissions from a wide variety of sources. Particulate emissions are commonly sampled from coal-fired power plants, cement kilns, asphalt plants, incinerators and industrial sources. Emissions data can be used for determining compliance ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
System 400FL combines the benefits of hot wet extractive and in situ. The gas is moved at high speed in a bypass line. No filter or probe is used and the measurement takes place in a non-contact measurement ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The HFID Model 603 is a competitively priced, digitally controlled self extracting, heated total hydrocarbon analyzer for high accuracy, sensitivity and long term stability. It can be used in a 19' rack or as a table top ...
-
PremiumManufactured by IMR Environmental Equipment, Inc.based in USA
The IM 1120 Flue Gas Analyser with its new, innovative HMI concept is controlled via the IM-Smart app and ensures simple operation, handling and evaluation for the user. Free IM-Smart app for remote operation of the IM 1120 with a tablet or smartphone. Various measurement modes with report generating function are available: Flue gas analysis - Differential Temperature - Oxygen Gap - CO Ambient - ...
-
PremiumManufactured by Optical Scientific Inc. (OSi)based in USA
The OFS-2000F was designed specifically for Flares stack sand reports flow velocities from 0.03 - 170 m/sec with a ± 2% accuracy. OSi's patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates an accurate average flow reading. It is the only flow sensor that gives a true non-contacting cross-stack flow measurement of ...
-
PremiumManufactured by ENVEAbased in FRANCE
Ideal for mid-high to high concentrations, also for sampling locations in hazardous areas ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Apex Instruments has a large selection of button-hook nozzles in multiple materials. Determining the size needed for isokinetic sampling depends on the stack gas velocity. Determining the material depends on the stack temperature and the sampling method. We provide technical support and can help with configuration. ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
Our model VE7 heated FID is being manufactured since 1974 and is the first heated THC analyzer ever built with a permanent back purge sample filter. It is still the most liked heated FID throughout the stack testing community due to its legendary ruggedness, forgivingness and long standing accuracy and sensitivity. The VE7 belongs to the very first total hydrocarbon analyzers being officially ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you