Filter sand, supplied in bags and pallet packages: The filter sand, consisting of 99.5% SiO2, is extremely low in trace metals and aromatic hydrocarbons. This makes our filter sand the best sand available for monitoring well ...
-
PremiumManufactured by Genesis Water Technologies, Inc.based in USA
Our Coconut Shell Activated carbon media is available in granular form in the following mesh sizes, 8×30 mesh, 12×40 mesh, and 20×50 mesh for liquid water purification. Our coconut shell activated carbon media is used in both commercial/industrial process water, to remove trace hydrocarbons, volatile organic compounds, low weight organics such as BTEX, color, and pesticides. It ...
-
Manufactured by Servomex - a Spectris Companybased in USA
High performance FID measurements of total Hydrocarbons (THC) and quality control in pure oxygen, nitrogen, argon, helium, air and carbon dioxide. The FID is a high specification Flame Ionization Detector (FID) based analyzer that provides a robust and high accuracy solution to trace Total Hydrocarbon (THC) measurements, ensuring gas stream inflammibility levels are closely ...
-
Manufactured by JCT Analysentechnik GmbHbased in AUSTRIA
Applications: For ultra high purity hydrogen production with electrolytic selective palladium membrane technology. Fuel gas for flame ionisation detectors (FID), nitrogen phosphor detectors (NPD) and flame photometric detectors. For carrier gas applications like gas chromatography (GC) and gas chromatography with mass spectrometry coupling ...
-
Manufactured by Restek Corporationbased in USA
Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal for process-type applications where recalibration must be minimized. High loadability reduces peak tailing and improves separations. Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) ...
-
Manufactured by Restek Corporationbased in USA
Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene. Stable response factors make this column ideal for process-type applications where recalibration must be minimized. High loadability reduces peak tailing and improves separations. Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) ...
-
Manufactured by Focused Photonics Inc. (FPI)based in CHINA
The EXPEC-3200 portable methane and non-methane hydrocarbon analyzer adopt heat tracing technology to transfer the heat up to 180 degrees and FID technology, effectively avoiding the loss of high boiling points and high concentration samples. EXPEC-3200 can accurately measure compositions of all hydrocarbons, methane, non-methane, and other characteristic emission factors of exhaust gas from ...
-
Manufactured by Zhengzhou Dayang Oil Chemical Equipment Co.,Ltd.based in CHINA
There are always a certain amount of free fatty acids in vegetable oils, depending on the quality of the oil.The immaturity of seeds and the high damage of seeds are the causes of the high acid value of the oil, especially under the condition of high moisture, which is very unfavorable to the oil preservation, which will increase the free acid content, reduce the quality of the oil, and worsen ...
-
Manufactured by Hypro Engineers Pvt. Ltd.based in INDIA
We have already started collecting CO2 and recycling it back to the process of Hops Extraction. Hypro successfully supplied a CO2 Recovery Plant of 700 kg/hr capacity to YCH through ICC Group, United States. The technology – conceptualization by Hypro MD Mr. Ravi Varma makes the whole CO2 System one of a kind. Hypro Engineers indigenously worked on the design, development, and ...
-
Manufactured by Sarvesh Analytics Pvt. Ltd.based in INDIA
The Online trace Nitrogen in Argon / Helium Analyser for High Purity Argon / Helium is based on unique Plasma Emission Detector. It can detect N2 upto 0.1 ppb. The Trace N2 measurement can be combined with Trace Oxygen, Moisture and Hydrocarbon. Optionally the system can come with an internal Zero calibration eliminating the need for Zero ...
-
Manufactured by Amazon Filters Ltd.based in UNITED KINGDOM
The removal of trace hydrocarbons from partially processed water prior to discharge can be a challenging and costly exercise. In response to the need for better technology for this application, Amazon Filters has introduced the SupaSorb range of cartridges. SupaSorb cartridges are so effective that they can absorb up to 300% of their dry weight in oil/hydrocarbon. These modules provide economical ...
-
Manufactured by MYCELX Technologies Corporationbased in USA
The core component of the MYCELX system is the MYCELX Advanced Polisher. The polisher removes traces of hydrocarbon contamination, even highly emulsified and soluble oils, down to critically low levels. The MYCELX Advanced Polisher can easily achieve oil and hydrocarbon removal down to 1 ppm or below. The MYCELX Advanced Polisher uses patented MYCELX polymer filter cartridges that remove fine ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M W600 Heated Total Hydrocarbon Analyzer is a very compact wall or panel mount heated FID analyzer to continuously measure the total concentration of hydrocarbons within a gaseous sample. This can be ambient air, exhaust gases from a combustion process e.g. stack emissions, from any type of an industrial vent, from an internal combustion engine, or from any other emission containing ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
Our transportable model 3-200 fully heated FID is successfully used throughout international markets for over 30 years. Also among other portable gas FIDs, the 3-200 It is the first ever built transportable fully heated FID using our proprietary back purge sample filter. It is widely distributed throughout the industry and the stack testing community and is much liked for its ruggedness, high ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M Heated Total Hydrocarbon Analyzer Model 3-600 FID is another low cost alternative to continuously measure the total concentration of hydrocarbons within a gaseous sample. This can be ambient air, exhaust gases from a combustion process e.g. stack emissions, from any type of an industrial vent, from an internal combustion engine, or from any other emission containing hydrocarbons. The ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
Our HFID Model H100 is a compact heated FID analyzer for high purity hydrogen applications. The H100 measures low trace total hydrocarbon concentration in Hydrogen. For fastest response and highest accuracy except the pressure regulator all components in contact with sample are housed in a 190 deg Celsius heated oven.. The Model H100 is ideally suited for the detection of very low traces of ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The HFID Model 603 is a competitively priced, digitally controlled self extracting, heated total hydrocarbon analyzer for high accuracy, sensitivity and long term stability. It can be used in a 19' rack or as a table top ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M 3-800 Portable Heated Total Hydrocarbon Analyzer is a heavy duty FID analyzer to continuously measure the total concentration of hydrocarbons within a gaseous sample. This can be ambient air, exhaust gases from a combustion process e.g. stack emissions, from any type of an industrial vent, from an internal combustion engine, or from any other emission containing hydrocarbons. The 3-800 ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M Heated Total Hydrocarbon Analyzer Model 3-700 FID is designed to be installed directly upstream of a FTIR analyzer (e.g. Gasmet) to continuously measure the total concentration of hydrocarbons within a gaseous sample. All controls which allow to calibrate the FTIR or FID individually are built in. Sources can be ambient air, exhaust gases from a combustion process e.g. stack emissions, ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M Heated Total Hydrocarbon Analyzer Model 3-500 FID is our lowest cost alternative to continuously measure the total concentration of hydrocarbons within a gaseous sample. This can be ambient air, exhaust gases from a combustion process e.g. stack emissions, from any type of an industrial vent, from an internal combustion engine, or from any other emission containing hydrocarbons. The ...