Only show results available in Connecticut? Ok

VOC Analysis Applications

  • Premium

    Analysis of VOC compounds in water by Purge & Trap or dynamic headspace

    Context & Challenges Volatile organic compounds (VOC) can be dissolved in water. Sometimes water is polluted and to study contamination of VOC in finished drinking water, VOC must be measured. Chromatotec® Solutions Chromatotec® has developed a specific system for the measurement of VOC in water: a Purge & Trap system, the airmoPURGE. The analyzer is coupled with a degasing system allowing the extraction of dissolved gases. The complete system is based on: - 502.2 method from US EPA –...

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Analysis of VOCs emissions from a car painting line

    During car manufacturing, Volatile Organic Compounds (VOCs) associated with the paints are emitted to the atmosphere. These are carcinogen, toxic and lead to tropospheric ozone formation. Therefore, VOC emissions must be reduced. With this aim, Chromatotec® airmoVOC C6-C12 (GC-FID analyzer) has been used to monitor VOC emissions from a car painting line. Indeed, it can measure concentrations ranging from very low (ppt) to high (ppm) level, so it is suitable for emission measurements. When coupled to MS...

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Gas analyzers for plant protection and process optimization

    Problem: Analyze total chlorines as well as organic compounds with a quick time response. Motive:Protects and authorizes the incinerator functioning : VOC limits the ability to incinerate Chlorine and fluorides limits the ability to incinerate to protect the incinerator Analytical Solution: VOC analyzed from the FID GC The total Halogenated compounds Installation of a reactor to convert the chlorines and the fluorides into HCl and HF Halogenated compounds analysis with our instrument Hx analyzer Technical...

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    Gas analyzers for measuring VOCs in water

    AirmOzone Purge & Trap ref. A52022-502. The complete unit with analysers for continuous monitoring of 60 VOC including BTEX with US EPA 502-2 method.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    vigi e-nose analyzers for for tracking VOCs.

    The vigi e-nose is an analyzer able to track VOCs, Sulfur compounds and other molecules such as ammonia for example. It allows to provide a rich global fingerprint to correlate with human sensory evaluation as dynamic olfactometry as example. It is possible to train the vigi e-nose with human sensory samples to study correlation with ASTM 679-E04 or EN 13725. As electronic nose, it provides chemical and olfactive fingerprint. The main differences are that vigi e-nose offers with single instrument : Speciation...

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    BTEX and VOC gas analyzers for ambient air monitoring

    This market is driven by law and legislations made in Europe and/or USA (US EPA). It deals with ambient air monitoring : analysis / calibration / automatic zero air in continuous 7 days a week. Ambient air monitoring: in France this service is controlled by associations that calculate the ATMO index. CHROMATOTEC instruments such as the BTX ,the Sulfur and the VOC analyzers can be a good complement of their analyzers such as O3, CO2, DUST… in the analysis of ambient air.

    By Chromatotec Group based in Val de Virvée, FRANCE.

  • Premium

    PTR-MS systems for biological research

    Real-time measurement of plant defense and leaf wounding reactions. Measurement of VOCs in dynamic biological systems with low detection limit and without sample preparation.

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Premium

    PTR-MS systems for medical applications

    PTR-MS are powerful tools for non-invasive, real-time breath gas analysis with many applications, such as screening for disease markers, study of pharmacokinetics or metabolic processes.

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Premium

    PTR-TOFMS systems for Flux Measurement of BVOCs

    The ultra-fast analysis capabilities of IONICON PTR-TOF instruments are essential for eddy covariance flux measurements, allowing to study deposition and emission rates of biogenic volatile organic compounds (BVOCs).

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Premium

    PTR-MS systems for food & flavor science

    Aroma real-time quantification with PTR-MS. Rapid screening for complex aroma systems. Rich chemical fingerprints due to soft ionization. Real-time sampling: high throughput. Ideal for chemometric data-mining methods.

    By Ionicon Analytik Ges.m.b.H. based in Innsbruck, AUSTRIA.

  • Measurement solution for measuring total VOC via FTIR

    Current Total VOC MeasurementsThe most common, and current standard, method for measuring Total Volatile Organic Compounds (VOC) is the use of a Flamed Ionisation Detector (FID). This gives a representative value of the total carbon content of a gas stream, as the FID cannot tell which specific organic compounds are present.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Measurement solution for complex, real-time VOC measurement with atmosFIR FTIR gas analyser platform

    IntroductionVolatile organic compounds (VOCs) are a group of organic compounds which have a low vapour pressure at room temperature, meaning that they will readily evaporate into the surrounding air. The term VOC refers to many different classes of organic compounds such as alkanes, alkenes, alcohols, aldehydes, aromatics and many more.

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Measurement solution for total VOC via FTIR

    Total Volatile Organic Compounds (VOCs) is a common measurement required from industrial emissions. Commonly, a single measurement value is obtained through the use of a Flame Ionisation Detection (FID) analyser. The pyrolysis of the gas stream in a FID analyser allows it to make a measurement of the carbon content of the gas stream. FID analyser cannot indicate the relative abundances of different organic species in a gas stream and often have widely different responses for different gases. However, they are...

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • Measurement solution for VOC emissions monitoring

    Protea has used our VOC gas analysers in many projects requiring the monitoring of complex mixes of VOCs. In the chemical and pharmaceutical industry, VOC abatement plants such as scrubbers and carbon-bed systems are typical installations where the use of Protea analysers and our VOC analysis expertise have proved valuable to plant operators. They prove a very powerful and flexible tool in both process gas measurements and VOC emissions monitoring. In the laboratory, Protea can deliver instruments with all the...

    By Protea Limited based in Middlewich, UNITED KINGDOM.

  • VOC / HAPs reporting

    The Wercs has developed an online reporting module which enables manufacturers to completely eliminate the manual system that is in place for VOC/HAPs reporting. This new module automatically gathers VOC/HAPs data from SDSs and cross-references it with the order history. Your customers can now go to a secured website, enter the name of the product and get a complete VOC/HAPs emission analysis for annual reporting requirements.

    By UL - The WERCS based in Latham, NEW YORK (USA).

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you