3" HDPE VOC tips 9 units per box. The technique used to fill a VOA vial is at least as important a source of variance in VOC analysis as is well purging protocol or sampler design. The more the sample stream is agitated or exposed to the air during the transfer of sample from the bailer to the vial, the lower the concentration detected in the vial will be. The greatest loss of VOC's occurs when ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
A GC/PID for automatic monitoring of BTEX in air, water and soils. This instrument uses a port valve with a single absorbent trap, and a 30 meter metallic 0.28 mm ID column. Minimum detection level as low as 10 ppt for application Benzene or 1,3-Butadiene in ambient air. Miniaturization, sensitivity, mobility and flexibility are its main features. Everything from the sample port up to the data ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
A GC/FID instrument for BTEX monitoring in air, water and soil. The airmoVOC BTX is a gas chromatograph for the analysis and monitoring of trace amounts of benzene, toluene, ethylbenzene (m/p/o) xylene by FID ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
A GC PID for automatic monitoring of compounds, in air, water or soils: This instrument uses a port valve with a loop, and a metallic 0.53 mm ID column. It has a minimum detection level of ppb. Miniaturization, sensitivity, mobility and flexibility are its main features. Everything from the sample port up to the data storage is integrated in a 19' rack 4U. Isothermal oven in standard (programmed ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
A GC/FID instrument for Volatile and Semi Volatile Hydrocarbons measurement in ambient air. The airmoVOC C6C20+ is used to monitor VOCs up to the semi volatile hydrocarbons in industrial site, tropical forest and on site under decontamination. With detection limit as low as 1 ppt for Benzene or Naphthalene the system can measure gaseous PAHs in ambient air in continue up to Fluorene and linear ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
Hydroxychrom is a gas generator providing high purity (grade: 99.9995%) of hydrogen used as carrier gas or fuel gas for autoGC FID (for VOCs) and FPD (for sulfur compounds). Generator of high purity hydrogen used a carrier gas for airmoVOC and chromaFID analysers as well as for the FID flame. Hydroxychrom is a high purity hydrogen generator and an important tool for the incoming H2 of FID, FPD ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
airmo HCHO is designed for the measurement of formaldehyde in air or pure gases. The airmo HCHO is an autoGC using FID detector dedicated to Formaldehyde monitoring at low concentration. This instrument uses a valve with a single sorbent trap, a metallic column and a ...
-
PremiumManufactured by Voss Technologies, Inc.based in USA
1.5" HDPE VOC tips 24 units per box. The technique used to fill a VOA vial is at least as important a source of variance in VOC analysis as is well purging protocol or sampler design. The more the sample stream is agitated or exposed to the air during the transfer of sample from the bailer to the vial, the lower the concentration detected in the vial will be. The greatest loss of VOC's occurs ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
Our system airmOzone C2-C12 allows you to analyze the VOC thanks to: the calibration system with a bottle or permeation tube, a H2 generator, in-built LCD computer with our own operation software VISTACHROM, airmopump sampling, Peltier effect : for cooling, Airmopure : air generator. Applications in the atmosphere pollution, in the petrochemical fence line and clean air ...
-
PremiumManufactured by Voss Technologies, Inc.based in USA
The technique used to fill a VOA vial is at least as important a source of variance in VOC analysis as is well purging protocol or sampler design. The more the sample stream is agitated or exposed to the air during the transfer of sample from the bailer to the vial, the lower the concentration detected in the vial will be. The greatest loss of VOC's occurs when the sample is simply poured into ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
A standalone Process Auto GC-FID for WATER monitoring. Integrated solution for qualification of impurities in process in liquid matrices. Turn-Key Solution – Wall-Mounted box with integrated calibration and ...
-
PremiumManufactured by Voss Technologies, Inc.based in USA
The technique used to fill a VOA vial is at least as important a source of variance in VOC analysis as is well purging protocol or sampler design. The more the sample stream is agitated or exposed to the air during the transfer of sample from the bailer to the vial, the lower the concentration detected in the vial will be. The greatest loss of VOC's occurs when the sample is simply poured into ...
-
PremiumManufactured by Hangzhou Chunlai Technology CO., Ltd.based in CHINA
TGA-100P portable VOC gas analyzer is based on FID and PID detection technology, which can achieve ultra-high sensitivity and rapid detection and analysis of VOC gases in ambient air. The analyzer adopts intrinsically safe and explosion-proof design, consisting of two parts: main unit and sampling rod, equipped with explosion-proof hand manipulator, with fast system response, small volume and ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
An all in one solution including dual combined autoGCs FID: airmoVOC C2C6 and airmoVOC C6C12. This solution is provided worldwide for ozone precursors monitoring in ambient air. The airmOzone utilizes the airmoVOC C2-C6 and an airmoVOC C6-C12 with FID to monitor ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
A GC/PID for automatic monitoring of BTEX in air, water and soils This instrument uses a port valve with a single absorbent trap, and a 30 meter metallic 0.28 mm ID column. Minimum detection level as low as 10 ppt for application Benzene or 1,3-Butadiene in ambient air. Miniaturization, sensitivity, mobility and flexibility are its main features. Everything from the sample port up to the data ...
-
PremiumManufactured by Synspec BVbased in NETHERLANDS
For the accurate and reliable monitoring of VOC concentrations, every analytical instrument needs to be calibrated periodically. Synspec supplies various multi-point calibration stations for the validation of your ...
-
PremiumManufactured by Voss Technologies, Inc.based in USA
The technique used to fill a VOA vial is at least as important a source of variance in VOC analysis as is well purging protocol or sampler design. The more the sample stream is agitated or exposed to the air during the transfer of sample from the bailer to the vial, the lower the concentration detected in the vial will be. The greatest loss of VOC's occurs when the sample is simply poured into ...
-
PremiumManufactured by Oizom Instruments Pvt. Ltd.based in INDIA
The AQBot VOC is a robust VOC Gas Monitor that can measure Volatile Organic Compounds in the air. This VOC gas detector uses photoionization detection (PID) technology to measure total volatile organic compounds in the air. This sensor module is enclosed in the IP65 rugged composite enclosure to protect from harsh ...
-
PremiumManufactured by Voss Technologies, Inc.based in USA
The technique used to fill a VOA vial is at least as important a source of variance in VOC analysis as is well purging protocol or sampler design. The more the sample stream is agitated or exposed to the air during the transfer of sample from the bailer to the vial, the lower the concentration detected in the vial will be. The greatest loss of VOC's occurs when the sample is simply poured into ...
-
PremiumManufactured by Chromatotec Groupbased in FRANCE
CH4 and Non Methane Total Hydro Carbon (NMTHC) Monitoring and analysis of Methane and Non-Methane Hydrocarbons by flame ionisation detection (ppm level analysis). The CHROMATHC is an automated isothermal industrial gas chromatograph dedicated to the analysis of volatile organic compounds in air (indoor, outdoor, combustion), industrial hygiene, pure gas like N2/CO2/O2. ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you