Only show results available in Virginia? Ok

Water Level Monitoring Applications

  • Liquid Level Contents Gauges -

    Gauges for the Ship Building & Offshore Industries We have the following Liquid Level Contents Gauges For Ship Building & Offshore use, the G35 and G31 models meet the requirements for SOLAS for use with flammable liquids, they are type approved by Lloyds, DNV and Rina amongst others. G35 Seemag- Magnetic Gauge: Approved for use on flamable Liquids G31 Seeflex - Reflex Gauge : Approved for use on flamable Liquids G21 Marine - Tubular gauge G20 Admiralty - Tubular gauge G22 Quickmount -Tubular gauge G34 Quickflex - Reflex Gauge - We have a new brochure detailing our range of products for the marine & shipbuilding industry. View/Download this brochure: http://www.seetru.com/datasheets/gauges/Seetru_Marine_Gauge_Brochure.pdf

    By Seetru Limited based in Bristol, UNITED KINGDOM.

  • Data analysis and visualization tools for groundwater modeling

    Groundwater and Solute Transport modeling is a sub discipline of environmental sciences with unique needs. Modeling has long utilized 3D simulations, but the ability to visualize the results has lagged far behind the simulation technology. EVS-PRO and MVS have long offered professional level presentation tools worthy of the current state-of-the-art in modeling, and EnterVol now opens that door to GIS professionals around the world. Visualization of groundwater and solute transport modeling results can be performed from third party modeling systems such as USGS MODFLOW, MT3D, GMS©, Groundwater Vistas and Visual MODFLOW© using C Tech’s tools to convert these modeling outputs into EFF format. In conjunction with Lawrence Livermore National Laboratory and IT Group, C Tech performed the visualization and animation of the output from a Groundwater Vistas MODFLOW and MT3D99 simulation of a large industrial complex in the central valley area of California.  This site exhibits highly channelized flow which is evidenced by the flow paths. Note that flow in the lower aquifer crosses underneath the upper channels at about 30 degrees!

    By C Tech Development Corporation based in Henderson, NEVADA (USA).

  • Water measurement systems & sensors for status & condition-based monitoring

    We offer a variety of telemetry based solutions to monitor and control assets:

    By Isodaq Technology - Hydro-Logic Group based in Bromyard, UNITED KINGDOM.

  • Data analysis and visualization tools for groundwater and solute transport

    Groundwater and Solute Transport modeling is a sub discipline of environmental sciences with unique needs. Modeling has long utilized 3D simulations, but the ability to visualize and animate the results has lagged far behind the simulation technology. EVS-PRO, MVS, and EnterVol offer professional level presentation tools worthy of the current state-of-the-art in modeling. Visualization of groundwater and solute transport modeling results can be performed with all versions of C Tech’s software except for EVS for ArcView. EVS-Pro, MVS, and EnterVol are particularly well suited for animation and visualization of earth science modeling results from third party modeling systems such as USGS MODFLOW, MT3D, GMS©, Groundwater Vistas© and Visual MODFLOW©. Both combine animation capabilities with a powerful suite of visualization tools in a fully customizable environment.

    By C Tech Development Corporation based in Henderson, NEVADA (USA).

  • Premium

    Measurement and control systems for the Indicating the level - mechanically

    Depending on the regulations, a steam boiler must be equipped with one or more direct and/ or indirect level gauges. With direct level gauges, the liquid level can be seen directly through a glass or mica window. The use of a transparent level gauge with background illumination gives operating staff a clear separation between the water and steam zones even when viewed at a relatively long distance. Bicolour level gauges (black and white or green and red) are very suitable for camera transmission to the measuring station because of their special design and the intense LED illumination. With indirect level gauges, the water level is transmitted by a magnetic system to a display panel on the outside of a pipe.

    By IGEMA GmbH based in Münster, GERMANY.

  • Premium

    Pump station level controllers for pump staton call outs

    Town operators were plagued by high level alarm call outs at two new sewage lift stations. Read how they used Greyline`s hybrid ultrasonic level controllers with dual sensor capability to put an end to level alarms.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Premium

    Differential level transmitter for VFD pump control & flow measurement

    An Ontario municipality deploys Portable flowmeters to solve flow rate discrepancies between sewage pump station effluent and lagoon influent flowmeters. Faced with suspension of construction permits due to flow rate uncertainty, the Township of North Glengarry called on Greyline Instruments to help troubleshoot two permanently installed flow meters.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Premium

    Biofouling control in cooling basins

    Prevent biofilm formation and lower bacterial counts, and chemical consumption.

    By LG Sonic based in Zoetermeer, NETHERLANDS.

  • Premium

    Flow Metering in Channel with Dry Weather Flume

    Application: Segmented rectangular channel, 3 m width. Part filled. Rectangular channel made of concrete. Channel with dry weather flume and side space.

    By NIVUS GmbH based in Eppingen, GERMANY.

  • Premium

    Measurement and control systems for the Limiting the level - electronically

    A distinction is made between low water (LW) and high water (HW) limiters. Whereas LW limiters are in principle required for the safe operation of a plant in accordance with European regulations, HW limitation (overfill protection) is required only in accordance with TRD 604 for 72-hour operation.

    By IGEMA GmbH based in Münster, GERMANY.

  • Industrial solutions for water monitoring

    Water monitoring involves many different activitites, from ensuring the quality of surface or underground water, both for human beings and animal life, to the monitoring of a country’s water infrastructure. Wireless sensor networks are becoming increasingly popular in this area and ADVANTICSYS has already explored its use for many novel applications.

    By Advantic Sistemas y Servicios S.L based in Alcobendas, SPAIN.

  • Premium

    Level indicating transmitter for swimming pool level control

    A Surge Tank is used at the Okatokes Rec Centre Swimming Pool to regulate pool level. By monitoring level in a surge tank the non-contacting Greyline LIT25 Level Indicating Transmitter controls makeup water flow through a solenoid valve.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Premium

    Water Level Monitoring

    By Stevens Water Monitoring Systems, Inc. based in Portland, OREGON (USA).

  • Water measurement systems & sensors for measuring water level & depth

    The recommended type of measurement system or water level logger system will depend on several site-specific factors such as :-

    By Isodaq Technology - Hydro-Logic Group based in Bromyard, UNITED KINGDOM.

  • Dams and Dikes Structural Health Monitoring Systems

    The control of a dam requires a wide range of important information coming from the sensors, which are of vital importance for the life of a dam. Engineers in charge can take specific and sudden decisions for a correct control of a dam`s reservoir, body and foundations. However, monitoring is not only carried out by sensors, but it also involves direct or remote visual inspection as well as topographical measuring.

    By Roctest - part of Nova Metrix LLC based in Saint-Lambert, QUEBEC (CANADA).

  • Agricultural, Storm and Highway Runoff

    The ability to collect useful data about sediment transport and other pollutants closely coupled to SSC (such as nutrients, e-coli, phosphates and nitrates) is dependent on the timing and frequency of manual grab samples during run-off events. Most sediment and pollutant is transported during a small number of storm events which are infrequent and unpredictable. When they do occur, trained personnel or the proper equipment may not be available to collect grab samples. An automated pump sampler can eliminate the need to sample manually, but for the expense of a rechargeable power system, the autosampler, and possibly a datalogger and a typical turbidity probe, you’re no better off. With an automated pump sampler driven by the DTS-12 digital turbidity sensor and controlled by the Axiom H2 datalogger, you obtain a better understanding of the water’s quality, while taking a minimum number of samples, reducing site visits and saving lab analysis costs.

    By FTS based in Victoria, BRITISH COLUMBIA (CANADA).

  • River Level Monitoring -

    SUMMARY Fielded water level measurement stations, based on GaugerGSM sensor, report real time stream levels and flow. Stations are located across a stream-rich region of the upper Galilee feeding the Jordan river in the northern part of Israel. The region is a popular tourist destination due to its biblical origins, rich flora and fauna. Field data is available over the Internet to authorized engineers, site supervisors and Government officials. remote monitoring station - close up THE NEED The water basin in the Upper Galilee maintains a delicate balance between recharges, net precipitation, domestic and irrigation consumption, and water tourism (canoeing). Local and state officials are tasked to study the tradeoffs, manage risks and take actions to keep the balance. Monitoring stations are essential for data collection. remote monitoring station - overall

    By Solid Applied Technologies Ltd. (SolidAT) based in Ashkelon, ISRAEL.

  • Premium

    Ultrasonic Level Monitoring for Water Bottling Plant Level Control

    Culligan Water installs Greyline SLT32 Level Monitors to control tank levels in their bottling plant in Calgary, Alberta. With non-contacting ultrasonic sensors the SLT32`s control fill and discharge valves in five tanks containing spring water, reverse osmosis water and distilled water.

    By Greyline Instruments Inc. based in Long Sault, ONTARIO (CANADA).

  • Premium

    Flow Measurement In Cooling Water Tap for chemical industry

    Application: Closed rectangular channel, 3.8 x 3.5 m (h x w). Part filled. Walls and bottom made of concrete.

    By NIVUS GmbH based in Eppingen, GERMANY.

  • Premium

    Algae control in ponds

    A safe method for larger ponds to control suspended and filamentous algae without harming the ecological balance in the pond.

    By LG Sonic based in Zoetermeer, NETHERLANDS.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you