ASTM E1151 - 93(2011) Standard Practice for Ion Chromatography Terms and Relationships

0

Source: ASTM International

This practice deals primarily with identifying the terms and relationships of those techniques that use ion exchange chromatography to separate mixtures and a conductivity detector to detect the separated components. However, most of the terms should also apply to ion chromatographic techniques that employ other separation and detection mechanisms. The apparatus to be used in the chromatography shall consist of syringe pumps, reciprocating pumps, pneumatic pumps, septum injectors, valve injectors, precolumns, concentrator columns, guard columns, separating columns, suppressor columns, conductivity suppressors, membrane suppressors, micromembrane suppressor, bulk property detectors, and solute property detectors. Chemical reagents to be used in the chemical analysis shall be of four kinds: mobile phase, stationary phase, solid support, and column packing materials. The stationary phase has two types which are the liquid phase and interactive solid phase material. Totally porous packing and pellicular packing are the two types of column packing materials.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1 This practice deals primarily with identifying the terms and relationships of those techniques that use ion exchange chromatography to separate mixtures and a conductivity detector to detect the separated components. However, most of the terms should also apply to ion chromatographic techniques that employ other separation and detection mechanisms.

1.2 Because ion chromatography is a liquid chromatographic technique, this practice uses, whenever possible the terms and relationships identified in Practice E682.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)

ASTM Standards
E682 Practice for Liquid Chromatography Terms and Relationships

Index Terms

; Baseline; Bonded phase; Cation exchange capacity; Column length; Conductance and conductivity (electrical); Ion chromatography (IC); Ion exchange materials/applications; Liquids; Peak/peak base; Retention parameters/symbols/units; Stationary phase; Temperature tests; Terminology--chromatography

ICS Code

DOI: 10.1520/E1151-93R11

ASTM International is a member of CrossRef.