ASTM E1514 - 98(2011) standard specification for structural standing seam steel roof panel systems

0

Source: ASTM International

This specification covers the design, construction, and weatherability of structural standing seam steel roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers. Panel material shall be a hot dip metallic coated product in accordance with one of the following commonly used materials: aluminum-, aluminum-zinc alloy-, zinc-, or zinc-5% aluminum alloy metallic-coated sheet steel. The roof system shall be designed for specified design loads and thermal effects without causing seam separation, permanent panel buckling, or weather-tightness loss. Deflection and serviceability shall be accounted for in the panel system for structural integrity. Static and uplift index tests shall be performed to determine the roof's load capacity. Standing seam roof panel systems shall be installed in accordance with the system design requirements.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1 This specification covers the design, construction, and weatherability of structural standing seam steel roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers.

Note 1—These systems are used on both low-slope and steep-slope roof applications. They also are used with or without an underlying deck or sheathing.

1.2 The objective of this specification is to provide for the overall performance of the structural standing seam steel roof panel system as defined in 3.2.6 during its service life in order to provide weather protection, carry the specified design loads, and allow proper access over the roof surface in order to provide for periodic maintenance of equipment by the owner.

1.3 In addition to structural, the specifier shall evaluate other characteristics beyond the scope of this specification that affect the final choice of roof construction. These include, but are not limited to, functional, legal, insurance, and economic considerations. See Appendix X1 for specifier's checklist.

1.4 The specification is not intended to exclude products or systems not covered by the referenced documents.

1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 The text of this specification contains notes and footnotes that provide explanatory information and are not requirements of this specification.

2. Referenced Documents (purchase separately)

ASTM Standards
A463/A463M Specification for Steel Sheet, Aluminum-Coated, by the Hot-Dip Process
A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvanealed) by the Hot-Dip Process
A792/A792M Specification for Steel Sheet, 55 % Aluminum-Zinc Alloy-Coated by the Hot-Dip Process
A875/A875M Specification for Steel Sheet, Zinc-5 % Aluminum Alloy-Coated by the Hot-Dip Process
C711 Test Method for Low-Temperature Flexibility and Tenacity of One-Part, Elastomeric, Solvent-Release Type Sealants
C765 Test Method for Low-Temperature Flexibility of Preformed Tape Sealants
C879 Test Method for Release Papers Used with Preformed Tape Sealants
D1667 Specification for Flexible Cellular Materials--Vinyl Chloride Polymers and Copolymers (Closed-Cell Form)
D3310 Test Method for Determining Corrosivity of Adhesive Metals
E631 Terminology of Building Constructions
E1592 Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference
E1646 Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
E1680 Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems
G21 Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi

Underwriters Laboratories Standard
580 Standard for Safety, Tests for Uplift Resistance of Roof Assemblies

Index Terms

anchorage; clips; coatings; construction; deflection; endlaps; environmental; exposed; exposure; fasteners; flashings; galvanized; installation; joints; loading; loads; low-sloped; metal; oil canning; panels; penetrations; ponding; roof; sealer; seismic; service life; sidelap; slope; snow; standing seam; steel; structural; superimposed; tapes; thermal; uplift; water; weathertightness: Roofing materials/applications--specifications; Roof panel systems; Standing steel roof panel systems; Structural steel (SS)--specifications;

ICS Code

ICS Number Code 91.060.20 (Roofs)

DOI: 10.1520/E1514-98R11

ASTM International is a member of CrossRef.

Customer comments

No comments were found for ASTM E1514 - 98(2011) standard specification for structural standing seam steel roof panel systems. Be the first to comment!