ASTM International

ASTM E1530 - 11 standard test method for evaluating the resistance to thermal transmission of materials by the guarded heat flow meter technique


Source: ASTM International

This test method is designed to measure and compare thermal properties of materials under controlled conditions and their ability to maintain required thermal conductance levels.

1. Scope

1.1 This test method covers a steady-state technique for the determination of the resistance to thermal transmission (thermal resistance) of materials of thicknesses less than 25 mm. For homogeneous opaque solid specimens of a representative thickness, thermal conductivity can be determined (see Note 1). This test method is useful for specimens having a thermal resistance in the range from 10 to 400 × 10-4 m2•K•W-1, which can be obtained from materials of thermal conductivity in the approximate range from 0.1 to 30 W•m-1•K-1 over the approximate temperature range from 150 to 600 K. It can be used outside these ranges with reduced accuracy for thicker specimens and for thermal conductivity values up to 60 W•m-1•K-1.

Note 1—A body is considered homogeneous when the property to be measured is found to be independent of specimen dimensions.

1.2 This test method is similar in concept to Test Method C518, but is modified to accommodate smaller test specimens, having a higher thermal conductance. In addition, significant attention has been paid to ensure that the thermal resistance of contacting surfaces is minimized and reproducible.

1.3 The values stated in SI units are to be regarded as standard. The additional values are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)

ASTM Standards
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions
E220 Test Method for Calibration of Thermocouples By Comparison Techniques
E1142 Terminology Relating to Thermophysical Properties
E1225 Test Method for Thermal Conductivity of Solids by Means of the Guarded-Comparative-Longitudinal Heat Flow Technique
F104 Classification System for Nonmetallic Gasket Materials
F433 Practice for Evaluating Thermal Conductivity of Gasket Materials

Index Terms

heat flow meter; heat flux transducer; thermal conductance; thermal conductivity; thermal resistance; thin specimen: Thermal transmission properties--steady-state; Thin material specimens/applications; Composites; Heat flow meter method; Heat flux transducer (HFT); Thermal conductance/conductivity; Thermal resistance/resistivity

ICS Code

DOI: 10.1520/E1530-11

ASTM International is a member of CrossRef.

Customer comments

No comments were found for ASTM E1530 - 11 standard test method for evaluating the resistance to thermal transmission of materials by the guarded heat flow meter technique. Be the first to comment!