gravimetric dust sampling News

  • ASTM E1560 - 11e1 Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    The NVR obtained by this test method is that amount which is available for release by wipers in normal use. Evaporation of the solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room temperature and test temperature has not been shown to result in significant variances. This test method may be more ...


    By ASTM International

  • ASTM E1560 - 11 Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    The NVR obtained by this test method is that amount which is available for release by wipers in normal use. Evaporation of the solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room temperature and test temperature has not been shown to result in ...


    By ASTM International

  • Unique dust monitors for any application

    The Latest TSI Sidepak Personal Aerosol Monitors Have Been Added To The Ashtead Technology Range Of Particulate Matter (PM) Monitors. “We Were So Impressed With The Unique Features Of These Instruments, That We Immediately Added Them To Both Our Rental And Sales Portfolios,” Says Ashtead’s Regional Sales Manager Josh Thomas. “Many Occupational Exposure Applications Are ...


    By Ashtead Technology Ltd

  • Casella continues to lead the way in occupational dust measurement

    The brand new CEL-712 Microdust Pro from Casella CEL (www.casellameasurement.com; 01234 844100) is a rugged, hand-held, data logging instrument for the real-time detection of airborne dusts, fumes and aerosols. Boasting the highest measurement range of any device of its kind currently available on the market, it features a unique filter that enables on-site ...


    By Casella

  • Casella introduces new dust monitoring survey tool

    Dust can be a problem in almost any industry, from bakeries to building sites, and the problem is gaining wider recognition from local authorities and the HSE. Casella CEL has responded with the introduction of an area dust monitoring survey tool that can download its data for monitoring and reporting and run without access to external power for up to 19 hours. Called the Dust Detective, the ...


    By Casella

  • Casella to show CEL-712 Microdust Pro for reliable real time detection of airbourne dusts, fumes and aerosols

    Casella CEL, Stand E53 Safety & Health Expo, NEC Birmingham 14-16 May 2013 Casella – global specialist in state-of-the-art occupational health and environmental risk measurement solutions – will be showing its newly launched CEL-712 Microdust Pro at  ...


    By Casella

  • Casella ETi Appointed by Digitel as UK & Ireland Distributor

    Casella ETi (UK) has been appointed by DIGITEL-Swiss air pollution measurement experts, as their United Kingdom and Ireland distributor. Digitel, the Swiss specialist for automatic aerosol, gas and wet-only samplers, has been manufacturing for over 35 years and specialises in High Volume Samplers such as the DHA-80, a fully gravimetric system to sample dust and aerosol particles for later ...


    By Casella

  • Play the percentages game!

    With budgets under pressure everywhere, the good news is that Casella is offering customers an incentive to upgrade their monitoring instrumentation. An old-for-new replacement scheme can save users up to 30% on new replacements, plus the company is offering a 50% reduction on its Microdust to encourage SHE professionals to work with real-time dust data. Real time dust monitoring allows you to ...


    By Casella

  • Casella ETI Appointed by Digitel as UK & Ireland Distributor

    Casella ETI, the UK's leading manufacturer of air quality, pollution detection and industrial emissions monitoring equipment, has been appointed by DIGITEL - Swiss air pollution measurement experts, as their United Kingdom and Ireland distributor. DIGITEL, the Swiss specialist for automatic aerosol, gas and wet-only samplers, has been manufacturing for over 35 years and specialises in High ...


    By Casella

  • ASTM D6552 - 06(2011) standard practice for controlling and characterizing errors in weighing collected aerosols

    The weighing of collected aerosol is one of the most common and purportedly simple analytical procedures in both occupational and environmental atmospheric monitoring (for example, Test Method D4532 or D4096). Problems with measurement accuracy occur when the amount of material collected is small, owing both to balance inaccuracy and variation in the weight of that part of the sampling medium ...


    By ASTM International

  • Real time monitoring using particulate samplers

    Ecotech is pleased to announce the release of a real time particulate module for use with its range of particulate samplers.High Volume Air Samplers are designed to sample ambient air through a pre-weighed filter for 24 hours after which the filter is weighed and PM concentration calculated. While there are approved methods for semi-real time monitoring such as the Tapered Element Oscillating ...


    By Ecotech Pty Ltd

  • A healthier attitude

    According to a series of recent surveys, occupational health is finally becoming as much a cause for concern as workplace safety. Neal Hill, Product Line Manager, Casella, looks at our changing attitudes to Health and Safety and at how innovative technology can help to reduce risks to occupational health. The approach to occupational Health & Safety is changing all over the world with an ...


    By Casella