nh3 analyser News

  • FTIR analyser reveals surprising solution

    Emissions analysers have to be checked annually by certified testers and during recent functionality tests for a Gasmet FTIR continuous emissions monitor (CEM) at a UK Energy from Waste plant, the Nitrogen Dioxide span check results were found to be incorrect. A subsequent investigation revealed surprising results that would not have been apparent had the plant been using traditional CEMs. NO2 ...


    By Quantitech Ltd

  • MCERTS for portable and fixed FTIR analysers

    Quantitech is delighted to announce that the Gasmet Continuous Emissions Monitoring System (CEMS II e) and the portable (DX4000) FTIR analysers have been awarded an MCERTS certificate (Sira MC030014/08) demonstrating compliance with the MCERTS Performance Standards EN15267-3 & QAL 1 as defined in EN 14181. The certificate demonstrates enhanced performance across an extended range of gases. ...


    By Quantitech Ltd

  • Gasmet raises the bar for emissions analysers

    Gasmet Technologies, the Finland based instrumentation manufacturer, has announced that its FTIR-based Continuous Emissions Monitoring System (CEMS) has received approval from TÜV, the international certification body, for the EN 15267-3 standard, which is more recent and more stringent than the existing German Type Approval and QAL1 certificate, EN14181. This means that the Gasmet CEMS is ...


    By Gasmet Technologies Oy

  • Certification boosts demand for FTIR multigas analyser

    Quantitech has experienced a surge in demand for the Gasmet portable FTIR emissions analyser, the DX4000. “We believe that this instrument is now the only portable FTIR with MCERTS certification, and this is driving demand for both instrument rental and sales,” says Dominic Duggan. The Gasmet DX4000 portable FTIR gas analyser is typically used in stack emissions monitoring, comparison ...


    By Quantitech Ltd

  • USEPA Approval received for Ecotech’s Trace Precursor Analysers

    Ecotech is pleased to announce that we have received USEPA Equivalent Method Approval for our range of trace Precursor Analysers as follows: EC9830T Carbon Monoxide Trace Precursor Analyser (RFCA-0992-088), EC9841T Oxides of Nitrogen Trace Precursor Analyser (RFNA-1292-090) and EC9850T Trace Precursor Sulfur Dioxide Analyser (EQSA-0193-092). Ecotech also has USEPA approval for our standard ...


    By American Innovations (AI)

  • USEPA Approval received for Ecotech’s Trace Precursor Analysers

    Ecotech is pleased to announce that we have received USEPA Equivalent Method Approval for our range of trace Precursor Analysers as follows: EC9830T Carbon Monoxide Trace Precursor Analyser (RFCA-0992-088), EC9841T Oxides of Nitrogen Trace Precursor Analyser (RFNA-1292-090) and EC9850T Trace Precursor Sulfur Dioxide Analyser (EQSA-0193-092). Ecotech also has USEPA approval for our standard ...


    By Ecotech Pty Ltd

  • Latest multigas FTIR analysers can be hired

    FTIR gas analysers have become popular in a wide variety of gas detection and monitoring applications because of their ability to measure almost any gas. However, the cost of this equipment can exceed the budgets of those that could benefit from this sophisticated technology, so Quantitech has established a small range of FTIR gas analysers that are available for hire. Typical applications for ...


    By Quantitech Ltd

  • New Product Launched - The atmosFIR CEM

    The atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19" FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, ...


    By Protea Limited

  • Unique Engine Analysis System Now Offered

    Environnement SA (France) now offer heated, turnkey, gas analysis systems which are very easy to use and perform fast, continuous and simultaneous measurement of NH3 and NOx in DeNOx applications. These systems are ideal for engines where SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) have been implemented. In DeNOx systems using urea injection with ammonia (NH3) ...


    By Environnement S.A

  • FTIR for CEM’s and VOC’s monitoring

    As major contributors to environmental emissions, the waste incineration and power generation industries require both continuous and periodic emissions monitoring to ensure each plant is within Emission Limit Values (ELVs). FTIR provide to perform emissions monitoring solutions for the range of standard incineration or “combustion” gases, both inorganic species such as CO, NOx, SO2, ...


    By ETG Risorse e Tecnologia

  • EN 15267 Approved Mercury Monitoring System

    The measurement of total gaseous mercury is a challenge due to chemical reactions and contamination. The installed systems will often require a lot of maintenance, still not giving reliable results. The OPSIS System 400 is different and provides the plants with an accurate mercury analyser, that will operate with a minimum of maintenance. The simple design gives high performance with fast ...


    By Opsis AB

  • New TDL laser based gas analyzer launched

    Environnement S.A introduces the following state-of-the-art laser based analysers to cover number of applications for CEMS regulatory as well as process control such as: Coal Fired Boiler HCl Measurement on Dry FGD Scrubber Stack, Brick manufacturer HCL Stack Measurement, Incinerator HCl Measurement, Aluminium Smelter HF Measurement, Coal Fired Boiler SNCR NH3 Measurement, Cement plant HCl ...


    By Environnement S.A

  • Transportable CEMS can be hired

    The MCERTS approved Gasmet DX4000 transportable FTIR gas Continuous Emissions Monitoring System is available for hire from Quantitech. Able to monitor multiple gases simultaneously even in emissions that are hot, corrosive and high in moisture, the DX4000 is ideal for a wide variety of gas analysis applications. Quantitech's Dr Andrew Hobson says "The DX4000 is popular for renting because of its ...


    By Quantitech Ltd

  • Stack emission monitors are ‘future-proof’, says Quantitech

    Leading instrumentation company Quantitech is able to offer customers a revolutionary ‘future-proof’ gas analyser which can protect against any requirements to monitor new parameters in the future. The FTIR Gasmet DX-4000 can monitor up to 300 different compounds of varying concentration and other gases can be added for future applications at little or no extra cost, creating a ‘future-proof’ ...


    By Quantitech Ltd

  • Monitoring at biomass plants should be `future proof`

    The recent rise in approvals for the construction of renewable energy plants burning biomass has highlighted the need for specified monitoring equipment to be both cost-effective and flexible. Quantitech Director Dominic Duggan explains: “Whilst biomass power represents an important part of the Government’s strategy to produce energy from renewable sources and to reduce waste to landfill, a ...


    By Quantitech Ltd

  • Air pollutant emission limits exceeded in twelve EU Member States

    Twelve Member States exceeded one or more of the emission limits set by the EU National Emission Ceilings (NEC) Directive, according to recent official data for 2010 reported to the European Environment Agency (EEA). In some instances the limits were exceeded by significant amounts. For the first time, preliminary data recently reported to the EEA by Member States allow a comparison ...

  • Don`t waste the waste

    Biogas analysis cannot be underestimated: get it right and protect revenues, get it wrong and those revenues will quickly plummet There is no denying that biogas is valuable. It may not be the most pleasant material to handle — hot, wet, dirty, smelly, corrosive, toxic — but handled correctly, it is worth a lot of money to whomever is producing it. Encouraged, subsidised, ...


    By Geotech

  • Industrial air pollution cost Europe up to €169 billion in 2009, EEA reveals

    Air pollution from the 10,000 largest polluting facilities in Europe cost citizens between € 102 and 169 billion in 2009. This was one of the findings of a new report from the European Environment Agency (EEA) which analysed the costs of harm to health and the environment caused by air pollution. Half of the total damage cost (between € 51 and 85 billion) was caused by just 191 ...

  • Keep an eye on everything with LabMonitoring

    HORIBA’s newly developed data preparation tool allows users to extensively display and document the interplay of different HORIBA ONE PLATFORM devices as well as to influence the processes with regard to quality control. Growing challenges with regard to environmental policy have profoundly changed the demands made on vehicle and engine emissions measurement in the last few years. For ...


    By HORIBA Europe GmbH

  • Learn More About our Project Consultancy at AQE 2013

    Formerly known as MCERTS show, the 7th in the series titled Air Quality & Emissions Show 2013 (AQE) will look at both emissions to air monitoring and industrial emissions monitoring. Across the 2 days there are over 50 exhibitors as well as a series of free workshops and talks. After the success of 2011 MCERTS event a1-cbiss are returning for the bi-annual event in 2013. Teaming with ...


    By a1-cbiss

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you