Automotive production at the TOYOTA MOTOR CORPORATION site in St. Petersburg, Russia, results in various types of wastewater, which must be treated before they are discharged into the sewage system.
The Envochem® COL wastewater treatment plant has been designed for the automatic and continuous treatment of three streams of wastewater containing heavy metal, oil or no contaminants. The total volumetric flow is 50 m³/h. The treatment comprises the following process steps:
- Wastewater buffering and ventilation
- Precipitation / Flocculation
- Neutralisation
- Sedimentation
- Flocculation filtration
- Sludge dewatering using a chamber filter press
Performance data
- Overall plant capacity: max. 50 m³/h
- Wastewater containing heavy metals: max. 20 m³/h
- Wastewater containing oils: max. 20 m³/h
- Uncontaminated wastewater: max. 10 m³/h
Technical specifications
- Space requirements: 30 x 30 m
- Filter press volume : 440 l
- Filter press system: automatic CFP
- Control system: PLC S7 300