Only show results in Virginia? Ok

GC equipment

  • Premium

    LNI - Model GC - Zero Air Generators

    GCs is not sold any more by LNI Swissgas SA since end of December 2016.Warranty, services and spare part are still available at LNI SwissgasReplacement product : ZA FID AIR

    By LNI Swissgas SA based in Versoix, SWITZERLAND. from Gas Generators Product line

  • Premium

    Model GC - Refrigerant Gas Dryer

    Biogas always contains water vapour in an unsaturated state. During combustion, the water vapour results in considerable corrosion damages to the gas engines and turbines. Malfunctions caused by these damages lead to significant downtimes and high repair costs. The use of a gas dehumidification systems can considerably extend the engines’ service ...

    By Bilgeri EnvironTec GmbH based in Fussach, AUSTRIA. from Biogas Treatment / Biogas Conditioning Product line

  • Premium

    Pollution - Model Micro GC GCX - Micro Gas Chromatography Modular System

    Based on the micro gas chromatography technology, the GCX is an instrument that finds its best use on-line. Due to its configuration can be placed in 19.

    By Pollution Analytical Equipment based in Budrio (Bologna), ITALY. from Other Products Product line

  • Premium

    Model 28663-U - SPB-624 Capillary GC Column

    L × I.D. 60 m × 0.53 mm, df 3.00 μmGeneral description Application: This column is specially tested for separation, efficiency, and low bleed. It is designed for purge-and-trap analyses of volatile halogenated, non-halogenated, and aromatic contaminants from environmental samples. USP Code: This column meets USP G43 requirements. Phase:• ...

    By Merck based in Darmstadt, GERMANY. from SPB-624 GC Columns for Volatiles Product line

  • Premium

    Model 25430 - SPB-624 Capillary GC Column

    L × I.D. 30 m × 0.53 mm, df 3.00 μmGeneral description Application: This column is specially tested for separation, efficiency, and low bleed. It is designed for purge-and-trap analyses of volatile halogenated, non-halogenated, and aromatic contaminants from environmental samples. USP Code: This column meets USP G43 requirements. Phase:• ...

    By Merck based in Darmstadt, GERMANY. from SPB-624 GC Columns for Volatiles Product line

  • Premium

    Model 28463-U - VOCOL Capillary GC Column

    L × I.D. 20 m × 0.18 mm, df 1.00 μmGeneral description Application: This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems. USP Code: None Phase:• Bonded•

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Model 25358 - VOCOL Capillary GC Column

    L × I.D. 105 m × 0.53 mm, df 3.00 μmGeneral description Application: This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems. USP Code: None Phase:• Bonded•

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Model 24157 - VOCOL Capillary GC Column

    L × I.D. 60 m × 0.32 mm, df 3.00 μm General description Application: This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems. USP Code: None Phase:• Bonded• P

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Model 24217-U - VOCOL Capillary GC Column

    L × I.D. 60 m × 0.32 mm, df 1.80 μmGeneral description Application: This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems. USP Code: None Phase:• Bonded• Pr

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Model 25320-U - VOCOL Capillary GC Column

    L × I.D. 30 m × 0.53 mm, df 3.00 μmGeneral description Application: This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems. USP Code: None Phase:• Bonded• Pr

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Polaris - Compact and Portable Probe

    Polaris FID is well known to be the most portable FID analyser for stack monitoring. This probe represents the best accessory that matches Polaris FID portability. Built in with high quality materials, Polaris Probe is lightweight, compact and robust. According to EN12619:2013, a separate inlet port placed before the filter element allows zeroing ...

    By Pollution Analytical Equipment based in Budrio (Bologna), ITALY. from Micro GC GCX - Accessories Product line

  • Premium

    Pollution - Model MPX - Multipoint Sampler

    The instrument manages 8, 16, 24 or 32 sampling points. It has a rack shape in order to be easily fitted in normal industrial racks and better integrated with existing systems. MPX is equipped with 4-button keypad display for dialogue with the user and for manual control. The display always shows the selected and active point and shows the any ...

    By Pollution Analytical Equipment based in Budrio (Bologna), ITALY. from Micro GC GCX - Accessories Product line

  • Premium

    Pollution - Model VEGA-MPS - Multipoint Sampler

    Vega-MPS can be connected to 8, 16 or 24 sampling lines, depending on the model. Vega-MPS connects the micro-gaschromatograph to up to 30 sample points in a wide range around the instrument, through inert PTFE or steel pipelines. A pump sucks continuously from all lines, and a multi-point valve connects them cyclically to the ...

    By Pollution Analytical Equipment based in Budrio (Bologna), ITALY. from Micro GC GCX - Accessories Product line

  • Premium

    Pollution - Model EDU-3 - Enrichment and Desorption Unit - Air Sampling

    This device can be connected to Vega-GC (or between Vega-GC and Vega-MPS) to increase the concentration of air samples, improving the GC sensitivity. It is based on the widely used technique of adsorption and thermal desorption from a cartridge containing an active phase, which selectively traps a family of components (aromatics, oxygenated ...

    By Pollution Analytical Equipment based in Budrio (Bologna), ITALY. from Micro GC GCX - Accessories Product line

  • Premium

    Model 28664-U - SPB-624 Capillary GC Column

    This column is specially tested for separation, efficiency, and low bleed. It is designed for purge-and-trap analyses of volatile halogenated, non-halogenated, and aromatic contaminants from environmental samples. Dimensions: L × I.D. 105 m × 0.53 mm, df 3.00 μm

    By Merck based in Darmstadt, GERMANY. from SPB-624 GC Columns for Volatiles Product line

  • Premium

    Model 24256 - SPB-624 Capillary GC Column

    L × I.D. 60 m × 0.25 mm, df 1.40 μmGeneral description Application: This column is specially tested for separation, efficiency, and low bleed. It is designed for purge-and-trap analyses of volatile halogenated, non-halogenated, and aromatic contaminants from environmental samples. USP Code: This column meets USP G43 requirements. Phase:• ...

    By Merck based in Darmstadt, GERMANY. from SPB-624 GC Columns for Volatiles Product line

  • Premium

    Model 24129-U - Capillary GC Column

    This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems.

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Model 28662-U - SPB-624 Capillary GC Column

    L × I.D. 20 m × 0.18 mm, df 1.00 μmGeneral description Application: This column is specially tested for separation, efficiency, and low bleed. It is designed for purge-and-trap analyses of volatile halogenated, non-halogenated, and aromatic contaminants from environmental samples. USP Code: This column meets USP G43 requirements. Phase:• ...

    By Merck based in Darmstadt, GERMANY. from SPB-624 GC Columns for Volatiles Product line

  • Premium

    Model 24154 - VOCOL Capillary GC Column

    L × I.D. 60 m × 0.25 mm, df 1.50 μmGeneral description Application: This intermediate polarity column, designed for analyses of volatile organic compounds (VOCs), offers great retention and resolution of highly volatile compounds. Use this column in direct injection ports or coupled to purge and trap systems. USP Code: None Phase:• Bonded• Pr

    By Merck based in Darmstadt, GERMANY. from VOCOL GC Columns for Volatiles Product line

  • Premium

    Model 24105-U - SP-2331 Capillary GC Column

    L × I.D. 60 m × 0.32 mm, df 0.20 μmApplication: A highly polar cyanosiloxane column specially tested for analyses of dioxins, specifically tetrachlorodibenzodioxin (TCDD) isomers. Because the phase is stabilized, it has a maximum temperature slightly higher than non-bonded cyanosiloxane columnsUSP Code: nonePhase:• Stabilized • Proprietary Te

    By Merck based in Darmstadt, GERMANY. from SP-2331 GC-MS Columns for Dioxins Product line

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you