Accessor - Model 4000 - Digital Access Control System
The Accessor 4000 turns any existing key lock into a complete access control system. Whether you need to monitor access to a building, specific office, or a fenced site, the Accessor offers complete control over who enters, and when. Each self-contained key box can be programmed with up to 1,000 access codes. With the easy to use ACE software, you have complete access control with scheduled entry times and up to 5 levels of access. Each entry is retained in the audit log for easy retrieval of all user information.
-
Most popular related searches
Details
For 2001 we've added the ability to use the Accessor 4000 in stand alone mode; no need to connect it to a computer...ever. You can now add and delete users right from the keypad. To make full use of all the Accessor 4000 features, including entry logging, scheduled access and temporary users, you'll still want ACE, our easy to use, free software for the PC.
The self-contained, battery operated unit requires no wiring, and is easily installed next to any door or lock. Several models are available for mounting on chain link fences including our unique Gate/Fence model that replaces the padlock on fences secured with chains. Weather and vandal resistant housings insure security and make the Accessor 4000 perfect for either indoor or outdoor applications.
With the Accessor 4000, you control access to secured areas, establish entry schedules, and keep complete records of all users, all without the hassle of lost keys or rekeying.
Easy to Use...
- Enter your code
- Open the Accessor to gain access to your key
- Provides access control to any entry with an existing lock
- Battery operated and fully self-contained
- No electrical wiring required, saves time and money on installation
- Easy retrofit, installs next to any door or lock, even padlocks
- Suitable for indoor and outdoor use
- Eliminates the need to carry keys or cards
- Eliminates lost keys and lock rekeying
- Easy to program
- Limit user access days and times
- Easily add and delete temporary employees
- Audit logging lets you find out who entered and when
- Add user at the Accessor
- Delete users at the Accessor
- Supports up to 1000 users
- Nonvolatile memory
- Year 2000 compliant
- Removable dust cover for indoor use
- Durable metal housing and keypad
- Large key compartment suitable for several keys
- Precision machined latch mechanism
- Easily accessable serial port
Software
Managing access codes, creating group schedules and retrieving entry information is all handled through ACE software. Create new users, including temporary ones whose code only works as many times as you want on the dates you want. Track and sort users by name, change their access codes or level, even prevent access when they're on vacation.
Now with V2.0, setting up the Accessor is even easier. You can share only the users you want between boxes. No more creating a file for each box even though most of the users are the same. All you need to do is drag and drop users into a box or group to add them.
Once the ACE file is complete, simply connect the Accessor to the PC via the serial cable and download the information. Retrieving logs is equally easy, providing you a detailed record of all entries or attempted entry at each Accessor.
ACE V2.0 makes handling logs easier too. They are now filed automatically and displayed in the browser on the left side of the screen, under the box they came from. Just click on a log to view it.
- 20MB Hard Disk space
- Windows® 2000, Windows XP, Windows Vista, Windows 7
- USB port (serial port required for use with older Accessors)
- Easy to program
- Alphanumeric codes
- Code length 4 to 7 digits
- Supports up to 1000 users
- Weekly access schedules for up to 8 different groups
- Programmable holidays to restrict access
- Make users inactive without deleting them
- Temporary use codes for service personnel available
- Retrieve, view and save an audit trail of user entry, date and time of entry
- Automatic adjustment for daylight savings
- ACE files password protected with four different authorization levels
- Easy importing of text files
- Merge ACE files
- Programs an unlimited number of Accessors
- Pre-configure an ACE file for distribution to multiple sites
- On-line Help and tutorials
- Year 2000 compliant
- Free upgrades available via the Web
Specifications
- Access Code Capacity up to 1000 codes/users
- Access Codes 4 to 7 digit code entered at Accessor keypad to gain access to key compartment or activate an electric strike
- Access Levels 5 access levels, each user is assigned an access code & access level, no limit to number of users with a particular access level (other than max # of users)
- Level 1: Master - unrestricted access, can delete any Level 2-5 user code at the Accessor, can add Level 2-4 user code at the Accessor (New 2001)
- Level 2: Emergency - unrestricted access
- Level 3: Supervisor - unrestricted access, can delete any Level 4-5 user code at the Accessor, can add Level 4 user code at the Accessor (New 2001)
- Level 4: Worker - access restricted based on Group Schedules, vacations and Level 4 Lockout
- Level 5: Temporary User - restricted access dates with a limited number of entries allowed in addition to Level 4 restrictions
- Vacations each Level 4-5 user may have up to 4 vacation periods during which they are denied normal entry access
- Group Schedules up to 8 user groups for Level 4 & Level 5 users; each group has a schedule of times, days of the week & holidays during which group members are allowed access
- Holidays list of dates access may be denied to Level 4-5 users through Group Schedules
- Level 4 Lockout Level 1 and Level 3 codes can be used to deny normal entry access to Level 4 & Level 5 users (New 2001)
- Tamper Lockout inhibits unauthorized code 'guessing' by ignoring keypresses after detecting multiple invalid codes being entered
- Daylight Savings Time automatic or manual Accessor clock adjustments
- Low Battery Indication warbles on initial keypress when low battery detected, operation continues for approx 500 entries after low battery indication begins
- Nonvolatile Memory all access codes, schedules and logs are stored in nonvolatile memory and are retained even without batteries
- Log Capacity log capacity is dependent upon the number of users, ranges from 4000 logged events @ 110 users to 2000 logged events @ 1000 users
- Logged Events all activity at the Accessor including normal entries and programming is logged, with user identity & date/time stamp
- Wall Latch Release valid Level 1 access code or the Release Wall Latch Code allows removal or installation of Accessor from wall mounting bracket
- Serial Communication Code authorizes Accessor serial communications with the PC
- 12-Key Keypad 0 to 9 keys for entering a code, CLR is the Clear key and FCN key is for Function Codes or when deleting a user
- Electric Strike Model activates a relay when a valid access code is entered, access to the key compartment is only allowed to Level 1, 2 and 3 users
- Battery Life one year / 35000 entries guaranteed over the -30¡ to +135¡ F operating temperature range, typically three years / 60000 entries in normal 60¡ to 80¡ F room temperature
- Warranty one year limited warranty
- Dimensions 5.5'tall x 3.2'wide x 2.8'deep
- Included With All Models owner's manual, wall mounting bracket, 4 lag screws, allen wrench, jumpstart cable
Product specifications are for 2001 Accessor 4000 using ACE V2.0 or later software. Specifications are subject to change without notice. Some features listed require the Accessor to be programmed using ACE software.
Customer reviews
No reviews were found for Accessor - Model 4000 - Digital Access Control System. Be the first to review!