AdvancedSense & DirectSense - Model TVOC - Multi-Gas PID Meters
From VOCs Monitoring
GrayWolf is transforming how to Measure, Data-Log and Report on worker and general environmental exposure levels. The AdvancedSense TVOC is a powerful data collection tool, packed with on-board application information and advanced documentation features; highly intuitive and Easy-To-Use.
-
Most popular related searches
Features
- VOCs, %RH, ºF/ºC and up to 3 specific gas sensors per probe
- Choice of PID sensors optimized for ppb or ppm VOC concentrations
- On-board list of 250+ compounds detected by the PID sensor
- On-screen info about common VOCs including typical indoor air sources, worker exposure limits and much more…
- Response factors for common compounds; display/log corrected VOC values
- Productivity tools: audio notes, text notes, data file linked photos and more...
- WolfSense PC desktop data transfer & analysis software included
- Optional GrayWolfLive WiFi access to data & notes, with e-mail/text alerts when alarm conditions are exceeded
Specifications
- VOCs (SEN-B-VOC-PPMH PID sensor, 10.6eV lamp) Range: 0.1 to 10,000ppm
- 10.6 eV PIDs do not respond to VOCs with ionization potentials >10.6, such as methane (which at ~2ppm background is typically preferable not to measure), ethane or formaldehyde. However, they do respond to the vast majority of VOCs. Standard calibration is to Isobutylene. Users may calibrate to alternative VOCs.
- VOCs (SEN-B-VOC-PPB PID sensor, 10.6eV lamp) Range: 5 to 20,000ppb (user selectable units: ppb, ppm, µg/m3, mg/m3)
- Carbon Dioxide (TG-503 only) Range 0 to 50,000ppm, 0 to 5%
- Accuracy ±3% reading ±150ppm (alt 0-10,000ppm range; Acc ±3% reading ±50ppm)
- Relative Humidity: Range: 0.0 to 100.0 %RH
- Accuracy: ±2%RH80%RH)
- Temperature: Range: 5.0° to 160.0°F (-15° to +70°C)
- Accuracy: ±0.3°C
- Response Time: VOC, %RH, CO2 and °F/°C sensor
- All exhibit 90% response
- Probe Dimensions: 2in. (5cm) dia. x 12.5in. (30cm) lgth.
- Weight (probe): w/batteries 1lb. 10oz. (0.7kg)
- Probe Power: 2 x D cells; typical battery life 120+ hrs (60+ hrs for TG-503)
- Alternatively, power the sensors continuously from the meter/mobile
- PC or auto-switch when probe batteries are <20%
- Operating Range: 0 to 90 %RH (non-condensing), -15°C to 60°C
- Specific gas sensors may have a reduced operating range
- PC Software Requirements: Windows 8/7/XP
- Specify low (ppb) or high (ppm) range PID sensor. Add up to 3 electrochemical gas sensors per TG-502 probe, 2 per TG-503 (EC gas sensors n/a for VOC-103).
- Choose from:
- Note 1: Specialty mid-range VOC (200ppm, 2000ppm, 6000ppm) PID sensors are available
- Note 2: An NDIR CO2 sensor may also be added to the TG-503 probe
- Note 3: A CO/H2S combo sensor is also available (both gases from a single sensor)
- Note 4: HCl, EtO or NO cannot be installed in combination into a single probe
Order AS/DS TVOC kits with an AdvancedSense, WIN 8 tablet, or WolfPack included. Or order with software and connectors to operate with your own WIN 8/7/XP computer.
Advanced Report Generator software for automated, detailed reports, tripod kits, USB keys/cables for data download, %RH cal kits, and other accessories are available from GrayWolf.
Customer reviews
No reviews were found for AdvancedSense & DirectSense - Model TVOC - Multi-Gas PID Meters. Be the first to review!