Ametek Process Instruments - THERMOX

- Model TDLAS 5100 HD - Gas Analyzer

From

0

The Model 5100 HD hosts a dual laser platform. Two separate lasers are installed in the instrument, sharing a common optical path through the sample, enabling the measurement of two analytes simultaneously. This results in significant cost savings to our customers. Where the required concentrations of the analytes differ considerably such that different path lengths are required, two sample cells are used. Model 5100HD is also capable of dual stream analysis. Model 5100HD can measure any two combinations of water vapor, methane, hydrogen sulfide, carbon dioxide, and oxygen in process or flue gas.

Model 5100HD is designed to handle sample gases with high dew points. The standard version has its sample cell heated to a maximum of 100°C. A version is also available for 150°C.

A key feature of the Model 5100HD is the use of sealed reference cells, which contain known amounts of analyte gases measured, for referencing the emission wavelengths of the lasers. The use of reference cells enables both the ability to line-lock the lasers and to continuously verify the instrument calibration.

  • Laser Classification: Class 1m
  • Dynamic Range: 250 mAU (mili-Absorbance Units)
  • Limit of Detection: 0.1 mAU
  • Speed of Response:
  • Accuracy: ±1 mAU or ±2%, whichever is greater
  • Repeatability: ±1 mAU or ±2%, whichever is greater
  • Independent Linearity: ±1 mAU or ±2%, whichever is greater
  • Stability: 0.5% of full scale range
  • 24 hour zero drift:
  • Inputs: One non-isolated analog input configurable as 0-5 V or 0-20 mA, One optically isolated discrete DC input, Front panel keypad
  • Outputs: 4 line x 20 character alphnumeric VF display, Fast Ethernet (IEE802.3), RS485 serial port, isolated (supports Modicon MODBUS RTU), RS232 serial port (for service use only), Two isolated 4-20 mA analog outputs, Four dry contacts (contact rating 30VAC, 60VDC, 100VA resistive)
  • Electrical Requirements: 120VAC (108-132V); 47-63 Hz or 240 VAC (216-264V); 47-63 Hz
  • Power Requirements:
  • Sample cell pressure: 70-170 kPa absolute (10 to 25 psia)
  • Ambient temperature: -20ºC to +50ºC (-4ºF to +122ºF)
  • Ambient humidity: 0-90%, non-condensing
  • Maximum altitude: 2000 m
  • Pollution degree: 2
  • Sample flow rate: 1-10 lpm (2-20 SCFH)
  • Dimensions (HxWxD): 64.23 cm x 83.03 cm x 29.53 cm (25.29' x 32.69' x 11.63')
  • Weight: 60 kg (132 lb)

  • ATEX and IECEx Zone 2 T3 (T4 for 24 VDC version), CE, IP 65, NEMA 4X
  • INMETRO Certification for Zone 2 - Ex nA nC ic op is IIC T3 Gb, IP65
  • North American (NEC) Class I, II, III, Division 1 Groups B-D, F, G, T3, CE, IP65, NEMA 4X
  • Zone 1 (CEC)
Pending Certifications:
  • ATEX and IECEx Zone 1, IIB + H2, T3, CE, IP65, NEMA 4X