AppliTek AppliTOC - Series of On-Line Total Organic Carbon (TOC) Analyzers
Total Organic Carbon analysis has been classified as a non-specific analysis method to determine the organic load in water. Its inherent accuracy and speed, combined with a low cost of ownership make it a preferred (standard) analysis method in many countries and industries. The AppliTOC Series of On-line TOC Analyzers have been field-tested for many years in a wide range of applications and environments to determine organic compounds in water matrices.
-
Most popular related searches
Product Overview
The standard Total Organic Carbon configuration of the AppliTOC is in fact a measure of the non purgeable organic carbon (NPOC), while the volatile carbon (VOC) and the purgeable carbon (POC) are stripped out and lost for analysis. Although all UV/persulfate TOC analyzers employ similar basic techniques, AppliTek has challenged the boundaries of this technology. AppliTOC uses an adapted version of the standard TOC method in accordance with standard methods USEPA 415.2, ISO 8245 and DIN-EN 1484, by finetuning the oxidation process and optimizing its core performance.
Special configurations
The so-called “True TOC” is a special configuration of the AppliTOC which is a 100% measure of all organic carbon in the sample, and applicable when the ordinary TOC configuration does not satisfy your needs.
For hazardous areas, a special enclosure in stainless steel is available with all necessary connections, special analytics and control units, designed and certified to fully meet ATEX or NEC 500 directives.
Advanced Features
- Analytical mainframe can be configured to Total Organic Carbon, True Total Organic Carbon or, Total Inorganic Carbon or Total Carbon
- Smart features and add-on units reduce down-time and unnecessary checks substantially
- Built-in carbon removal system for purifying instrument air
- Unique range-specific solid state IR detectors with automatic zero calibration
- Up to three (6) sampling points possible
- Incorporated industrial PC with AppliTek controller software
Specifications
- Hot-aerosol UV / persulfate method
- One single range, factory set:
- 0 – 5 mg C/L 0 – 500 mg C/L
- 0 – 10 mg C/L 0 – 1,000 mg C/L
- 0 – 20 mg C/L 0 – 5,000 mg C/L
- 0 – 100 mg C/L 0 – 10,000 mg C/L
- Total Organic Carbon as non purgeable organic carbon (NPOC)
- Total Inorganic Carbon:
- TIC + POC + VOC
- Total Carbon:
- TC = NPOC + POC + VOC + TIC
- True TOC:
- TOC = NPOC + POC + VOC ― TIC
- 6 – 12 minutes (depending on range)
- Automatic, free adjustable sequence
- Automatic, free adjustable sequence
- Automatic, free adjustable sequence