Sometimes multiparameter monitoring is not required, this is where the AP-LITE comes in. This pocket sized Aquaprobe is designed to measure a single parameter, it consists of a small body with an optical electrode socket.
The AP-LITE Socket
This socket can house any of our 8 optical electrodes, which simply screw in and out.
Giving you a dedicated Turbidity sensor one day, and a standalone chlorophyll sensor the next!
Optical electrode options:
- Turbidity
- Chlorophyll a
- Blue Green Algae (fresh or salt water options available)
- Rhodamine
- Fluoresceine
- CDOM/FDOM
- Refined Oil
Some of the AP-LITE’s Features
Rugged Connection
All Aquaprobes feature the new AquaConn fully metal connectors. The AP-LITE features the all-metal AquaConn connectors. These high specification connectors feature large metallic key for a rigid fit, recessed pins for extra protection during pairing, guide markers on each part of the connector to allow you to instantly push the pair together in the correct alignment.
Continuous Turbidity Monitoring
Continuous Turbidity Monitoring
The AP-LITE can be used with our sapphire turbidity sensor for continuous monitoring. Because you do not have to manually take samples, as with other portable turbidity readers, the AP-LITE can be deployed for continuous monitoring. Using our BlackBox you cn even hook this up to existing networks or to a telemetry device.
Specifications
Standard Parameters
Dissolved Oxygen
- Range: 0 – 500.0% / 0 – 50.00 mg/L
- Resolution: 0.1% / 0.01mg/L
- Accuracy: 0 – 200%: ± 1% of reading. 200% – 500%: ± 10%
Conductivity (EC)
- Range: 0 – 200 mS/cm (0 – 200,000 µS/cm)
- Resolution: 3 Auto-range scales: 0 – 9999 µS/cm, 10.00 – 99.99 mS/cm, 100.0 – 200.0mS/cm
- Accuracy: ± 1% of reading
TDS*
- Range: 0 – 100,000 mg/L (ppm)
- Resolution: 2 Auto-range scales: 0 – 9999mg/L, 10.00 – 100.00g/L
- Accuracy: ± 1% of reading
Resistivity*
- Range: 5 Ωcm – 1 MΩcm
- Resolution: 2 Auto-range scales: 5 – 9999 Ωcm, 10.0 – 1000.0 KΩcm
- Accuracy: ± 1% of reading
Salinity*
- Range: 0 – 70 PSU / 0 – 70.00 ppt (g/Kg)
- Resolution: 0.01 PSU / 0.01 ppt
- Accuracy: ± 1% of reading
Seawater Specific Gravity*
- Range: 0 – 50 st
- Resolution: 0.1 st
- Accuracy: ± 1.0 st
pH
- Range: 0 – 14 pH / ± 625mV
- Resolution: 0.01 pH / ± 0.1mV
- Accuracy: ± 0.1 pH / ± 5mV
ORP
- Range: ± 2000mV
- Resolution: 0.1mV
- Accuracy: ± 5mV
Temperature
- Range: -5°C – +50°C (23°F – 122°F)
- Resolution: 0.01° C/F
- Accuracy: ± 0.5° C
Optional Parameters
Depth **
- Range: 0-60m (AP-2000 & AP-5000), 0 – 100m (AP-7000)
- Resolution: 0.01m
- Accuracy: ±0.5% FS (AP-2000 & AP-5000), ±0.2%FS (AP-7000)
**Option on the AP-2000. Comes as standard on the AP-5000 & AP-7000
Ion Specific Electrodes***
Ammonium
- Range: 0 – 9,000mg/L (ppm)
- Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 9,000 mg/L
- Accuracy: ± 10% of reading
Ammonia†
- Range: 0 – 9,000mg/L (ppm)
- Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 9,000 mg/L
- Accuracy: ± 10% of reading
Chloride
- Range: 0 – 20,000mg/L (ppm)
- Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 20,000 mg/L
- Accuracy: ± 10% of reading
Flouride
- Range: 0 – 1,000mg/L (ppm)
- Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 999.9 mg/L
- Accuracy: ± 10% of reading
Nitrate
- Range: 0 – 30,000mg/L (ppm)
- Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 30,000 mg/L
- Accuracy: ± 10% of reading
Calcium
- Range: 0 – 2,000mg/L (ppm)
- Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 2,000 mg/L
- Accuracy: ± 10% of reading
† Ammonium electrode required. Readings calculated from Ammonium, pH and temperature electrode values.
Optical Electrodes***
Turbidity
- Range: 0 – 3000 NTU
- Resolution: 2 Auto-range scales: 0.0 99.9 NTU, 100 – 3000 NTU
- Repeatability: ± 2% of reading
Chlorophyll
- Range: 0 – 500 µg/L (ppb)
- Resolution: 0.01 µg/L
- Repeatability: ± 2% of reading
Phycocyanin (Freshwater Blue-Green Algae)
- Range: 0 – 300,000 cells/mL
- Resolution: 1 cell/mL
- Repeatability: ± 2% of reading
Phycoerythrin (Marine Blue-Green Algae)
- Range: 0 – 200,000 cells/mL
- Resolution: 1 cell/mL
- Repeatability: ± 2% of reading
Rhodamine WT Dye
- Range: 0 – 500 µg/L (ppb)
- Resolution: 0.01 µg/L
- Repeatability: ± 5% of reading
Fluorescein Dye
- Range: 0 – 500 µg/L (ppb)
- Resolution: 0.01 µg/L
- Repeatability: ± 5% of reading
Refined Oil
- Range: 0 – 10,000 µg/L (ppb)
- Resolution: 0.1 µg/L
- Repeatability: ± 2% of reading
CDOM/FDOM
- Range: 0 – 2,000mg/L (ppm)
- Resolution: 2 Auto-range scales:
- 0.00 – 99.99 mg/L, 100.0 – 2,000mg/L
- Repeatability: ± 10% of reading or 2ppm (whichever is greater)