Environmental industry Equipment with Online monitoring solutions for the chlor-alkali industries applications available in Uzbekistan

  • Premium

    Determination of Oxygen in Hydrogen Outlet

    The determination of oxygen in hydrogen is a safety critical measurement to keep the hydrogen mixture below explosion limits during chlorine electrolysis. AppliTek’s analyzer system is engineered to detect oxygen in an early stage and safeguard the compression process, with a small footprint allowing easy integration in any production site.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Calcium and Magnesium in Hydrochloric Acid

    The purpose of monitoring calcium and magnesium levels in hydrochloric acid is to control brine acidification in chlorine electrolysis, which can be precisely monitored by means of AppliTek’s UPA Universal Process Analyzer.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-HCl - Determination of Chlorine in Hydrochloric Acid

    Chlorine levels in liquid hydrochloric acid (HCl) are precisely and safely monitored by means of AppliTek’s EZ-HCl process analyzer. On-line measurement of chlorine in liquid HCl guarantees the purity of the end product. An additional possible reason for the measurement is that chlorine is an indicator for the amount of excess hydrogen ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    TONI - Model Special - Total Ammonia in Brine

    The TONI “Special” on-line analyzer system has been developed to control nitrogen trichloride (NCl3) formation during the chlorine electrolysis process and thus reduce the risk of explosion incidents by high NCL3 concentrations. Traces of ammonia in brine may lead to formation of NCL3 in chlorine, including several nitrogen species ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Fast Determination of Hydrogen in Dry Chlorine

    Fast determination of hydrogen in dry chlorine provides an early warning system against elevated levels of hydrogen, thereby protecting the chlorine production plant against hydrogen explosion incidents. AppliTek’s analyzer system for fast determination of hydrogen in dry chlorine can be considered as Best Available Technology (BAT). ...

    By AppliTek NV based in Nazareth, BELGIUM. from System Integration Product line

  • Premium

    Determination of Oxygen in Dry Chlorine

    Levels of oxygen in dry chlorine in hydrochloric acid synthesis are monitored by means of an on-line analyzer system that can be equipped with two different measuring technologies: Alternating Pressure Paramagnetic or Tunable Diode Laser (TDL) analyzer system.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Oxygen in Hydrogen Feed

    AppliTek’s gas analyzer system allows to monitor and control precisely oxygen levels in the hydrogen feed of the HCl burner. The analyzer system can be equipped with either an electrochemical cell, by alternating Pressure Paramagnetic or with a Tunable Diode Laser (TDL).

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Hydrogen in Hydrogen Feed

    Levels of of hydrogen in the hydrogen feed of the HCl burner are reliably measured and controlled by means of AppliTek’s thermal conductivity analyzer system. The analyzer system is suited for use in hazardous environments and meets ATEX or NEC500 compliance standards.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Fast Determination of Oxygen in Wet Chlorine

    The purpose of fast determination of oxygen in wet chlorine is twofold: verification and control of membrane oxygen permeation, as well as to keep control of the oxygen-chlorine-ethylene explosion triangle. The technology behind AppliTek’s analyzer system for the fast determination of oxygen in wet chlorine is qualified as Best Available ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Hydrogen in Gas Vent

    Levels of of hydrogen in the gas vent of the HCl burner can be measured by means of AppliTek’s thermal conductivity analyzer system. The analyzer system is suited for use in hazardous environments and meets ATEX or NEC500 compliance standards.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-Autocal - Model pH - Ex Situ pH Metering

    The EZ-AutoCal pH assures fully automatic, accurate and reproducible pH measurements in a myriad of liquid applications where operators need to conduct routine measurements on a daily or even hourly basis. The analyzer performs measurements out of the process (ex situ) and batchwise, meaning that once the measurement is done and ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-Clarifier - Hydroxide and Carbonate in Unpurified Brine

    The EZ-Clarifier on-line analyzer system monitors levels of sodium hydroxide (NaOH) and sodium carbonate (Na2CO3) in the precipitation process of the primary brine purification. Controlling these levels guarantees low levels of impurities upstream and optimum control of brine purity. Prior to analysis, a proprietary preconditioning system samples ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-Settler - Settling System

    Sample preconditioning is not restrained to simply filtration but consists of several techniques to precondition a sample. The EZ-Settler is a special sample conditioning system designed for handling very dense liquid matrices such as saturated brine. The system automatically samples, settles and/or dilutes a liquid sample while only the ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-Brine - Calcium and Magnesium in Ultrapurified Brine

    With the introduction of membrane cells in the chlor-alkali industry, brine purity became very critical for optimal operation of electrolytic processes. An upset in the brine purification process, causing a sudden high concentration of calcium and magnesium impurities, can reduce the performance of the membranes and give rise to exorbitant ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    In-Line Turbidity of Prepurified Brine

    Measurement of the turbidity after the brine filter is a relatively simple yet effective upstream control measure of 1st step of the brine purification process guaranteeing low calcium and magnesium levels in the 2nd step of the purification process. Parameters: Turbidity.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-HCl - Determination of Iron in Hydrochloric Acid

    Levels of iron in liquid hydrochloric acid (HCl) are precisely monitored by means of the EZ-HCl analyzer system. Iron oxides that dissolve in the HCl can lead to the formation of ferrous chloride (FeCl2) and compromised purity of the end product.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    EZ-Chloride - Chlorides in Caustic Soda

    The EZ-Chloride on-line analyzer system is used in chlorine production plants to monitor precisely chloride levels during electrolysis. This approach guarantees quality of the NaOH end product and prevents premature failure of the membrane.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Impurities in Dry Chlorine

    The purpose of determining impurities in dry chlorine (after compression) is a quality control measure to avoid contamination and off-spec product batches. Alternatively, chlorine purity can also be determined by measuring absolute levels of chlorine in dry chlorine, by means of multi-wavelength UV analysis.

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Moisture in Dry Chlorine

    The purpose of determination of moisture in dry chlorine is threefold: prevent corrosion, prevent formation of ferric chloride and control the overall drying process. AppliTek offers two different solutions for determination of moisture: one traditional method by means of an amperometric phosphoric pentoxide (P2O5) electrochemical cell, ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

  • Premium

    Determination of Chlorine in Dry Chlorine

    Levels of chlorine in dry chlorine in hydrochloric acid synthesis are monitored by means of AppliTek’s multi-wavelength UV analyzer system. Hydrochloric acid or HCl is one of the primary products of the chlor-alkali industry and commonly produced by the exothermic reaction of hydrogen and chlorine inside a burner. With increasing concerns ...

    By AppliTek NV based in Nazareth, BELGIUM. from On-Line Analyzers Suite Product line

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you