AMETEK MOCON - Baseline

- Model 9000 H - Heated Hydrocarbon Analyzer

From

0

The Baseline 9000 H Heated Hydrocarbon Analyzer is a microprocessor based instrument designed for continuous ambient or process hydrocarbon gas measurement in environmental or industrial settings. The analyzer is configured for single point analysis (with or without a sample pump) of samples heated up to 376 °F (191 °C) for pre-filtered (< 10 microns) non-condensing samples.

Heated Gaseous Hydrocarbon Analyzer

  • EPA Method 25A
  • Accurate, continuous, detection
  • FlowGuard control of fuel, air, and sample with automatic shut-off
  • Graphical LCD display with easy to use menu

Detection limits down to < 0.1 ppm. User-programmable ranges from 10 ppm to 10% (propane) or 10 ppm to 50% (methane) are factory-configured per the customer’s application to facilitate installation and setup.

Using a Flame Ionization Detector (FID), AMETEK MOCON Baseline® FlowGuard electronic control regulates the delivery of fuel, air, and a small portion of the sample gas, to the FID. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized, detected by the instrument, and then reported as a concentration. The automatic calibration feature enhances the long-term analytical stability of the instrument.

All instrument parameters are reported clearly and continually refreshed on a large, graphical LCD display. Using analog, digital, and logic output communication capabilities, analytical information from the analyzer can be acquired using an external PC and a simple communications program such as Windows® HyperTerminal or the analyzer can output binary or ASCII formats directly to a data acquisition system or PLC. Every Baseline® 9000 H analyzer includes a AMETEK MOCON's free PC utility 9000 Keeper used for storing and uploading multiple methods, as well as sending configuration settings, directly to the analyzer.

Automated Control Features

  • FlowGuard control of fuel, air, and sample with automatic shut-off
  • Electronic back-pressure regulator with sample bypass system
  • Automatic FID ignition
  • Automatic calibration at user-defined intervals

Versatile Platform

  • Graphic LCD display with easy to use menu
  • Benchtop or rack-mountable
  • Ethernet or serial customizable output
  • Programmable analog output ranges
  • Programmable relays for diagnostics, concentration, alarms, and events

Baseline 9000 Heated Hydrocarbon Analyzer: Units

  • Detector: Flame Ionization (FID)
  • Ranges
    • User definable based upon calibration (as methane):
      • Very Low – 0.15 ppm to 200 ppm
      • Low – 0.3 ppm to 2,000ppm
      • Medium – 0.6 ppm to 20,000 ppm
      • High – 0.003% to 50%
  • Accuracy, Repeatability: ±1% full-scale
  • Drift, Zero: ±0.025% full-scale, 24 hours
  • Drift, Span: ±1% full-scale, 24 hours
  • Response Time: T90 < 5 seconds
  • Sampling: Internal single point, pump optional
  • Alarms: Multilevel concentration and fault alarms, audible and visual
  • Calibration: Programmable automatic or manual calibration
  • Support Gas Requirement
    • UHP Hydrogen (H2) – 30 cc/min
    • Zero Air – 175 cc/min
    • Span gas – methane is typical
    • Fuel blend options available
  • Display: Graphical LCD, 3.4” x 4.5” (8.64 cm x 11.43 cm)
  • Outputs, Standard
    • RS-232
    • LAN/Ethernet
    • Analog, 1 programmable 0-20mA/4-20mA isolated output
    • Relays, 5 programmable Form A relays rated to 3A @230VAC
  • Operating Temperature: 32 to 104°F (0 to 40°C)
  • Operating Humidity: 0 to 95% (non-condensing)
  • Configuration: Benchtop or 19” (48.3cm) rack-mount, 3U

Other Specifications (all models):

  • Physical Specifications
    • 5.25” H x 19” W x 16.25” D (13.02 cm x 48.26 cm x 41.28 cm)
    • <20 Lbs. (9.07 kg)
  • Electrical Requirements
    • Voltage: 100 - 240 VAC 50/60 Hz, 1 A

Preventive Maintenance Kit

  • Includes all parts potentially needed on-hand

Gas Generators

  • Hydrogen generators
  • Zero Air generators

Software

  • 9000 Keeper provided for method switching

Service & Support Options

  • Start-up and training, 1 day onsite

Environmental Monitoring

  • AMC in Cleanrooms
  • Air Quality Monitoring
  • Fugitive Emission Monitoring

Industrial Process Analysis & Control

  • Beverage Gas Monitoring
  • Industrial Gas Mixing Control
  • Process Gas Analysis
  • Specialty and Industrial Gas Monitoring
  • Surface Logging Analysis