Serinus Environmental industry Equipment
-
Serinus - Model 40 - Oxides of Nitrogen Analyser
The Serinus 40 Oxides of Nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL less than 0.4 ppb, range 0-20 ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace Product line
-
Serinus - Model 50 - Sulfur Dioxide (SO2) Analyser
The Serinus 50 Sulfur Dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL less than 0.3 ppb, Range 0-20 ppm). The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring networks for more than 35 ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace - SO2 Analyser Product line
-
Serinus - Model 50T - Trace Sulfide Dioxide (SO2) Analyser
The Serinus 50T trace sulfur dioxide (SO2) analyser delivers precise and reliable performance at excellent value. It uses proven pulsed UV fluorescent radiation technology to measure SO2 in ambient air (LDL 100 ppt, range 0 – 2000 ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace - SO2 Analyser Product line
-
Serinus - Model 40H - Oxides of Nitrogen Analyser
The Serinus 40H Oxides of Nitrogen Analyser uses microprocessor control and chemiluminescence detection to measure high concentration nitric oxide (NO), total oxides of nitrogen (NOx), and nitrogen dioxide (NO2). The Serinus 40H measures NO in the range 0-1000 ppm and NO2 in the range 0-150 ppm. The Serinus 40H analyser delivers excellent sensitivity and reliability by using a single measurement ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace - NOx Analyser Product line
-
Serinus - Model 10 - Ozone Analyzer
The Serinus 10 Ozone (O3) analyser delivers precise and reliable performance at excellent value. It uses proven non-dispersive ultraviolet (UV) absorption technology to measure O3 in ambient air (LDL < 0.5 ppb, range 0 – 20 ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace Product line
-
Serinus - Model 51 - Sulfur Dioxide (SO2) and Hydrogen Sulfide (H2S) Analyser
The Serinus 51 Sulfur Dioxide and Hydrogen Sulfide analyser delivers precise and reliable performance at excellent value. It combines pulsed fluorescence detection with an internal catalytic converter to sequentially measure H2S and SO2 in the range of 0-2/0-20 ppm respectively with a detection limit of 0.3 ppb. The Serinus range of analysers has been designed using our experience and knowledge ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace - H2S Analyser Product line
-
Serinus - Model 40T - Trace Oxides of Nitrogen Analyser
The Serinus 40T trace oxides of nitrogen analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology to measure NO, NO2 and NOx in ambient air (LDL less than 50 ppt, range 0 – 2000 ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace - NOx Analyser Product line
-
Serinus - Model 60 - Direct Nitrogen Dioxide Analyser
US EPA Designated Equivalent Method*. Ecotech presents the latest addition to the Serinus range: The Serinus 60 NO2 analyser with Cavity Attenuated Phase Shift (CAPS) spectroscopy technology. This technology allows direct measurement of nitrogen dioxide (NO2), rather than an indirect calculation from a chemiluminescence analyser. Using a modulated blue LED light source, the detector measures the ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace Product line
-
Serinus - Model 30 - Carbon Monoxide Analyser
The Serinus 30 Carbon Monoxide analyser delivers precise and reliable performance at excellent value. It uses proven NDIR gas filter correlation technology to measure CO in ambient air (LDL < 40 ppb, range 0 – 200 ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace Product line
-
Serinus - Model 31 - Carbon Dioxide (CO2) Analyser
The Serinus 31 carbon dioxide (CO2) analyser uses non-dispersive infrared (IR) gas correlation spectroscopy to provide accurate, stable, and repeatable measurements of gaseous CO2. The Serinus 31 can be configured to operate in absolute or differential mode providing flexibility within the analyser, making it well suited for ambient CO2 measurements in addition to applications such as dilution ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace Product line
-
Serinus - Model 44 - NO/NO2/NOX/NH3 Multi-Gas Ammonia Analyzer
The Serinus 44 analyser delivers precise and reliable performance at excellent value. It uses proven chemiluminescence technology and an external thermal catalytic converter to measure NO, NO2, NOx and NH3 in ambient air (LDL < 0.4 ppb, Range 0 – 20 ppm). The Serinus range of analysers has been designed using our experience and knowledge gained from operating large air quality monitoring ...
By Acoem based in Knoxfield, AUSTRALIA. from Gases - Ambient & Trace Product line
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you