SINEAX Environmental Industry Equipment
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Isolating amplifier for electrical isolation of DC signals. Processing of unipolar, bipolar and live-zero signals, load boosting and signal conversion ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Programmable Safety Value Converter for direct currents, direct voltages, temperature sensors, tele transmitters or ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Programmable multifunctional transmitter for currents, voltages, temperature sensors, remote transducers or ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Pt100, Ni100 / loop-powered converter: Input: Pt100 (- 200...+ 650 °C), Ni100 (- 60...+ 250 °C). Output: Current 4...20 or 20...4 mA. Max. consumption 24 mA. Measurement conversion 16 bit. Power supply range 5...30 V DC (loop-powered). Small dimensions (6.2 x 93.1 x 102.5 mm). Accuracy class 0.1% or 0.1 °C. Programming via dip-switch or ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The SINEAX VK616 is for installation into terminal housings at temperature sensors per DIN 43 729, type B. VK616 converts the measured quantity (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The purpose of the signal converter SINEAX TV815 is to electrically insulate input and output signals, respectively to amplify and / or change the signal leverl or type (current or voltage) of the input ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Isolating amplifier for electrical isolation of DC signals. Processing of unipolar, bipolar and live-zero signals. Load boosting and signal conversion ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
These devices convert the measured quantity (i.e. direct current or voltage, or the signal from a thermocouple, a resistance thermometer, a remote sensor or a potentiometer) into a proportional analog output ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The SINEAX V608 converts the measured quantity (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Pt100 to DC current / voltage isolator: Input: Pt100 (2, 3, 4 wires) (-150 °C...650 °C). Output: Current 0/4...20 or 20...4/0 mA or voltage 0...5/10, 10...0, 1...5 V DC. 3-way galvanic isolation. Spring-cage clamp connection. Power bridging terminal - DIN rail bus connector. Small dimensions (6.2 x 93.1 x 102.5 mm). Resolution of 14 bit. Accuracy class ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
DC current / Voltage converter: Input: Current 0/4...20 mA or voltage 0/1...5, 0/2...10, 0...15/30 V DC. Output: current 0/4...20, 20...4/0 mA or voltage 0/1...5, 0/2...10 V DC. 3-way galvanic isolation. Spring-cage clamp connection. Power bridging terminal - DIN rail bus connector. Small dimensions (6.2 x 93.1 x 102.5 mm). Resolution of 14 bit. Accuracy class ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
DC current / Voltage converter (with transducer power supply). Input: Current 0/4...20 mA or voltage 0/1...5, 0/2...10 V DC. Output: current 0/4...20, 20...4/0 mA or voltage 0/1...5, 0/2...10 V DC. 3-way galvanic isolation. Spring-cage clamp connection. Power bridging terminal - DIN rail bus connector. Small dimensions (6.2 x 93.1 x 102.5 mm). Resolution of 14 bit. Accuracy class ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Shunt / V-I isolated converter: Input: ± 25 mV up to ± 2000 mV. Output: current 0/4...20, 20...4/0 mA or voltage 0...5/10, 10...0 and 1...5 V DC. Max. consumption 22 mA. 3-way galvanic isolation. Resolution of 14 bit. Accuracy class 0.1%. Small dimensions (6.2 x 93.1 x 102.5 ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The SINEAX V624 converts measured quantities (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output quantity. ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Programmable multifunctional transmitter with very fast setting times for direct currents, direct voltages, temperature sensors, teletransmitters or ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The purpose of the signal converter / duplicator SINEAX TVD825 is to electrically insulate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Isolating amplifier for electrical isolation of DC signals. FSK compatible TV 808-115/116 variants with intrinsically safe output are especially well suited for controlling intelligent I-P converters in explosive atmospheres. The HART bypass allows for transmission of bidirectional FSK signals based on the HART ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The SINEAX V611 is a measuring transducer with 2-wire connection. It is suitable for temperature measurement in combination with thermocouples or resistance thermometers. Temperature sensor non-linearity is corrected ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
Potentiometric to DC isolating amplifier. Input: Resistor, Rheostat, Potentiometer. Output: Current or voltage. Accuracy: 0.2%. 3-way galvanic isolation. Screw-fit terminals (removable). DIN rail mounting. Power supply: 19...40 V DC, 19...28 V ...
-
Manufactured by Camille Bauer Metrawatt AGbased in SWITZERLAND
The digital indicator SINEAX A20 is an universal display device with a large OLED display for front panel mounting. About the two RS485 MODBUS RTU interfaces up to 30 measurement can be ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you