Analytik Jena  - an  Endress+Hauser Company

- Model SELMA - Precise and Semi-Automatic Pipettor

From

0

Precise and semi-automatic pipettor with 96 or 384 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

Semi-automatic 96- or 384-fold pipettor with Minimal required space
  • Precise
  • Replicable
  • Comfortable
  • Fast and precise processing of 96- and 384-well microplates without computer
  • Simple and intuitive handling with touch screen
  • Easy and fast tip changing with ready to use CyBio TipTrays
  • Error-free and reproducible results due to 96 or 384 parallel pistons and proven tip sealing principle
  • Reminder function and automatic use of pipetting heights and parameters for the processing of several microplates
  • An open design allows the use of external devices like shaker, vacuum chamber, heating adapters, etc.
  • Applications such as replication and reformatting of microplates as well as serial dilutions can be execute in seconds

Precise and semi-automatic pipettor with 96 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

Precise and semi-automatic pipettor with 96 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.



Precise and semi-automatic pipettor with 96 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

CyBio SELMA 96/25 µl
Semi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 0.5 till 25 µl and 2 working positions for 96 well plates

CyBio SELMA 96/60 µl
Semi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 1 till 60 µl and 2 working positions for 96 well plates

CyBio SELMA 96/250 µl
emi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 5 till 250 µl and 2 working positions for 96 well plates

CyBio SELMA 96/1000 µl
Semi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 10 till 1000 µl and 2 working positions for 96 well plates

CyBio SELMA 384/25 µl
Semi-automated pipetting station, instrument system stand alone, including a 384 channel pipetting head from 0.5 till 25 µl and 2 working positions for 384 well plates

CyBio SELMA 384/60 µl
Semi-automated pipetting station, instrument system stand alone, including a 384 channel pipetting head from 1 till 60 µl and 2 working positions for 384 well plates

Pipetting heads: Precision* (cv in %)

  • 96/1000 µl pipetting head:
    • 25-100 µl ≤ 2%
    • 100-1000 µl ≤ 1%
  • 96/250 µl pipetting head:
    • 10-25 µl ≤ 2%
    • 25-250 µl ≤ 1%
  • 96- oder 384/60 µl pipetting heads:
    • 3-5 µl ≤ 2%
    • 5-60 µl ≤ 1%
  • 96- oder 384/25 µl pipetting heads:
    • 2-5 µl ≤ 2%
    • 5-25 µl ≤ 1%

*The specification of precision and trueness is based on the Analytik Jena internal gravimetric and photometric standard measurement procedure, which is published as Annex B7 in the ISO IWA 15 document ” Specification and method for the determination of volumetric performance of automated liquid handling systems“ (www.IWA15.org). The Application Note „Photometric and Gravimetric Liquid Handling Check Procedure to determine the Random Error (Precision) and the Systematic Error (Accuracy) of Automated Liquid Handling Systems (ALHS)“ describes this measuremet procedure in detail. Every modification of this method may influence the results.

  • Plate Replication
  • Plate Reformatting
  • Cell culture medium exchange
  • ELISA
  • Reagent addition
  • Plate coating
  • Dilution
  • DNA extraction
  • HTRF Assay

Customer reviews