- Model MIR FT - Multi-Gas Infra Red Fourier Transform (FTIR) Analyzer

From

0

With the emissions limits tightening and new gases being introduced, this monitoring system allows future gas upgrades, providing the solution for today and what may happen tomorrow. Designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), the MIR-FT offers maximum availability and complete compliance with QAL 1 of EN14181 & EN15267-3.

  • A single analyzer for the measurement of multiple gases : NO, NO2, NOx, N2O, CO, CO2, SO2, HCl, HF, CH4, TOC, NH3, H2O, O2 ...
  • Based on a leading edge technology for simultaneous, multigas measurement of: HCl, NO, NO2 (NOx), SO2, CO, CO2, HC, CH4 (TOC), NH3, HF, H2O...
  • Fast and simultaneous measurements of up to 50 parameters
  • Especially designed to measure wet and corrosive sample gases, including trace concentrations
  • Perfectly suited for hot/wet measurement of soluble gases such as HCl, HF, NH3
  • Excellent calibration stability
  • Automatic correction of spectral interferences
  • Unmatched accuracy and reliability
  • Rugged & insensitive to vibrations
  • Low maintenance required

  • Municipal, Industrial, Hospital waste incinerators (energy from waste)
  • Biomass, Cement Kilns, Pulp & Paper, Glass Plants
  • DeNOx (SNCR, SCR) applications
  • Power & Combustion.

Complete turnkey system, would normally comprise of:

  • Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement).
  • Heated sample line in association with HOFI, heated sampling system according to the application
  • Automatic calibration unit
  • Instrument Air drying system
  • Industrial PC with Windows based eSAM FT software for on-board data acquisition and processing
  • TOC measurement by FID possible, using the complementary Graphite 52M analyzer

  • QAL1 certified measuring range: please see the brochure (pdf above)
  • Zero drift: ± 1% full scale / 30 days
  • Span drift: ± 1% full scale / 30 days
  • Repeatability: ± 2% full scale
  • Lower detectable limit: 2% full scale
  • Resposne time:< 120s depending on the gas
  • Interferometer resolution: 8 cm-1
  • Measurement cell: multi-reflexion, 5 m
  • Power supply: 220 V, ± 15%, 50-60 Hz, 200 VA
  • Dim.: rack 19“, 616 x 483 x 220 mm (DxWxH)
  • Weight: 20 kg approx
  • Operating temperature: + 10°C to + 35°C

  • MCERTs certified to EN15267-3
  • QAL1 certified as defined in EN14181
  • QAL3 compliance to EN14181
  • U.S. EPA 40 CFR 60 and 75 Compliant

Customer reviews

No reviews were found for ENVEA (ex Environnement S.A) - Model MIR FT - Multi-Gas Infra Red Fourier Transform (FTIR) Analyzer. Be the first to review!