ENVEA

- Model AF22e e-Series - Sulfur dioxides Analyzer SO2

From

0

UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides(EN 14212). With its ultra low power consumption & 24 V supply (option), the AF22e is the sole SO2 monitor on the market able to measure without being connected to the power grid.

  • Superior metrological performances for SO2 measurements in ranges 0-10 ppm or 0-1 ppm
  • Innovative conception of the optical module for excellent sensitivity and signal stability
  • Real-time calibration graph, animated synoptic, auto-diagnostic, control and maintenance data screens can be displayed while the instrument is operating
  • Embedded Communication Protocol for XR® Software with automatic recognition and configuration
  • Able to withstand temperatures up to 45-50 °C without air conditioning
  • Special architecture means that no additional pump is necessary in case of permeation bench (in option)
  • Automatic recognition of plugged electronic boards or optional devices: plug & play principle
  • Smart, connected instrument with embedded web server for the easiest, full remote control and operation of the analyzer from any PC, tablet or smartphone (configuration, calibration, test, diagnostic parameters…)
  • Integrated web-server with full remote emulation of the analyzer through the ENVEA Connect free app

  • Continuous indoor and outdoor air quality monitoring
  • Stationary and mobile AQMS laboratories
  • Industrial fence-line monitoring
  • Continuous emissions monitoring (CEM) by dilution
  • Laboratory & field studies on SO2/H2S/TRS effects…
  • Background (urban or suburban) Rural, Traffic, Kerbside measurement campaigns and monitoring studies

  • Measured parameter: SO2
  • Technology: UV Fluorescense
  • US-EPA Approval / QAL 1 Certification: YES
  • Measurement ranges: 0-1 ppm or 0-10 ppm user-defined
  • Measurement units: ppb, ppm, µg/m3 user-defined
  • Lower Detectable Limit (2σ): < 0.4 ppb
  • Noise (σ): < 0.2 ppb
  • Zero drift: < 1 ppb / 24h
  • Span drift: < 0,5% / 7 days
  • Linearity: ± 1%
  • Sample flow rate: 20L/h
  • Sample pump: internal
  • Temperature range: 0°C to +35°C
  • Data storage: 1 year
  • Included I/O: 1LAN/3USB/WIFI/2DRY
  • Weight (Kg): 9,8
  • Dimensions mm (LxWxH): 483 x 606 x 133
  • Case: 19″ Rack, 3U
  • Power supply: ‘100~250Vac, 50/60Hz + ground
  • Pressure and temperature compensation: YES

Main Options:

  • TFT color touch screen (800 x 480 , 7″)
  • Additional parameter: SO2
  • 24 V Power supply PLUS extended temperature range 0-50°C

Compliance With:

  • 2008/50/EC, EN 14212, EN 15267, 40 CFR PART 53 SUB B and SUB C
  • QAL 1 certified by the TÜV to N° 0000051690
  • U.S. EPA approved as compliant with EQNA-0802-149
  • ENVEA monitoring solutions are European QAL 1 certified and in compliance with the latest international regulations & standards.
  • They are also approved and certified by various laboratories and organizations around the world such as: US EPA, TÜV, GOST, CEN, JQA, CNEMC, JMOE, KTL, CNSA, LCSQA

Customer reviews