AppliTek NV

- On-Line Microbiology Analyzer

From

0

The EZ-ATP monitors total bacterial and pathogen load in water by measuring portions of ATP (adenosine triphosphate) of any type of bacterial microorganism present in the water sample. These may include fecal coliforms such as E. coli, sulphate reducing bacteria, nitrifying bacteria or Legionella. The analyzer can be used as an Early Warning System in various applications with focus on water safety, when high ATP values indicate a potential risk in surpassing a threshold value of microorganisms in the past or in the near future.

Contrary to commonly available manual or semi-automated methods, EZ-ATP differentiates between intracellular and extracellular ATP levels and provides operators analysis results on:

  • Extracellular ATP or free ATP, representing the portion of ATP released by dead cells
  • Total ATP
  • Intracellular ATP, representing the portion of ATP from the metabolism of living microorganisms

Background

The perceived need for more rapid and reliable methods for measuring water quality, especially in the area of drinking water safety, has established new interest in the use of the ATP chemiluminescence. In a process environment, or for any process where the microbiological water quality is critical, corrective actions depend on timely data. Traditional plate counting methods take days for results to become available and this may be further increased by laboratory reporting times. The EZ-ATP On-line Microbiology Analyzer presents a unique alternative to current analysis procedures, taking the standard ASTM test method a step further.

  • Complying with internationally accredited ASTM D4012–81 standard test method
  • Rapid measurement: 10 minutes (including lysis)
  • No delay between sample take-off and measurement
  • No bias from the composition of the growth medium such as with plate counting
  • Complete ATP recovery: detection of intracellular, extracellular and total ATP
  • Low cost of analysis relative to a large number of results
  • Smart functions: automatic calibration and cleaning

Analysis method
  • Determination of content of microorganisms in water (Standard method ASTM D-4012 – 81)
Parameter
  • Adenosine Triphosphate
Measuring ranges
  • 0.5 – 250 pg/mL or 0 – 500 pM ATP
  • Lower ranges are available on request
Cycle time
  • 25 minutes (including lysis and cleaning)
Calibration
  • Manually, when changing reagents
Cleaning
  • Automatic, free adjustable sequence