F&J SPECIALTY PRODUCTS, INC.

- Model C14CS-3000 - Carbon 14 Collection System

From

0

The Model C14CS-3000 Tritium Collection System is a carbon 14 collection system consisting of a diaphragm pump, 12VDC brushless motor, two 500ml NaOH sampling vials with stainless steel caps and an overflow trap. The flow and volume of air passing through the system is adjusted and measured by a microprocessor controlled Digital Flow Meter (DFM). The DFM utilizes a precision-machined orifice to measure flowrate. The DFM displays on-board calculations on a bright large character LED display. Flowrate and totalized volume both corrected to a reference Temperature and Pressure and elapsed time are displayed.

Multiple operator selectable data download frequencies are available through the RS232 port for collection and/or storage of real-time data.

The unit is designed for continuous indoor or outdoor use. Please consult the product specifications for the design temperature range and the installation category.

The typical operating flow range can vary from 100 – 500 sccm or 500 – 1000 sccm.

  • Large, bright LED Display
  • Microprocessor controlled electronics
  • Flowrate measurements and volume totalizations are corrected to a factory settable reference Temperature and Pressure Classical STP 0ºC, 1 Atm Normal T and P 20ºC, 1 Atm Modified Normal T and P 70ºF, 1 Atm Standard Ambient T and P 25ºC, 1 Atm
  • Precision machined DP sensor
  • Flowrate accuracy within ± 4% F.S.
  • Flowrate / Volume Options: sccm / scc SLPM / SL
  • LED dimming feature
  • 100-120VAC,50/60Hz, single phase

  • PUMP TYPE: Diaphragm
  • MOTOR: 12VDC brushless motor
  • CAPACITY: Maximum 500 cc/min or 1000 cc/min
  • POWER REQUIREMENTS: 100 – 120VAC; 50/60 Hz; 1 ampere; single phase
  • CIRCUIT BREAKER PROTECTION: 5 amperes
  • ELECTRICAL CORD: All temperature, 3-wire, 16 gauge
  • DIMENSIONS: 23 cm × 61 cm × 51 cm
  • WEIGHT: 26 kgs
  • INSTALLATION CATEGORY: Pollution Degree 3
  • ELECTRONIC SPECIFICATIONS
  • MEASUREMENT ACCURACY
    • Air flow: ± 4% of full scale
    • Temperature: ± 0.9ºF (0.5ºC) (Not displayed)
    • Barometric Pressure: ± 0.6 inches Hg (Not displayed)
  • OPERATING TEMPERATURES: 32º - 122ºF (-17º - 50ºC)
  • STORAGE TEMPERATURE: 0º - 122ºF (-28º - 50ºC)
  • CALIBRATION: Calibration verification once per year
  • COMMUNICATIONS INTERFACES: RS-232
  • ON-BOARD CALCULATIONS
    • Flow calculation from differential pressure value corrected to a reference T and P
    • Elapsed Time
    • Cumulative Volume corrected to a reference T and P
  • OPTIONS:
    • Flash Card Data Storage Device 232FCDSD
    • Flash Card (2 GB) 372239
    • PC Flash Card Reader SDDR-199-A20
    • Ruggedized Phone System CASRPS-DFM

Customer reviews

No reviews were found for F&J - Model C14CS-3000 - Carbon 14 Collection System. Be the first to review!