DOD Technologies Inc

- Model DOD64 FTIR - Gas Detection System

From

0

The DOD64 FTIR is a Flexible 16 to 64 Point Sequential FTIR Monitor that provides field-proven Fourier-transform infrared spectroscopy (FTIR) Technology for the quick detection of low level toxic, corrosive and combustible gases. For a full list of detectable gases available on the DOD64 FTIR gas detection system, please contact DOD Technologies, Inc.

The DOD64 FTIR Gas Monitor offers a unique solution to today’s environmental monitoring needs. This system is integrated with all new state of the art controls and HMI systems.

The DOD64 FTIR new multipoint system makes FTIR monitoring more affordable per point and simplifies the operations through a well thought out, customer driven innovative engineering approach.

This new innovative gas detection system enables customers to experience advanced technology at a lower initial investment and reduced cost of ownership.

  • Advanced Interferometer
  • 16 – 64 Points of Detection
  • 20 gas selection per point
  • 50 Initial Gases to select from
  • DGTS or MCT Stirling cooled detector
  • Ceramic Globar IR Source
  • VCSEL reference laser
  • Sample Cell volume 400ml
  • USB Port with Memory Stick
  • Real-Time Trend Display
  • Complete Front Access
  • Touch Screen Control
  • Compact Size
  • Advanced HMI & Flash control

  • Increased reliability / Lower maintenance
  • Flexible & Expandable system
  • Cost-effective monitoring per point
  • Flexible to adapt to new requirements
  • Detects gases at a much lower level (PPB)
  • Increased reliability / Lower Maintenance
  • Increased reliability / Lower Maintenance
  • Quick sample fill time and analysis (min 10 sec.)
  • Easily retrievable data and spectra
  • Quick real-time information and spectra
  • Easy to service
  • Easy to start up and operate
  • Simple to install in existing layouts
  • More reliable and easy to learn

  • Detection Principle: FTIR
  • Gasses Available: See Next Page
  • Monitoring Points: 16 up to 64 (In 16-point increments)
  • Sample Distance: 400ft. (122m) - .25” OD, .187” ID Teflon FEP tubing
  • Exhaust Tubing: 25ft. (7.62m) -.375” OD, .25” ID Poly-E (Included)
  • Display: 19” Color touch screen
  • Local Alarm Indication: Visual on Display & Audible (Optional light tower available)
  • Relay Outputs: Programmable low and high-level faults
  • Operating Temperature: 40°F – 104°F (4°C – 40°C)
  • Dimensions: L x W x H - 59” (+10” For Tubing) x 31” (+9” for Wiring) x 28.5”
  • Shipping Weight: 450lbs. (204 kg)
  • Operating Voltage: 100 – 110VAC (50/60Hz), 230VAC (50Hz)
  • Power Consumption: Less than 6 Amps
  • Enclosure: Powder Coated Steel
  • Spectral Range: 4.0cm – 1
  • Infrared Source: Ceramic Globar at 1500 C
  • Reference Laser: VCSEL (Vertical Cavity Surface Emitting Laser) at 850nm
  • Detector: Stirling-Cooled MCT (Mercury Cadmium Telluride)
  • Line Flow: Continuous line purge
  • Line Sample Analysis: Sequential (As little as 10 secs per point)
  • Gas Cell Path Length: 10 Meters Effective Path
  • Gas Cell Construction: Nickel Coated Aluminum
  • Mirrors: ZnSe