Gasera - Model PA 301 - Ultra-High Performance Photoacoustic Detector for Solid, Semi-Solid and Liquid Samples
From Products
-
Most popular related searches
Products Details
Versatile analysis with ultra-sensitive photoacoustic FTIR accessory
Baseplate options
All major brands are supported
Connection to commercial FTIRs is provided by the baseplate
Changeable Window
UV-region, IR-region, NIR- region
Spectral region is defined by the window material (user changeable)
PA301 Accessory Box
Spectrum normalization
by carbon black reference. Comes with different size sample cups.
Products Details
- No sample preparation
- Contactless measurement
- 100x faster than other PAS solutions
Due to the ultra-high sensitivity of the Gasera novel cantilever sensor, high quality spectra can be obtained in just seconds unlike in other available photoacoustic accessories. In fact the PA301 is over 100x faster that other competing PA solutions in the market. Furthermore, ambient air can be used as the carrier gas to obtain a signal-to-noise ratio (SNR) that is still significantly better compared to other commercial photoacoustic detectors used with helium carrier gas.
The quickness and the ease of use make the PA301 a must-have accessory for every lab!
Applications
- Dark samples (eg. bitumen, rubber, etc.)
- Pharma quality control
- Soil samples
- Paper and wood analysis
- Oil analysis
- Tissue samples
- Food analysis
- Forensics
- Cosmetics
- Art Conservation
- Polymeers
- Paint and pigment analysis
- Gemstones
Product Contents
- Photoacoustic detector with focusing mirror
- Optical cantilever microphone with built-in laser readout interferometer
- Removable sample cups for solid, semi-solid, and liquid samples
- Carbon black reference
- Vibration isolated detector mounting
- Digital Signal Processing -module
- Power supply (+12 VDC)
- Cables to connect the modules and to connect to the FTIR instrument
- Gas connector for purge gas with automatic valve contol and built in flow meter
- Detector manual
- Storage case
Specifications
- Minimum detectable pressure variation in the PA301 sample cell: 2 μPa/√Hz (RMS)
- Microphone sensitivity: Approx. 10 V/Pa
- Rapid sample change without breaking the purge seal
- Analog interface: BNC cable to detector input on the FTIR
- Analog output: +/- 3.3 VDC interferogram signal
- DSP analog output gain range: 0.02 – 20 in 10 step
- Spectral range de?ned by window material (from UV to far-IR)
- Maximum sample size: 10 mm diameter, 9 mm height
- Helium purge with automatic purge valve operation
Customer reviews
No reviews were found for Gasera - Model PA 301 - Ultra-High Performance Photoacoustic Detector for Solid, Semi-Solid and Liquid Samples. Be the first to review!