- Model CEMS II - Continuous Emissions Monitoring System

From

0

Gasmet CEMS is a modular construction that typically comprises of Gasmet CX4000 FTIR gas analyzer, heated sampling unit, industrial PC and a Zirconia oxygen analyzer which are installed in an air-conditioned cabin. All modules are 19' rack mounted in pull-out shelves for easy accessibility & service. Gasmet CX4000 FTIR gas analyzer allows the simultaneous measurement of up to 50 gas compounds. Gasmet CX4000 FTIR has a multipass sample cell which is heated to 180 °C and features rhodium-gold plated mirrors.

Image
  • TÜV and MCERTS certified
  • QAL1/ EN 15267-3
  • Hot/wet measurement ofHCl, HF, NH3
  • Total Organic Carbon measured with FTIR
  • Low maintenance requirements

The hot-extractive sampling system consists of a heated sample gas probe, heated sample lines and heated sample pump unit. Two-stage particle filtration is used in order to remove particles from the sample gas. The sample pump unit includes gas connections for the Gasmet CX4000 FTIR gas analyzer, optional O2 analyser and span & zero gas.

The industrial PC is used processing & storing the sample spectra with Calcmet™ software. The Calcmet™ software analyzes the sample spectrum using sophisticated analysis algorithms. Cross-interference from other gases is automatically taken into account in the analysis settings of each compound. Since water content of the sample gas is measured, the results can be reported on either “wet” or “dry” basis. With Gasmet™ CEMS, TOC can be measured without an additional FID analyzer (as a sum of individual hydrocarbons).

Comprehensive I/O functions make possible to connect Gasmet CEMS II into all kind of automation or reporting systems. Measuring data and alarms can be transferred from Gasmet CEMS II to other systems with analog or digital format. Gasmet CEMS II is also equipped with analog / digital inputs for external data (other analyzers or process).

Gasmet CEMS II provides different alarm functions such as System alarm, Service request, Maintenance on progress (can be set also manually), Concentration alarm, and Result valid. Combination for each alarm can be set on Calcmet. If any of the critical alarm is activated, instrument air starts to flow automatically into the system to prevent condensation.

With FTIR measurement technology there is no need to do any span or re-calibrations, only zero calibration with nitrogen every 24 hours. Automated span checks are also supported as standard.

Typical application is H2O, CO2, CO, N2O, NO, NO2, SO2, HCl, HF, NH3, CH4, C2H6, C3H8, and C2H4 monitoring from waste incinerator or large combustion plants. Measured components and calibration ranges can be changed according to application.The Gasmet CEMS II is an ideal tool to use for measuring trace concentrations of pollutants in wet, corrosive gas streams. All parts of the Gasmet CEMS II are be heated up to 180 ºC. It can be used for undiluted gases and the sample gases do not need drying beforehand.

The Gasmet CEMS II includes all power connections and temperature controllers for heated lines and heated sample probe. The operation of the system is fully automatic and controlled by the Calcmet software. Additionally all functions of Gasmet CEMS II can be controlled manually.

Gasmet CEMS II is air conditioned with a compressor-cooling unit on top of the cabinet. Cabinet includes ready made through-leading rubbers on each side and top of the cabinet for all cables and lines. Gasmet CEMS II is also supported by full remote control. The Gasmet CEMS II FTIR has a very low cost of ownership; the equipment is extremely well designed, and requires very little maintenance. The system also has a number of in-built failsafe devices to protect the instrument from potential damage.

  • Low need for maintenance
  • No span calibrations required (automated span checks possible)
  • Hot-extractive-sampling; no sample loss or change of composition
  • Capability to water soluble compounds like HCl, HF, NH3, etc.
  • TOC (Total Organic Carbon) measured with FTIR
  • Fully automated measurement system with comprehensive safety functions
  • Ready for future requirements - new compounds can be added without any hardware changes
  • Fully modular system built to customer specification

  • Waste Incineration Plants (monitoring of H2O, CO2, CO, NOx, SO2, HCl, HF, TOC, O2)
  • Cement kilns (as above)
  • Power plants with De-NOx systems (monitoring of slip NH3 & SO2, NOx, CO, O2)
  • N2O monitoring at nitric acid plants
  • Brick and glass manufacturing
  • Aluminum and steel smelters
  • Greenhouse gas emissions of wastewater treatment

 TÜV (17th BlmSchV) and MCERTS certified. Fully compliant with U.S. EPA 40 CFR Part 60 Appendix b Performance Specification 15 (Extractive FTIR Continuous Emissions Monitoring Systems in Stationary Sources).

General parameters

  • Measuring principle: Fourier transform infrared, FTIR
  • Performance: Simultaneous analysis of up to 50 gas compounds
  • Response time, T90: < 180 s, 20 m heated line
  • Operating temperature: 20 ± 20 °C, non-condensing
  • Storage temperature: -20 - 60°C, non-condensing
  • Gas cell temperature: 180 °C
  • Sample gas: Non-condensing, particle free
  • Flow rate: ~ 4 liters per minute
  • Sample gas pressure: Ambient
  • Installation place: Dust free and clean ambient air, without external vibrations

Measuring parameters

  • Zero point calibration: 24 hours, calibration with nitrogen
  • (4.0 or higher N2 recommended)
  • Zero point drift: < 2 % of measuring range per zero point calibration interval
  • Sensitivity drift: None
  • Linearity deviation: < 2 % of measuring range
  • Temperature drifts: < 2 % of measuring range per 10 K temperature change
  • Pressure influence: 1 % change of measuring value for 1 % sample pressure change. Ambient pressure changes measured and compensated

Signals (standard)

  • Analog output:
    • Channels: 4 - 20 mA, isolated
    • Output range: 16 freely programmable
  • Analog input:
    • Input range: 4 - 20 mA, isolated
    • Channels: 8 freely programmable
  • Digital output:
    • Output range: 24 VDC
    • Channels: 16 freely programmable
    • System alarm, Service Request, Maintenance, Concentration alarm, Results valid.
  • Digital input:
    • Control: By potential free contacts
    • Channels: 16 freely programmable
    • Probe temp alarm, Zero gas pressure alarm, Cabinet temp alarm, Cabinet cooler alarm, Activate System Standby, Activate span test.

Signals (optional)

  • Up to 255 terminals can be connected
  • Analog output:
    • Output range: 4 - 20 mA, isolated
    • Channels: 4 or 8 channels / terminal
  • Analog input:
    • Input range: 4 - 20 mA, isolated
    • Channels: 1, 4, or 8 channels / terminal
    • Input range: 0 – 10 V, isolated
    • Channels: 8 channels / terminal
  • Digital output:
    • Output range: 24 VDC, isolated
    • Channels: 8 channels / terminal
  • Digital input:
    • Control: By potential free contacts
    • Channels: 4 or 8 channels / terminal

Interfaces (optional)

  • Fieldbus output:
  • Output format: ModBus, ModBus TCP/IP, Profibus, ASCII, DDE link. RS 232 or RS422/485

Industrial computer

See Gasmet Industrial Computer Technical Data Sheet
 
Air conditioning

  • Cooling capacity: A35°C / A35°C 1500 W
  • A50°C / A35°C 1100 W
  • Internal circulation: 500 m3/h

Electrical connections

  • Main supply: 3 x 16 A, 3 x L+N+PE
  • Power consumption: The full Gasmet CEMS II including sample probe and heated lines (21 m) is approximately 7.5 kW

Instrument air

  • Instrument air inlet: 6 mm tube
  • Instrument air quality: Dry, oil and particle free
  • Consumption:
    • 1 l/min with continuous instrument purge
    • 15 l/min with safety flushing (error mode)
    • 50 l/min with waste gas dilution (optional)

Enclosure

  • Material: Bake painted steel
  • Dimensions (mm):
  • CEMS II A
    • 212 x 61 x 70 cm
    • (A/C unit on the cabin roof)
  • CEMS II B
    • 210 x 61 x 113 cm
    • (A/C unit at the back of the cabin)
  • Dimensions H x W x D
  • Weight: ~ 500 kg (full system)
  • Protection:   IP 54