- Model Plus - Personal Air Sampling Pump (1 - 5,000 cc/min)

From

1

Innovation Delivered: The ultimate personal air sampling pump delivering enhanced performance, greater versatility, and superior design and comfort.

  • QuadModeSM Air Sampling Technology
  • Selectable Automatic Fault Recovery
  • Standard Temperature & Pressure Correction
  • Superior Design & Comfort
  • Real-time Clock with Data-logging

The GilAir Plus features wide dynamic flow and pressure ranges to address all personal air sampling methods with flow ranges between 20 and 5,000 cc/min. With patent pending QuadModeSM air sampling technology, the GilAir Plus can perform both high-flow constant pressure and constant flow (450-5,000 cc/min) and low-flow constant pressure and constant flow (20-499 cc/min) with a single pump without external adaptors. It’s like getting two pumps in one.

  • Samples particulates, vapors, gases, and metal fumes
  • Works with all common sampling media
  • Multi-language capability: English, Spanish, French, Italian, Dutch, Portuguese and German
  • Outlet port for bag sampling

Image

GilAir Plus is a smart air sampling pump that provides ambient or standard temperature and pressure corrected display (STP model) and data-logging for up to 16 sampling events (STP and Datalog model). The pump has high back pressure capability of up to 40' H2O in high flow and up to 25' H2O in low flow. An automatic self check system ensures sample accuracy. In the event of a fault condition, the pump’s selectable automatic fault recovery feature attempts to restart the pump up to 10 times every 3 minutes to determine if the fault condition has been cleared.

Image

An intuitive menu, keypad interface and large, easy-to-read back-lit display makes adjusting pump settings quick and easy. Once the pump is set up, the keypad can be locked to prevent tampering. Convenient and innovative SmartCalSM feature provides automatic pump calibration.

Image

One-third smaller than traditional personal air sampling pumps and weighing less than 21 oz. (595 g), the GilAir Plus provides superior operator comfort. An integrated belt clip securely attaches the pump in a horizontal position, allowing workers a full range of motion to perform a wide variety of tasks without interference or discomfort.

Image

The GilAir Plus dock provides charging and communication functions for the STP and data-logging models. Once docked, the PC application allows users to review datalogs, generate sampling reports, manage sampling programs, and create pump set-up profiles that expedite deployment of large pump fleets. The SmartCalSM feature uses the dock as a communication link between appropriate calibration devices and the GilAir Plus. SmartCalSM automates calibration and records pre and post sample calibrations in the pump’s datalog.

When sampling at altitudes of up to 8,000 feet above or 8,000 feet below sea level, GilAir Plus has the capability of automatically correcting the flow rate for altitude changes to maintain constant flow accuracy of +/- 5% over this barometric pressure range. This feature permits GilAir Plus calibration at ground level and sampling at high elevations or deep mines without loss of flow accuracy or the need to calculate and use manual correction factors. GilAir Plus is the only personal air sampling pump with this capability.

Performance

Flow Range
Constant flow 20 - 5,000 cc/min. without external adaptors
Constant pressure 1 - 5,000 cc/min without external adaptors

Flow Modes
Constant Flow or High and Low Flow Constant Pressure

Accuracy

Flow Display ± 5% or 3 cc/min of set flow, whichever is larger

Constant Flow Control ± 5% or 3 cc/min of set flow, whichever is larger

Constant Pressure Control ± 10% of back-pressure

Back Pressure Capability

(8-hour runtime) 5000 cc/min. up to 12” H20 back pressure

4000 cc/min. up to 20” H20 back pressure
3000 cc/min. up to 30” H20 back pressure
2000 cc/min. up to 30” H20 back pressure
1000 cc/min. up to 35” H20 back pressure
450 - 1000 cc/min. up to 40” H20 back pressure
20 - 449 cc/min. up to 40” H20 back pressure

Run Time 8 hour minimum

Flow Fault If flow changes exceed 5% within back pressure specifications, fault notification appears. If fault exceeds 30 seconds, pump shuts down. Selectable automatic fault recovery allows the pump to attempt restart every 3 minutes for up to 10 times or to hold until manual intervention

Environmental

Temperature Ranges

Operating 32°F to 113°F (0°C to 45°C)

Storage -4°F to 113°F (-20°C to 45°C)

Charging 41°F to 104°F (5°C to 40°C)

Humidity Ranges

Operating 5-95 %RH, non-condensing

Storage 5-98 %RH, non-condensing

GENERAL

Display Flow rate, sample time, and sample volume in actual conditions

Controls

Indicators Green and Red LED’s

Dimensions 4.3 x 2.4 x 2.4 inches (10.9 x 6.1 x 6.1 centimeters)

Weight 20.5 ounce (581 grams)

Warranty 2 years from original shipment, 5 years for pump keypad, and 1 year on rechargeable NiMH battery pack

ELECTRICAL

Power Options Removable rechargeable nickel-metal hydride (NiMH) battery pack, optional alkaline battery pack, or DC power

Battery Level Indicator On-screen icon displays battery level

Interface Connectors All pump interface is carried out via the Dock or keypad

Dock Functions Battery charging, computer interface, and auto-calibration

Charging Time Under 3.5 hours

APPROVALS

EN 1232 Compliant Ingress Protection: IP54

Intrinsic Safety

US/Canada NRTL (FM) Class I, Div 1 Groups A, B, C, D, E, F, and G;
Class II, Div 1 Zone 0; Class III, T4

ATEX/IECEx
II 1 G
Ex ia IIC T4

CE

Applicable Directives ATEX 94/9/EC
EMC 2004/108/EC (RFI) LVD 2006/95/EC
RoHS Compliant

Customer reviews