H2scan Hy-Alerta - Model 600B/610B - Fixed Area Hydrogen Monitor
H2scan’s HY-ALERTA 600 Fixed Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount and has an RS422 capability that extends the interface from the sensor to the controller to several hundred feet. H2scan's hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
Specifications
- Sensitivity Range: 0.4% to 5.0% hydrogen by volume, (10% to 125% hydrogen lower flammable limit)
- Accuracy: ± (0.03 x indication + 0.2) percent hydrogen by volume Example: accuracy at 1% H2 is ±0.23% H2
- Typical Response Time: T90 of 60 sec maximum
- Calibration Interval: 90 days
- Calibration Gas Fitting (Model 610B Only): 1/8 inch tube
- Ambient Temperature:
- Operating: -20C to 55C
- Storage: -40C to 80C
- Power Supply: 10-26VDC 10W
- Environmental:
- Indoor/Outdoor Use*
- Altitude up to 2000 meters
- Pollution degree 2 environment
- Ingress Protection: IP64 capable*
- Relative Humidity: 0-95% non-condensing
- Analog Outputs:
- Voltage: 0 VDC to 5 VDC
- - OR -
- Current
- 4 mA to 20 mA
- 650 ohm load resistor max.
- Custom ranges available
- Serial Communications:
- RS-232 or RS-422
- 19200 bps, No parity 8 bit data, 1 stop bit, No Handshaking
- Relay Contacts (Optional):
- Two programmable relays with both normally open (N.O.) and normally closed (N.C.) contacts.
- 1A @ 30VDC SPDT
- One programmable relay with normally closed (N.C.) contacts.
- 1A @ 30VDC SPST
- Dimensions: *Please refer to 600B Manual for drawings and dimensions
- Weight: 0.37 kg (0.82 lb.)