HORIBA - Model TPNA-300 - Automatic Total Nitrogen/Phosphorus Monitoring System
From Process & Environmental - Water Treatment & Environment
Everything from precise measurement to reduced running costs. HORIBA-leading the world in practical environmental analysis technology will give a benefit for Total Nitrogen/Phosphorus monitoring. Total nitrogen, total phosphorus. To measure these two new targets in the 5th of Total Water Contaminants Regulation enforced in Dec. 2001 in Japan, the TPTN-300 offers the ultraviolet oxidation decomposition method that is superior in maintenance and running costs. Not only does the TPNA-300 meet the real need for a precise measurement system, it reduces maintenance time and lowers costs in a variety of ways, from reducing reagent and pure water consumption to decreasing the number of replacement parts. It is a practical system that factors maintenance and running costs into compliance with future standards.
-
Most popular related searches
- total nitrogen monitoring system automatic total phosphorus monitoring system automatic total nitrogen monitoring system phosphorus monitoring system total nitrogen monitor total nitrogen monitoring total nitrogen total phosphorus monitoring automatic total nitrogen monitoring automatic total phosphorus monitoring
Features
- A small footprint makes it possible to store in a case designed for outdoor use. UV monitor (OPSA-120) can also be stored with it.
- Features a built-in pollutant load volume operation function that makes it possible to compute the pollutant load of total nitrogen and total phosphorus from the flow-volume signal.
- Precision measurement is possible even if sea water is mixed with the sample water (optional sea water adjustment function).
- Possible to measure the density of two components, total nitrogen and total phosphorus, at the same time on one monitoring system.
- Using an ultraviolet oxidation decomposition method makes it possible to perform preprocessing at a low temperature (100°C or lower) and atmospheric pressure, which enables much easier maintenance than with traditional autoclave methods.
- High correlation with conventional manual analysis methods.
- Offers a wide variety of functions, such as automated zero-point adjustment and correction.
- Reagents flow by means of a pump. No extra equipment or construction for obtaining an air source for the measurement system is necessary.
Technical Specifications
- Model: TPNA-300
- Name: Automatic Total Nitrogen/Phosphorus Monitoring System
- Measurement methods
- Total nitrogen:
- Alkaline potassium peroxodisulfate UV oxidation - UV absorption method
- Total phosphorus:
- Potassium peroxodisulfate UV oxidation - molybdenum blue absorption method
- Measurement range
- Standard range:
- Total nitrogen: 0 to 2 mgN/L
- Total phosphorus: 0 to 0.5 mgP/L
- One step dilution range:
- Total nitrogen: 0 to 5/10/20/50 mgN/L
- Total phosphorus: 0 to 1/2/5/10 mgP/L
- Two step dilution range:
- Total nitrogen: 0 to 100/200/500/1000 mgN/L
- Total phosphorus: 0 to 20/50/100/250 mgP/L
- Number of measurement ranges
- 1 range (standard)
- *However, 0.2 ≤ total nitrogen full scale/total phosphorus full scale ≤ 100.
- 2 ranges (optional) *Please consult separately.
- Measurement points: 1 point (standard), 2 points (optional)
- Measurement time: 60 minutes
- Repeatability
- Within ±3% full scale (standard range, One step dilution range)
- Within ±5% full scale (Two step dilution range)
- Sample water conditions
- Temperature: 2 to 40°C; Flow rate: 0.5 to 5 L/min (overflow tank flow)
- A sea water adjustment function (optional) is available for when sea water is mixed in.
- *Please consult separately concerning sample water conditions
- Blank water conditions
- Usage volume: 50 L/month *This may increase/decrease depending on the measurement range
- Condition: Should not contain nitrogen or phosphorus compounds
- Fixed pure water tank (standard), continuous supply via pure water supply system (optional)
- Analog output
- Measurement values: Can switch between measurement points and equivalent number
- Load volume: Can switch between measurement points and equivalent number DC4 to 20/0 to 16 mA
- Analog input: Flow rate meter input
- Contact input: Measurement start, Correction start, Forced start, Time adjustment, Flow meter under maintenance, Flow meter damaged, Flow meter power off, Flow meter no waste water, Measurement line selection (2-point metering option)
- Contact output: Measuring line 1 (line 2 optional), Correcting, Standby, Maintenance, Power off, Synchronous signal, Density (max), Warning: Load volume (max), Warning: System failure, No sample water, Insufficient sample water, No pure water, Waste water tank full, No blank water (optional)
- Communications output: RS-232C output
- Power: AC 100 V±10 V 50/60 Hz Approx. 400 VA
- Weight: Approx. 80 kg
- External dimensions: 460 (W) x 425 (D) x 1600 (H) mm
- Paint color: Munsell 5PB8/1 (or equivalent)
- Ambient temperature & humidity: 2 to 40°C, 85% humidity or lower (no condensation)
- Installation environment: Indoors, good ventilation, no direct sunlight.
Customer reviews
No reviews were found for HORIBA - Model TPNA-300 - Automatic Total Nitrogen/Phosphorus Monitoring System. Be the first to review!